MR View&GO TimeCurve - Numaris XA31

This Job Aid reviews how to use TimeCurve to evaluate dynamic data sets and signal changes over time.

MR View&GO – TimeCurve Job Aid syngo MR Systems with Numaris X TimeCurve can be used to evaluate dynamic data sets to show signal changes over time. The output of such an evaluation is a time curve that plots the intensity of the contrast media over a certain time-period. TimeCurve can be used for test bolus scanning or lesion evaluation in dynamic scans. All dynamic series must be run in one sequence to use the TimeCurve.  Note: Image data must be classified as 4D to be able to load into TimeCurve 1. Viewing Step of MR View&GO, select images for TimeCurve post-processing 2. Favorite Tools area, select TimeCurve icon to load images into TimeCurve Case Navigator Favorite Tools X 3D O Show in TimeCurve ADC & b- Composel 30 value Combine  New Window Opens with two segments  Dynamic Series loaded into Left Segment  TimeCurve is eventually displayed in Right Segment  Scroll to Different Phases of Series  Depress Right-Mouse > Move Mouse Right/Left on keyboard (or) use 4D +/- but- ton on keyboard MR View&GO AF MR View&GO Stack 3x2 Stack 2x2 Suck 3x4 View&GO Dataset St. Georg Klinikum TC1 Normal Time: 20.84 sec Mean: 33.11 Ratio: 45.3 % 123456789 an (%) *1/28/1991, M. 30Y MAGNETOM Altea MR XA11 50 CURRENT HFS 12/19/2018 .LPH Carotids_Test Bolus latest/Phase_22 of 60 Favorite Tools · TimeCurve STUDY ID cd328ed3-1ea6-45 11:19:42 AM O 8 IMA 22 FRM 1/1 TC-Circle TC-Pocol TC TC Lens Freehand Snapshot TC1 Min / Max 15.00 /47.00 Mean/SD: 33.11 /7.80 Series Area: 0.90 cm2 Sum: 2781.00 84 Pixels Printing Favorite Tools X Show in TimeCurve ADC & b- Composel 30 value Combine New Composition SL 22.0 F 3D Ref. Distance Position Snapshot TR 43.1 Point Line Displa ... TE 1.8 TP F141 TA 00.98 SP F139.0 R A BW 322.0 FOV 175*200 Flip Save as Mosaic Subtracti. MAGNIANGIO/NORM/DIS2D 155*192 Horizontal Series Tra>Cor(9) A1/SAT2 Zoom 3.43 NE1,2,SP1 W 126 O 10 15 20 25 "12d1_7 / 25 C 48 Time Offset: 0 sec Normal Time (sec) + TTC 21.3 se Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/28/2021 | HOOD05162003208202 Healthineers Job Aid | MR View&GO – Time Curve Effective Date: 07/28/2021 | HOOD05162003208202 3. ROI/Pixel Lens/Freehand Tools  Scroll through Series to find Correct Timepoint to Draw ROI  Select Tool from TimeCurve Case Navigator o TC-Circle o TC-Pixel Lens o TC-Freehand TimeCurve X O L TC-Circle TC-Pixel TC- TC- Lens Freehand Snapshot  Draw an ROI around Area-of-Interest on image STUDY ID cd328ed3-1ea6-45 11:19:39 AM 8 IMA 19 FRM 1/1 TC1 Min / Max: 11.00 /47.00 Mean/SD: 34.21 /9.02 Area: 0.87 cm2 Sum: 2668.00 78 Pixels R 10cm SL 22.0 F Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/28/2021 | HOOD05162003208202 Healthineers Page 2 of 5 Job Aid | MR View&GO – Time Curve Effective Date: 07/28/2021 | HOOD05162003208202 4. TimeCurve Evaluation  Graph appears in Right Segment  X-Axis of Graph  TI Scout Evaluated – displays Trigger Time in milliseconds  All other Sequences – Toggle X-Axis values between Normal Time (or) Image Number  Lower Right Segment > Left-Click Blue Interactive Text to Toggle be- tween two displays  Navigate through Graphs or Images to find Specific Time Points TC1 Normal Time: 12.9 sec Mean: 13.17 Ratio: -42.75 % Mean (%) TC1 Mean (%) Image No.: 14 Mean: 13.17 Ratio: -42.75 % 50 50 25 -25 -25 -50 50 -75 75 25 O 5 10 15 30 10 15 20 25 30 35 O Time Offset: 0 sec Normal Time (sec) Image No. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/28/2021 | HOOD05162003208202 Healthineers Page 3 of 5 Job Aid | MR View&GO – Time Curve Effective Date: 07/28/2021 | HOOD05162003208202 5. Adjusting Time Offset  Left-click Time Offset to open Time Offset Window  Can be used to automatically begin a timing bolus sequence at a specified time  Enter Time Offset > select OK Time Offset ? X 5 Time Relative to Start of Scan Time Offset: 0 sec Time Offset 0.0 sec -10 sec = 10 seconds after start of scan +15 sec = 15 seconds prior start of scan OK Cancel 6. Taking a Snapshot  TimeCurve Case Navigator > select TC-Snapshot – saves a snapshot of Graphs and ROIs TimeCurve X O TC-Circle TC-Pixel TC- TC- Lens Freehand Snapshot  Results Saved in Series List MR, 1/28/2021 View&GO Dataset 8 Carotids_Test Bolus 10 ... : Results Time Curve Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/28/2021 | HOOD05162003208202 Healthineers Page 4 of 5 Job Aid | MR View&GO – Time Curve Effective Date: 07/28/2021 | HOOD05162003208202 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/28/2021 | HOOD05162003208202 Healthineers Page 5 of 5