Sysmex® CS- 5100 System Multiple Dilution Analysis Video
This video provides instructions on how to order and review Multiple Dilution Analysis results on the Sysmex CS-5100 System.
In this simulation we will learn how to order an review results using the multiple dilution analysis MDA method. To begin press order from the Ipiu toolbar or menu screen. On the upper right hand side of the order screen, specify the rack number, then press order entry on the Operation Panel. Under the Ordinary Sample tab, enter the sample number and select the appropriate factor assay. Press OK. To select the desired MDA dilution ratios, I like the ordered sample number. Press detailed settings on the Operation panel. Under the dilution ratio column, press the one to one key. Select the appropriate MDA dilution ratio. Press OK from the detailed settings dialog box. Press start from the Ipiu toolbar or main unit button to begin analysis of the sample. To view MDA patient results, press job list on the Ipiu toolbar or menu screen. On the job list screen, find the sample number displaying the MDA results and the corresponding mean to view the reaction curve, select the line displaying the mean result and press browser from the operation Panel. Here the browser main screen displays the reaction curves, analysis results and reference information from the selected line on the job list screen. To display detailed information for each dilution press on the reaction curve in the reaction curve display area. Here, individual dilution results in additional reference information for the specific assay is displayed. If an error were to occur during analysis, the detail button appears highlighted on the browser screen. Press detail to find additional information about the error code. Congratulations, you have completed this exercise.
SS ISI ISI IS LAV St Start STAT Point 02/22/2017 0826.18 Final Unregistered Chancel Rack Changel Cancel 00222/2017 HOST 1193 189 E 000003-01 Validated pos. Sample Sample NO. 2017/04/28 co 40 1125 Sample sample Lot Roll More n e Edit Sample Info. 2017/04/28 051 189 11564 258 STAT Re high y G roup O roup Red Dilution Ratio Red 85241 VU—INN 2017/04/28 1325 1025 P r g IS 0000000300m E 000003-01 VIE I VII I '18.1 SO St Congratulations. You have completed this exercise. 11 85241 10 SO 11 ALPH Entery 0K OK Changel Operation LA R_ LA R_ Pc AT AT LA R- LA LA R- LAV 0K OK Change Changel Chancel Lab OFF 11 : 26 120s 1193 11 '26 11 .26 10 11 1125 : 26 11 '24
- cs5100
- cs51
- 5100
- cs-5100
- sysmex
- sismex
- sysnex