Sysmex® CS-2500 System Quality Control Processing Online Training
Perform quality control and use the quality control screen to review, print, and evaluate QC data resulting in comprehensive records for your quality control program. This clinical laboratory training qualifies for continuing education units (CEU).
Identify key areas of the QC chart screen Identify out of control results List the steps to process Quality Control Upon successful completion of this course, you will be able to: The Sysmex® CS-2500 System QC software: Manages QC results for up to 750 assays Stores up to 1,200 data points per assay Displays QC results for each assay on the QC Chart Allows customized settings Identifying Key Areas of the QC Chart Screen Learn about the key areas of the QC Chart screen. Slide NumberText BlocksCalloutsAudio ScriptImage File1Key Areas of the QC Chart Screen To open the QC Chart screen: From the IPU Menu screen, on the toolbar, click the QC Chart shortcut button The QC Chart icon also appears in the View area Select the number to review the corresponding text.Note: If audio does not automatically start, select the play arrow in the top left to begin.CalloutsQC Chart toolbar shortcut QC Chart view area From the IPU Menu screen, select the QC Chart shortcut button on the toolbar. You also can select the icon from the View area. 2Key Areas of the QC Chart Screen Tabs Levey-Jennings (L-J) QC charts Navigation buttons Operation panel buttons Select the number to review the corresponding text. CalloutsQC Chart TabsLevey-Jennings QC ChartNavigation buttonsOperation Panel buttonsKey areas of the QC Chart screen include organizational tabs, QC charts displayed in a Levey Jennings format, up/down and right/left arrows to navigate the QC Chart screen, and operation panel buttons to perform a variety of QC tasks. 3QC Chart Tabs Tabs help you organize QC charts into groups: Customize up to five tabs Define tabs by assigning assays to specific tabs Customize the name of each tab Click a tab to display QC charts to review Select the number to review the corresponding text. CalloutsQC Chart TabsFive customizable tabs are available on the QC Chart screen to organize QC charts into groups to meet the needs of your laboratory’s quality control program. Then, just select a tab to display the group of QC charts that you want to review. 4QC Chart Data Each QC chart displays: QC chart in L-J format Assay name Control name Control lot number Control status: Current or New Chart data: Running statistical data for this chart Select the number to review the corresponding text.CalloutsQC ChartAssay nameControl nameControl lot numberControl statusChart dataAfter a QC analysis, results are charted automatically by date and time and are displayed in a Levey Jennings format. Each chart can display up to 1200 results, which are indicated by a single data point on the QC chart. Each chart is identified by the Assay parameter name, Control name, Control lot number, and Control status. Each assay’s QC target value and standard deviation limits are used to evaluate each QC result. The QC Chart screen displays the calculated Mean target value for each assay as well as upper and lower limits 2 standard deviations from the Mean.5Viewing QC Chart Data Viewing options include: Cumulative data for all results Data for single result Select the number to review the corresponding text. CalloutsChart data areaCursorCursor data areaOn each QC chart, you can view cumulative chart data for all QC results, or you can view details for a single QC result. Use the left and right arrows to move the cursor one data point to view data for a single result. Cursor data for a selected result appears on the right side of the QC chart. 6Viewing QC Chart Data Data point colors: Green data points indicate Current control lot QC results Blue data points indicate New control lot QC results Data points displayed on a QC chart are differentiated by color. Green data points indicate QC results from the Current control lot. Blue data points indicate QC results from a New control lot that is being evaluated.7Viewing QC Chart Data QC errors are indicated by: Red X: QC error Yellow chart: QC result > 2 SD QC results with errors are indicated by color. A red X indicates that a QC error, such as a QC limit or judgment rule violation, has occurred. If the QC chart background color is orange, this indicates that at least one QC result has exceeded 2 standard deviations from the Mean target value. 8Viewing QC Chart Data QC errors are indicated by: Red X: QC error Red chart: QC result >3 SD If the QC chart background color is red, it indicates that at least one QC result has exceeded 3 standard deviations from the Mean target value.9Navigating the QC Chart Screen To navigate the QC Chart screen: Select the single up/down arrows to scroll up or down per page Select the double up/down arrows to scroll up or down per chart Touch inside the chart or use the up/down scroll buttons to select a chart (the selected chart will be outlined in blue) Move the cursor with the left/right arrows or touch the point with the mouse to select a result in the selected chart Select the number to review the corresponding text. CalloutsScroll per pageScroll per chartThe QC Chart screen displays up to four QC charts per page. Use the up/down arrow keys to scroll per page or per chart. 10 Operation Panel Buttons On the QC operation panel: Select an operation panel button to perform a QC task Select More to view additional operation panel buttons When complete, select the X in the upper-right corner to close the window and continue. The QC operation panel displays buttons that allow you to perform functions such as confirming errors, entering targets, or printing reports. Selecting the More button will display additional operation panel buttons. Congratulations. You have completed the Sysmex®CS-2500 System Quality Control Processing Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. List the steps to process QC Automatic QC QC automatically at fixed time intervals QC automatically when aspirating from a new vial of reagent Manual Order Entry from Sample Rack Load QC into specified rack Press Order Select the rack number Press Order Entry Identify the control and lot Select the assays Press OK Press Start Manual Order Entry from the Reagent Table Press Reagent Load SLD mini cup and vial on C-rack onto the reagent table Press Order Press Switch Order Select Holder QC Order Press Order Entry Identify the control and lot number Select the assays Press OK Press Start Identify key areas of the QC Chart screen Sysmex® CS-2500 system software allows you to manage QC results for up to 750 assays, stores up to 1200 data points, display QC results for each assay and customize settings. To access the QC Chart, click the QC Chart shortcut button on the toolbar or the QC Chart icon in the View area. The key areas of the QC Chart screen are: Tabs Organize QC Charts into groups by assigning assays to specific tabs; customize up to 5 tabs by name Levey-Jennings QC Charts Display L-J format, assay name, control name, control lot number, and control status (new or current). The chart data also displays running statistics for the QC chart. Viewing options include cumulative data for all results and data for a single result Navigation buttons Use up/down arrows to scroll per chart or per page. To select a chart, touch inside the chart or use the up/down scroll buttons. To select a result within a selected chart, move the cursor with the left/right scroll button or touch the point with the mouse. Operation panel buttons Click an operation panel button to perform a QC task. Click More to view additional operation panel buttons or Close to return to a previous page of buttons or to close the QC Chart screen. Data point colors and symbols indicate: Current control QC results (green data points) New control lot QC results (blue data points) QC errors are indicated by: QC error (Red X) QC result > 2 SD (Yellow Chart) QC result > 3 SD (Red Chart) Identify out of control QC results Manage QC by using the QC Chart screen to review and print QC data and handle QC errors. To review QC data, open the QC Chart screen and select a QC Chart. Select a data point on that chart. Cursor data area includes analysis result, data and time. Chart Data area includes N = Number of data points used to calculate Mean, SD, CV and Mean, SD, CV To print a QC report, open the QC Chart screen. Press Print Report. Select the parameters and press Print. To document corrective actions for QC Errors on the Help screen, press the Log Corrective Action button. To manage errors, open the QC Chart screen operation panel. QC Charts containing a result with a QC Stop limit are outline in red. QC Charts containing a result with a QC Flag limit are outlined in yellow. To add comments and exclude QC data from automatic calculation use the Confirm Data button on the operation panel. A QC error occurs if a QC analysis result exceeds a QC limit or violates a QC judgment rule. If a QC error occurs, it can be documented on the Help screen as well as in the QC Chart. QC limits include: Flag limit: QC result exceeds 2 SD Stop limit: QC result exceeds 3 SD QC judgment rules include: 1-2s, 1-3s, 2-2s, 4-1s, 5-0.5s, R-4s, 7T, and 10x rules. Handling QC Errors Learn how to handle QC errors. Slide NumberText BlocksCalloutsAudio ScriptImage File1Help screen: Identifying QC Errors The Help screen provides information about the error and includes: Type of error Action messages on how to resolve error Note: If audio does not automatically start, select the play arrow in the top left to begin.When a QC error occurs, the Help screen opens and an alarm sounds. The Help screen displays the error and alerts the operator that a QC Flag limit, Stop limit, or a QC Judgment rule error has occurred. The Help screen lists Action messages to help the operator resolve the error. 2Help Screen: Documenting QC Error Press Log Corrective Action Select a corrective action Enter a comment In this example, a QC Stop limit has occurred. The Help screen allows you to log a corrective action or enter a comment. Simply press the Log Corrective Action button and select a corrective action from the list. If a comment is needed, select Direct entry and type a corrective action in the field provided. 3Help screen: Error Log List of errors Documents User Documents corrective action To view the documented QC error, press the Error log button on the Help screen. The QC error is listed with the time, date, Username, as well as the corrective action taken. 4QC Chart: Find and Document QC Error QC Stop limit: red outline QC Flag limit: yellow outline Select the Confirm Data button from the Operation Panel Select the number to review the corresponding text.Callouts Confirm Data Let's see how a QC error is identified on the QC chart. A QC chart with a QC error is easy to find. QC charts with errors are identified by color. To document the QC error, highlight the QC error result which is indicated by the red X and then press Confirm Data in the operation panel. 5QC Chart: Confirming QC Errors To confirm a QC error: Enter a comment in the Detailed Data dialog box Check Exclude from Automatic Calculation if QC result should be excluded Select Update When complete, select the X in the upper-right corner to close the window and continue. On the Detailed Data dialog box, you can review chart information such as the assay name and control lot number as well as the analysis result and the type of QC error that has occurred. Enter a comment in the field provided to indicate a corrective action or add initials. Following your laboratories protocol, it may be necessary to exclude the point from calculation. Check the Exclude from Automatic Calculation box to perform this action. Welcome to the Sysmex® CS-2500 System Quality Control Processing Online Training course. Monitoring Quality Control: Confirms reliable results Monitors instrument and reagent conditions Allows analysis and management of control results QC processing options: Automatic QC Manually order QC from a sample rack Manually order QC from the reagent table The Sysmex® CS-2500 System allows users to manually run QC in a sample rack using a 4mL cup. Manual order from sample rack Learn how to run QC from a sample rack. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90015070/sim_CS25_QCOLT_Sim1_ManualEntrySampleRack_1290x725/sim_CS25_QCOLT_Sim1_ManualEntrySampleRack_1290x725.swfHTML5 File:/content/generator/Course_90015070/sim_CS25_QCOLT_Sim1_ManualEntrySampleRack_1290x725/index.htmlPDF File: Quality Control can also be processed from onboard the Sysmex® CS-2500 System using a SLD mini cup and specialized reagent rack. Manual Order Entry from the Reagent Table Learn how to order QC from the reagent table. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90015070/sim_CS25_QCOLT_Sim4_ManualEntryReagentTable_1290x725/sim_CS25_QCOLT_Sim4_ManualEntryReagentTable_1290x725.swfHTML5 File:/content/generator/Course_90015070/sim_CS25_QCOLT_Sim4_ManualEntryReagentTable_1290x725/index.htmlPDF File: SLD mini cup Learn about using a SLD mini cup and C-rack. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90015070/sim_CS25_SLDMinicup_1290x725/sim_CS25_SLDMinicup_1290x725.swfHTML5 File:/content/generator/Course_90015070/sim_CS25_SLDMinicup_1290x725/index.htmlPDF File: The Sysmex® CS-2500 System alerts the operator whenever the Quality Control results fall outside of acceptable ranges. QC Flag Limits: alerts operator that QC results exceed the flag limits QC Stop Limits: interrupts processing and alerts operator that QC results exceed the stop limits Out of Control Results Learn how to identify out of control results. Select each tab below to learn about identifying out of control results.TitleTextStop LimitTab TitleTextHelp Screen QC Stop Limit: Indicates the results of quality control analysis exceeded the upper or lower stop limit. The Help screen appears with an audible alarm. The Help screen lists corrective action steps to use in resolving the error. Operators can enter a corrective action for the QC error which then is displayed in the error log. QC Chart The QC Chart screen: The software displays a QC Stop Limit error by changing the background color of the chart to red and analysis stops. Flag LimitTab TitleTextHelp Screen QC Flag Limit: Indicates the results of quality control analysis exceeded the upper or lower flag limit. The Help screen appears with an audible alarm. The Help screen lists corrective action steps to resolve the error. The Operator can enter a corrective action for the QC error which is then displayed in the Error log. QC Chart The QC Chart screen: The software displays a QC Flag Limit error by changing the background color of the chart to yellow and analysis continues. QC can be run automatically by the Sysmex® CS-2500 System: At fixed time intervals When aspirating from a new vial of reagent Automatic QC Learn about changing settings to perform Automatic QC Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90015070/sim_CS25_AutoQCSettings_1290x725/sim_CS25_AutoQCSettings_1290x725.swfHTML5 File:/content/generator/Course_90015070/sim_CS25_AutoQCSettings_1290x725/index.htmlPDF File:
- sysmex
- sismex
- sysnex
- cs25
- 2500
- cs2500
- cs-2500
- qc
- quality control