Sysmex® CS Systems Lot Rollover Checklist
This checklist provides a guide for users as they complete lot rollover.
Lot Rollover Checklist Sysmex® CS Systems Reference Interval verification Establish MNPT value Establish QC ranges – Print PTN and PTTN QC points (minimum 30 points each) Perform lot-to-lot method correlation Print QC data for current PT QC Print QC data for current aPTT QC Enter new QC lot numbers into Reagent Lot Master Input new PT reagent lot and expiration date in Reagent Lot Master Input new aPPT reagent lot and expiration date in Reagent Lot Master Change Lot: for new Ci-Trol 1 (PTN, PTTN, Fbg, PT, PTT) This step enters new QC range for PT, PTT using PTN and PTTN statistics Change Lot: for new Ci-Trol 3 (PTN, PTTN, Fbg, PT, PTT) This step enters new QC range for PT, PTT using PTN and PTTN statistics Input new PT Normal Value (MNPT) and ISI and validate LIS: Make changes as needed Run QC for PT and PTT Heparin Therapeutic Range study for new lot PTT reagent SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Healthineers Effective Date: 03/25/2019 | HOOD05162003001220 Checklist | Lot Rollover Effective Date: 03/25/2019 | HOOD05162003001220 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 2
- cs5100
- cs51
- 5100
- cs-5100
- cs2500
- cs25
- 2500
- cs-2500
- cs 5100
- cs 2500
- sysmex
- sismex
- sysnex
- sizmex
- syzmex