Table Positioning Strategies - Numaris X

The Table Positioning Strategy Job Aid defines ISO, Local Range, and FIX Strategies.  It also provides guidance and applications used on Numaris X software.

Table Positioning Strategy’s – Numaris X Job Aid Table Positioning Strategy’s – Numaris X During patient registration, the system is initialized with one of the three positioning strategies that will remain valid for the entire examination. The default positioning strategy depends on the selected Body Part and the measurement program. In case of a multi-study examination, the initial requested procedure (examination) determines the default strategy. The toolbar of the program control displays the positioning strategy that is currently active.  Table Positioning Strategy’s: ISO, Local Range, FIX  During Examination, selected positioning strategy can be changed using the “Table Positioning Strategy” step if measurement of preceding protocols was completed.  Slice planning is only performed on DIS2D or DIS3D Distortion Corrected images, no unloading of images from GSP.  GSP can only display distortion corrected images (e.g., exception Spectroscopy).  Global Table Positioning Strategy setting is located at the Region, Exam, or Program level in the Dot Cockpit under Edit Properties.  Table Positioning Strategy – always displayed top of Measurement Queue 1. Iso Center (ISO) – (e.g., Default Strategy) a. ISO table position calculated so measurement is performed at Isocenter i. Based on center point of all slice groups ii. Like “Scan Region Center” or “Scan at Center” b. Table moves to “Iso Center” of Slice/Slab Group after sequence is applied c. Set-n-Go Protocols always use ISO (e.g., Default) d. Applications – Larger anatomical regions (e.g., Spine, Abdomen, Pelvis, Long Bone) Brain Dot Engine ISO ℮ + 1 AAhead_scout 2 11_qtse_dark-fluid sag_p2 Table Positioning Strategy Select Table Positioning Strategy Iso Center Local Range Fixed Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/16/2020 | HOOD05162003093649 Healthineers Job Aid | Table Positioning Strategy’s Job Aid Effective Date: 06/16/2020 | HOOD05162003093649 2. Local Range (LOC) a. LOC is based on an examination-specific FoV Area and a Focus Position defining the center of the FoV/Slices in the z-direction. i. Slice groups within FoV/Slices Area are measured without repositioning the Patient Table b. Center of LOC Range – Defined by Light Marker Position (or) Reset Table Position c. Local Range Tolerance Criteria i. Slice/Slab Groups are Positioned “within” Tolerable Local Range – table doesn’t move to perform the measurement. ii. Slice/Slab Groups are NOT Positioned “within” Tolerable Local Range (slices too far from isocenter) – measurement is executed at ISO-center position and table moves. d. GSP Segments – small triangle indicates current Focus Position i. Define the Local Range Center Position by dragging the Yellow Triangle in the planning segment(s) to the body part. (OR) ii. Select one of the “Previously Used Positions” or “Enter a Position” in the Local Range Position Field. e. Applications i. Smaller anatomical regions (e.g., Head, Knee, Heart, or when table movement is not needed) Brain Dot Engine LOC + HAL Test Brain 112342 AAhead scout 5 IKA 1 FRM 15/29 11_gise_dark-fluid sag p2 Table Positioning Strategy Select Table Positioning Strategy ARF Iso Center Local Range Fixed Define Local Range Center Position by dragging the triangle in the TP 0 planning segment(s) to the body part of interest SP.RO 7 Fov 220*220 Cor(3)-Tra(1) p2 MAGN/NORMDIS2D W 1188 11_qtse_dark-fluid_sag_p2 529 K Alternatively select one of the previously used positions or enter a particular position Local Range Position H 0 mm Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 5 Job Aid | Table Positioning Strategy’s Job Aid Effective Date: 06/16/2020 | HOOD05162003093649 3. Fixed (FIX) a. Fixed performs all measurements at a set table position (e.g., Table doesn’t move) i. Table remains in a fixed position even if the slice/slab group is placed out- side isocenter. b. GSP Segments – small triangle indicates the Fixed Table Position i. Note: The Fixed Table Positioning Strategy allows imaging outside of the homogeneity sphere, beyond the isocenter of the scanner. ii. This strategy may result in poor image quality if prescribed too far from isocenter. c. Applications i. Interventional Workflow (e.g., Biopsy, Ablation Exams). Brain Dot Engine FIX HAL Test Brain 112342 AAhead_scout 5 IKA 1 FRM 15:29 2 11_qtse_dark-fluid sag_p2 3 12 qtse_tra p3 4 % Table Positioning Strategy ARF Table Positioning Strategy Select Table Positioning Strategy TP 0 SP.RO 7 Iso Center Fov 220*220 Local Range Con(3)-Tra(1) p2 MAGNINORMDIS2D W 1188 11_qtse_dark-fluid_sag_p2 The Fixed Table Positioning Strategy allows for imaging outside of the homogeneity sphere, beyond the isocenter of the scanner. Selecting this strategy can result in poor quality images, use only if needed Check the operator manual for further information. Confirm and Proceed Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 5 Job Aid | Table Positioning Strategy’s Job Aid Effective Date: 06/16/2020 | HOOD05162003093649 4. Changing Positioning Strategies During an Examination a. No sequence running b. Select a Sequence not Executed in Queue i. Right Mouse select Insert Table Positioning Strategy ii. Select either Iso Center, Local Range, or Fixed iii. Select GO Brain Dot Engine LOC Y + Table Positioning Strategy Test Brain AAhead_scout 142342 5 IMA1 FRM t1_qtse_dark-fluid_sag_p2 Select Table Positioning Strategy 3 %_ 12_qtse_tra_p3 Append Insert so Center Local Range Fixed x_ 12_qtse_dark-fluid_tra Append Pause. Ctrl+insert 5 % resolve_3scan trace_tra Insert Table Positioning Strategy Define Local Range Center Position by dragging the triangle in the planning segment(s) to the body part of interest H_mprage sag p2 iso Repeat 9 7 MPR planning Repeat and Open Rerun from here t1 012d tra Rerun from here with Copy Parameters .. Update Copy Reference O KX Remove Copy Reference Alternatively select one of the previously used positions or enter a particular position Delete Skip Cut Ctrl+X Local Range Position H 0 mm Copy Ctrl+C Paste Ctrl+v Delete Del Clear All Shift+Del Save as .... Ctrl+S Edit Properties ... Alt+Enter Brain Dot Engine LOC " Y + AAhead_scout 2 11_qtse_dark fluid_sag_p2 D 3 Table Positioning Strategy 4 12 qtse tra p3 01:31 5 x_ 12_qtse_dark-fluid tra 04:14 6 % resolve 3scan trace tra_p2 160 01:46 7 %_ 11_mprage_sag_p2_iso 05:21 % MPR planning 9 X 11 f12d tra 01:19 E 14:11 Delete Skip Go Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 5 Job Aid | Table Positioning Strategy’s Job Aid Effective Date: 06/16/2020 | HOOD05162003093649 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 5 of 5