Sysmex® CS-5100 System Sample Processing Online Training
Create work orders, process samples, and identify sample status for accurate and timely patient results using the Sysmex® CS-5100 system Reagent screen software. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the Sysmex® CS-5100 System Sample Processing Online Training course. The steps to process samples include: Load samples in a rack Order tests manually or by Host Computer Press Start Select Next to continue. Identify and resolve three common sample processing errors Identify areas of the Order screen List the steps required to process samples Upon successful completion of this course, you will be able to: Select Next to continue. Scan parameters for children and adult protocols alike can be found on the Routine and Scan subtask cards in every protocol. The default parameters are of course subjective – you will typically adapt the Siemens defaults to meet the specific scanning needs of your facility and your physicians. Then, you can re-save the protocol with a different name as your own customized examination. Several features here – specifically CARE Dose4D and CARE kV – help to optimize the dose for each individual patient, meaning that critical dose parameters do NOT need to be modified on a patient by patient basis. This serves to enhance scanning workflow, enable scanning consistency – and automate the dose optimization process. Let’s take a closer look at these innovative dose reduction features. Congratulations. You have completed the Sysmex® CS-5100 System Sample Processing online training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Identify areas of the Order screen Sample Rack number entry Navigation of the Operation Panel Switch Order used to change order screens for sample rack, calibration and quality control Repeat function to duplicate tests ordered Order Entry to manually enter sample number and order tests Detailed Settings to order additional or specialized sample processing List the steps required to process samples Verify reagent availability Check usable volume Check number of tests Check elapsed time Processing with a Host Computer Interface Check the Host Computer status Load samples into a rack Press Start Processing manually with barcoded samples Identify the sample rack Order tests for each sample Load samples into the identified rack Press Start Processing manually with non-barcoded samples Identify the sample rack Identify each sample Order tests for each sample Load samples into the identified rack Press Start Processing samples in Micro-sample mode Identify the sample rack Request sample be processed Micro-sample mode Identify sample in Order Entry Order tests Uncap sample, place in identified sample rack and process Common Errors encountered during sample processing Insufficient Sample Sample Barcode Read Error Rack Barcode Read Error Select Next to continue. CARE Dose4D allows for optimized dose delivery and consistent image quality because it customizes how the prescribed mAs is adapted for each patient. Dose is modulated in real time as the tube rotates around the patient and as the patient moves through the gantry - X, Y AND Z-axis modulation - specific to the current patient’s size and to the thickness of the area being scanned. This allows for a scan protocol to be used across all types of patients, without having to make hasty decisions or on-the-fly parameter changes for each study. The Order screen is used to: Order samples Order QC Order a calibration Request Micro Mode Identifying the Areas of the Order Screen Learn how to navigate the Order screen. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90006254/sim_CS51_OrderScreenNavigation_800x600/sim_CS51_OrderScreenNavigation_800x600.htmHTML5 File:/content/generator/Course_90006254/sim_CS51_OrderScreenNavigation_HTML5_800x600/index.htmlPDF File: With the advent of two-tube, two detector CT systems – Dual Source Scanners – Siemens has revolutionized the way that CT images can be acquired, processed, and interpreted. Aside from Dual Energy and Dual Power functionality, the ability to scan with twice the hardware can significantly reduce the time it takes to scan some patient examinations. Siemens’ Flash Spiral modes are yet another tool in the portfolio of dose reduction options, and are especially helpful for reducing dose in children. In this section we will cover how to: Verify reagent availability Process samples when connected to a Host Computer Manually process barcoded samples Manually process non-barcoded samples Order samples in Micro-sample Mode Select Next to continue. To process samples while connected to a host interface: Check Host Computer status Load barcoded samples in a rack Press Start Processing with a Host Computer Interface Learn how to process samples with a Host Computer Interface. Checklist TitleChecklist TypeChecklist ContentCheck Status of Host ComputerHTML Status of communications between the Sysmex® CS-5100 System and the Host Computer is displayed on the Status Bar. Color Status Green Connecting Red A communication error has occurred Space The setting of the instrument indicates the host computer will not be used Select each checkbox to learn more about processing samples with a Host Computer Interface Load Barcoded Samples in RackHTML Load samples into a sample rack with barcode label aligned with the slit in sample rack. Press StartHTML Place the sample rack in the right rack pool positioning the notch on the side of the sample rack to the right and align it to the rack guide in the right rack pool. Press Start to begin processing. When complete, select the X in the upper-right corner to close the window and continue. Al término de este curso, usted estará en la capacidad de realizar: El mantenimiento semanal El mantenimiento mensual El mantenimiento según necesidad Seleccione Siguiente para continuar. To manually process barcoded samples: Identify the sample rack Order tests for each sample Load samples into the identified rack Press Start Manually processing with barcoded samples Learn how to manually process barcoded samples. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90006254/sim_CS51_ManualBarcodedSamples_800x600/sim_CS51_ManualBarcodedSamples_800x600.htmHTML5 File:/content/generator/Course_90006254/sim_CS51_ManualBarcodedSamples_HTML5_800x600/index.htmlPDF File: To manually process non-barcoded samples: Identify the sample rack Enter sample identication Order tests for each sample Load samples into the identified rack Press Start Processing Manually with Non-barcoded Samples Learn how to manually process non-barcoded samples. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90006254/sim_CS51_ManualNonBarcodedSamples_800x600/sim_CS51_ManualNonBarcodedSamples_800x600.htmHTML5 File:/content/generator/Course_90006254/sim_CS51_ManualNonBarcodedSamples_HTML5_800x600/index.htmlPDF File: To process samples in Micro-sample Mode: Identify the sample rack Press the Mc column Press Order Entry on Operation Panel Enter sample number Order tests Load uncapped samples into the identified rack Press Start Processing Samples in Micro Sample Mode Learn how to process samples in Micro Sample Mode. Checklist TitleChecklist TypeChecklist ContentIdentify sample rackHTML Enter the Sample Rack Number Select each checkbox to learn more about sample processing in Micro Sample Mode Press the Mc columnHTML Press the Mc column Press Order EntryHTML Press Order Entry Enter Sample numberHTML Enter the sample number. Order testsHTML Order tests requested and press OK to save request. Load uncapped samples into sample rackHTML Load samples in sample rack. Note: All samples must be uncapped when processing in micro-sample mode. Press StartHTML Press the Start button on Main Unit to begin processing When complete, select the X in the upper-right corner to close the window and continue. It is important to check your reagents before processing samples. Check usable volume Check number of tests Check elapsed time Verify Reagents Learn how to check the reagents availability. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90006254/sim_CS51_CheckReagents_800x600/sim_CS51_CheckReagents_800x600.htmHTML5 File:/content/generator/Course_90006254/sim_CS51_CheckReagents_HTML5_800x600/index.htmlPDF File: Select each tab to learn about common errors encountered during samples processing. Indicator of an Error: Audible alarm and IPU displays Error Help dialog box Probable Cause The sample volume is insufficient The sample is not set in rack The sample adheres to the back of the tube cap The liquid surface sensor has failed Corrective Action Check the sample volume Verify sample is not adhered on the back of tube cap Set the sample with the required volume in sample rack and reanalyze If errors persists, contact Siemens Technical Solutions Center Indicator of Error: Sample No displays as ERR00000000 on Joblist Probable cause The anti-rotation holder is damaged or not attached The barcode label is dirty Corrective action Verify the sample barcode label is correctly placed in rack Check the condition of the barcode label Check the results on the joblist and reanalyze sample If error persists contact Siemens Technical Solutions Center Indicator of Error: Audible alarm and IPU displays Error Help dialog box Probable cause The rack barcode label is dirty The rack barcode label does not meet specification The rack barocde label is not affixed or has peeled off The sample barcode scanner has failed or is dirty Corrective action Check the sample rack barcode label Check the analysis order in the joblist If errors persists, contact Siemens Technical Solutions Center Select Next to continue.