US Freestyle Tips and Alerts to Prevent Probe Loss
This is a PDF that describes the multiple features for prevention of probe loss on the ACUSON Freestyle Ultrasound system.
ACUSON Freestyle Series Tips and alerts to prevent probe loss Learn how to track and protect your investment with ACUSON Freestyle Series Ultrasound Systems Probe Localization for cable-free probe security. Remember best practices to keep your probes safe and secure from damage and loss. Setup* Alerts Set Probe Localization alerts under Setup/System/Probes. Probe Localization reminder Audible reminder tones message is displayed on are produced by probe Study List System conditions described under and system on conditions System Setup. described under Setup. Network Display Setup Probes Locate Probe ) Please locate and secure L8-3 probe OK Low/Medium setting Probe Localization message and/or tone notification produced when study is closed, probe turned off, or the console is turned off. Best Practices -Probes- Enable Probe Keys Lock .......................... .............. 5 sec. When exam is complete, place probe with other non- M Enable Probe Middle Keys ...... ........ Save disposable instruments, or hand off probe to an assistant Enable Probe Localization Alerts. ..... Medium to store in a secure location. Enable Automatic Freeze Low + Restrict wireless operation to checked probes Medium Name Serial Number Medium + High L8-3 100208 High + 0,0 High setting Visual and/or tone notification produced when probe is inactive, study is closed, probe turned off, or the console is turned off. Warning: Do Not leave Automatic freeze is automatically enabled. probe on patient during procedure (increases the Locate Probe chance of probe loss and Please locate and secure L8-3 damage by falling onto probe floor). OK Remove sheath and clean probe and battery separately with approved disinfectant and immediately return probe to secure location. ANL 0.0 de Auto-Freeze timeout Measure *For more information on system Setup, please refer to the Operators' Manual. SIEMENS Healthineers . siemens-healthineers.com/freestyle ACUSON Freestyle is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 685 East Middlefield Road Phone: +49 9131 84-0 Mountain View, CA 94043, USA siemens-healthineers.com Phone: +1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · Order No. A91US-591-1C-4A01 Printed in Germany · CIT13112 6603 1018· © Siemens Medical Solutions USA, Inc., 2018
- US Freestyle Tips and Alerts to Prevent Probe Loss
- freestyle