Transporting the C-arm - Cios Flow & Cios Fusion
This video demonstrates how to transport the c-arm for both the Cios Flow and Cios Fusion mobile c-arms.
Welcome to the system transport video. In this video you will learn how to transport the CRM system. Please note we perform all steps on a CS flow CRM system. All shown steps can be performed on eseos Fusion CRM system as well. First, disconnect the foot switch from the C arm if applicable and store the footswitch into the footswitch Holder on the back of the CRM system. Roll up the cable onto the Holder if applicable. Move the C arm system to the transport position by setting the C arm to the zero degree angular. An zero degree orbital position. Move the horizontal support arm all the way back. By using the orange brake swivel, the C arm to the zero degree position. Move the lifting column of the C arm to its lowest position by pressing the down button on the control unit. When all components of the CR man, the Monitor Trolley are in the transport position, you can shut down the system, close the current patient and press the off button on the monitor trolley. And to remove the connection cable, turn the central plug switch to the left until it is in the vertical position and disconnect the plug from the socket. Disinfect it and roll it up on the side handle of the monitor trolley. Ensure that the plug does not touch the floor and that the connection cable is secure on the side handle. To transport the CR, Press the release button on the steering lever and pull the lever up. The indicator changes to green. You can now transport the C arm using the handles. Avoid transporting the C arm on surfaces with an incline which is greater than 5 degrees and ensure that there are no obstructions on the path. When you have positioned the C arm in the room, lock the brake by pressing the button and lifting the steering lever. The indicator changes to red.
10 The reproduction, transmission or distribution of this training or its contents is not permitted without @ Siemens Healthcare GmbH, 2020 express written authority. Offenders will be liable for damages. Please note that the learning material is for training purposes only! All names and data of patients, parameters and configuration dependent designations are fictional and 10 cm examples only. SIEMENS . For the proper use of the software or hardware, please always use the Operator Manual or Instructions for 10 Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used Cios Flow, Cios Fusion All rights, including rights created by patent grant or registration of a utility model or design, are reserved. as training material only and shall by no means substitute the Operator Manual. Any material used in this SIEMENS . training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. 30 Healthineers The Operator Manual shall be used as your main reference, in particular for relevant safety information like 10 System Transport Part 1 - Transporting the C-arm warnings and cautions. 10 cm SIEMENS Note: Some functions shown in this material are optional and might not be part of your system. SIEMENS Healthineers Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. Healthineers
- cios flow
- cios fusion
- mobile
- c-arm