Sysmex® CS-5100 System Hemolysis and Lipemia Check Job Aid
This job aid provides instructions on how to view hemolysis and lipemia check results from various software screens on the Sysmex CS-5100 System.
Sysmex CS-5100 System Hemolysis and Lipemia SIEMENS Healthineers Check Viewing the HL Check Results 1 1. Press Joblist from the IPU toolbar or menu screen. Menu Reagent Calib. Curve QC 2 Order Joblist Status Maint. Shutdown STAT Stop Start 2. View the Sample Info. column. Status Rack No -Pos. Sample No MO de Sample Info. Comment F V Date Start End PT INN sec TT Thr sec Order Entry Time R Time sec sec 000002-04 615n-15m-4 N M F V 2016/11/09 15:07 15:14 11.6 Described below are the possible HL Check 000002-05 615n-15m-5 N M F V 2016/11/09 15:08 15:14 11.5 Browser 4 000001-01 612n-15m-1 N M Hem F V 2016/11/09 15:23 15:30 11.5 results 000001-02 612n-15m-2 N M Hem F V 2016/11/09 15:23 15:30 11.5 000001-03 612n-15m-3 N M Hem 15:30 Validate - F V 2016/11/09 15:24 11.5 • Hem – flag for hemolysis 000001-04 612n-15m-4 N M Hem F V 2016/11/09 15:24 15:31 11.5 Lip – flag for lipemia 000001-05 612n-15m-5 N M Hem F V 2016/11/09 15:24 15:31 11.6 Display Conditio • Review 000001-01 615n-12m-1 N M F V 2016/11/09 15:39 15:45 **** * H* interference in Hemolysis reading 000001-02 615n-12m-2 N M F V 2016/11/09 15:39 15:46 • ****.* Find Review 000001-03 615n-12m-3 N M F V 2016/11/09 15:40 15:46 ****.* Check tube manually Review 000001-04 615n-12m-4 N M F V 2016/11/09 15:40 15:46 ***** Review 000001-05 615n-12m-5 N M • L* interference in Lipemia reading F V 2016/11/09 15:40 15:47 ***** Review 000001-01 711m-0- N M Hem Lip F V 2016/11/24 08:42 08:49 ***** Check tube manually Review 000001-02 711m-0-2 N M Hem Lip F V 2016/11/24 08:43 08:49 * ***** 3 Review 000001-03 8789 N M Lip - F V 2016/11/24 08:43 08:50 ***** Review 000001-04 711m-0-4 N M Hem Lip - F V 2016/11/24 08:43 08:50 ****** 3. Select the appropriate Sample No. line to Review 000001-05 711m-0-5 N M H* L* - V 2016/11/24 08:44 08:50 ***** Review 000001-01 70-111-1 N M F V 2016/11/24 08:59 09:06 More view additional sample integrity information. 10.7 (1/3) Review 000001-02 70-111-2 N M F V 2016/11/24 09:00 09:06 10.7 Review 000001-03 70-111-3 N M F V 2016/11/24 09:00 09:06 10.7 4. Press Browser on the operation panel. A A A List Close X 1 HOOD05162002626381 © Siemens AG 2013. All rights reserved. Page 1 Effective date: 7/18/2017 Sysmex CS-5100 System Hemolysis and Lipemia SIEMENS Healthineers Check Browser Main X Viewing the HL Check Results Menu Reagent Calib. Curve QC Chart Order Joblist Status Maint. Shutdown STAT Stop Start 5. On the Browser Main screen press Detail. Processing Fina The Detail dialog box displays the results of the HL Check. Ham 6. Ict A HOST No 8789 2017/04/28 10:25:12 Not Validated Lip Vol # 000004-01 Up • [Hemolyzed Sample] Routine Lot Roll More PT PTT Down • [Lipemic Sample] PT * ***** INR sec PTT * ***** sec 7 * ***** Press the reaction curve graph. 5 Validate 7. Dilution Ratio 1 / 1 Dilution Ratio 1 / 1 Detail Detail Print Detail X Sample No. 8789 M PT HC Output Result Assay Group Value Units ***** sec A INR * ***** More Information (1/2) Code Content 6 0032.0000.0000 No Coagulation 1000.3000.0000 Lipemic Sample Close X A Close 10:34 2 HOOD05162002626381 © Siemens AG 2013. All rights reserved. Page 2 Effective date: 7/18/2017 Sysmex CS-5100 System Hemolysis and Lipemia SIEMENS Healthineers Check Viewing the HL Check Results Reaction Curve 8. Select the Measurement Info tab to display the flagging level value. Menu Reagent Calib. Curve QC Chart Order Joblist Status Maint. Shutdown Stop Start STAT Sample No. 8789 M Date/ 2016/11/14 07:31:48 Detail Time Result Assay Group PT-INN Assay Group Value Units PT INN sec **** * sec Up 4000 3600 8 Down Zoom In 3200 Clotting Point Evaluation Info Evaluation Data Measurement Info 2800 Print Zoom Measurement Info Out 2400 Name Value 2000 Temperature 37.0 1600 | Channel No. 2 Management ID 1023 1200 Reagent Lot PT Inn:539306 800 Dilution Ratio 1 /1 400 Elapsed Time PT Inn:O lem Detection Level 10 20 30 50 60 [sec Ict Detection Leve Lip Detection Level 0 Vol Detection Leve Auto Scale Zoom Zoom Calibration Curve ID Out In QC Performed Date Close X Reagent Table Temp. 9.5 3 HOOD05162002626381 © Siemens AG 2013. All rights reserved. Page 3 Effective date: 7/18/2017
- cs5100
- cs51
- 5100
- cs-5100
- sysmex
- sismex
- sysnex