Troubleshooting the Atellica® Sample Handler Connect Online Training Version 1.25 and Below
This online training describes how to perform the tasks involved in troubleshooting the Atellica® Sample Handler Connect.
NOTE: This course does not include an assessment.
Continue Continue Untitled Scene Troubleshooting the Atellica® Sample Handler Connect Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Welcome This video will explain various tasks that need to be performed with troubleshooting the Atellica Sample Handler Connect. Troubleshooting the Sample Handler Connect (SHC) Tasks involved in troubleshooting the SHC: Unlock and open the SHC cover Remove the SHC Atellica Magline Transport cover Remove a tube from the grippers Remove debris and clean spills Inspect gripper tips and replace if needed Clear carrier jams Install SHC Atellica Magline Transport cover and resume Atellica Magline Transport Close and lock SHC cover, and resume SHC Introduction Atellica Sample Handler Connect errors can be caused by several hardware issues, including tubes stuck in the grippers, obstructions and spills, and carrier jams. There are several tasks that the operator can perform to troubleshooting these issues. This video will show you how to perform these common troubleshooting tasks. Use the table of contents at the left or the Next buttons at the bottom to skip to the task that you would like to view. Unlock and Open the SHC Cover Unlock and Open SHC Cover Remove the SHC Atellica Magline Transport Cover Remove SHC Atellica Magline Transport Cover Remove Tube from SHC Grippers Remove Tube from Grippers Remove Debris and Clean Spills Remove Debris and Clean Spills Inspect the area around the Sample Handler Connect and the Atellica Magline Transport to check for spills or dropped sample containers. As appropriate, follow the steps to open the Sample Handler Connect cover and/or remove the Atellica Magline Transport cover to access the spill. If there are any dropped sample containers, remove them from the system. Clean the area if appropriate by first wiping the area with lint-free tissues or gauze saturated with a 10% bleach solution. Then wipe the area with lint-free tissues or gauze saturated with reagent water. And dry the area thoroughly with clean lint-free tissues or gauze. After completing any additional troubleshooting steps as appropriate, follow the steps to close the Sample Handler cover and/or reinstall the Atellica Magline Transport cover. Inspect SHC Gripper Tips and Replace If Needed Inspect Gripper Pads and Replace if Needed Clear Carrier Jams Clear Carrier Jams Install SHC Atellica Magline Transport Cover and Resume Install SHC Atellica Magline Transport Cover and Resume Close and Lock the SHC Cover, and Resume SHC Close and Lock SHC Cover, and Resume SHC You have now completed Troubleshooting the Atellica® Sample Handler Connect. Thank You! Completion Siemens Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer HOOD05162003145803_Effective Date 7-DEC-2020 1.1 Welcome 1.2 Introduction 1.3 Unlock and Open SHC Cover 1.4 Remove SHC Atellica Magline Transport Cover 1.5 Remove Tube from Grippers 1.6 Remove Debris and Clean Spills 1.7 Inspect Gripper Tips and Replace if Needed 1.8 Clear Carrier Jams 1.9 Install SHC Atellica Magline Transport Cover and Resume 1.10 Close and Lock SHC Cover, and Resume SHC 1.11 Completion 1.12 Siemens Healthineers 1.13 Disclaimer
- atelica
- atellica
- attellica