Using syngo.via WebViewer: Mobile Devices Job Aid
This job aid explains how to access syngo.via WebViewer on a mobile device using the iOS application, how to search for patients and studies, which visualizing features are available and how to start a virtual conference to share your images.
Using syngo.via WebViewer – Mobile Devices Job Aid syngo.via WebViewer The syngo.via WebViewer 1 is the mobile extension of your syngo.via, enabling mobile reading of images with diagnostic-quality graphics and collaboration within the hospital network or on the go 2 . The syngo.via WebViewer is an iOS application supporting iPad, iPhone and iPod as well as your favorite browser 3 . The syngo.via WebViewer is indicated for reviewing medical images from syngo.via to support interpretation in the field of radiology, nuclear medicine and cardiology. This device should be used only when there is no access to a workstation. syngo.via WebViewer 12. Siemens Healthineers Free SIEMENS Healthineers Screenshots iPhone iPad 1 The application syngo.via WebViewer is not for diagnostic viewing/reading on mobile devices in the US. Please refer to your sales representative whether the product is available for your country. Diagnostic reading of images with a web browser requires a medical grade monitor. For iPhone and iPad, country specific laws may apply. Please refer to these laws before using for diagnostic reading/viewing. For Japan: Applications on iPhone / iPad / iPod are not a medical device in Japan. Use at your own risk. They are not intended to be used for diagnosis. 2 Prerequisites include: wireless connection to clinical network, meeting recommended minimum hardware requirements, and adherence to local data security regulations. 3 Apple®, iPhone®, iPad®, iPod Touch® are trademarks of Apple Inc., registered in the U.S. and other countries. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 1. Login After downloading the app on your device, syngo.via WebViewer allows you to configure your own server or use the Siemens Healthineers Demo server. The application enables to login with TouchID and FaceID 4 . 5:42 Seg 16 de nov 100% 15:43 Seg 16 de nov 100% SIEMENS. Salvar Add Server Cancelar Healthineers Server Name Short Name syngo.via Address Host Name or IP Address v2020.1.11.0 WebViewer SSL Port Leave empty for 4475 Comment Any Text Ke User Name Name Password Password Server No Servers This app requires a server to operate. You do not have any servers configured. Would you like the app to automatically find a demonstration server? Or you can manually add a server. Manual Demo Quick Guide For safe use of this device, please refer to the online help. Imprint Quick Guide Terms of Use Copyright @ 2012-2020 HipGraphics, Inc. 4 In productive system in hospital, user of syngo.via WebViewer app must be listed in syngo.via user management (AdminPage). syngo.via WebViewer has no separate user management. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 2. Patient After you have logged on with a new session, the Search Studies screen is displayed and the system will show a pop-up window with Hints & Tips. On the Search Studies screen, enter the name, ID, or the date of birth of the required patient or refine the search. If you want to search for studies of a specific modality, you can select the required modality from the list. 14:31 Ter 17 de nov 82% Q Study List 14:32 Ter 17 de nov 82% 17/11/2020 14:31 Cancelar Search Studies X 4D Mitral Valve CT 1300 O Annonymous 2020-08-01 AAA Stent CTA CT Search Search for studies matching the criteria. 1300 O Annonymous 2020-08-01 Aortic Dissection Cinematic CT,SR 2020-01-01 00:00:00 O KEINEID 2020-01-01 Name Patient Name Bi Phase Liver CAP Cinematic CT 1300 O Annonymous 2020-07-01 ID Patient ID Carotid COW CTA Cinematic CT 1300 O Annonymous 2020-07-01 Birthdate YYYY-MM-DD Carotid Gliomic Tumor CT 1300 O Annonymous 2020-08-01 Study Date All Dates › ChestAbdPelvis CT 1300 O Annonymous 2020-08-01 Modalities ChestAbdPelvis CT 0100 O Annonymoy Hints & Tips Coronary 101b The tips and hints functionality has settings that can be controlled using Clear CT Clears all the search criteria. 0100 0 Annonymou the Settings entry on the More menu. You can turn off the hints and tips COVID-19_AIR entirely, or reset the hidden tips settings. CT 2020-03-01 1200 COVID-19_gou CT,SEG, SR 2020-04-01 1200 F COVID-19_gol Don't show this tip again CT 2020-04-01 1200 F < X COVID-19_gou 2020-04-01 1200 F Previous Next Close CT,SR,SEG CTA Renal Donor Cinematic CT 0100 O Annonymous 2020-07-01 Luminos Agile Max, Abdomen, Radiography CR 2015-01-01 0000 M PID110 2015-01-01 Mobilett Mira Max, Chest, Radiography CR 2019-01-01 0000 O PID994 2019-01-01 Multitom Rax, Chest, Radiography CR,SC,SR 2020-01-01 0000 M PID576 1981-01-01 Multitom Rax, L-Spine, Radiography CR,SC,SR 2020-01-01 0000 M PID609 1975-01-01 Multix Impact, Ankle, Radiography DX 2020-01-01 0000 M PID420 2015-01-01 PE 45ml Contrast CT 1300 0 Anonymous Ped CCTA CT 1300 O Annonymous 2020-08-01 Ped COW AVM Cinematic CT The following datasets are supported: • X-Ray • AX/XA • CT • MR • PET • PET-CT Fusion • Secondary Capture Images • Encapsulated PDF SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 3. Visualizing syngo.via WebViewer provides access to image data with basic manipulation and measurement functions 5 as well as 3D postprocessing tools. Additionally, a comprehensive toolset, presets, layouts, and views are available. In addition, you can play 4D movies for appropriate data sets. 15:23 Ter 17 de nov 71% Window Distance ROI Lens Delete No Text 4D Cut Plane Slab Distan ROI Delete VRT No Text MIP 4D It Plane Slab VRT MIP MPR 2D MPR Thin MPR Modes Orientation Presets Layouts View 5 Tools are provided for temporary image manipulation only and cannot be saved. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 15:29 Ter 17 de nov 69% Window Angio Bone Brain Liver Mediastinum Bunt Soft-Tissue Standard Lung Mediastinum Configure ... Soft-Tissue Standard Configure ... O MIP Modes Orientation Presets Layouts View More Presets 19:41 Qui 3 de dez 44% MPR+3D Dual MPR Single A Coronal L Dual Sagittal IPR A F Coronal L F Sagittal Axial MPR Thin IF Axial MONS Orientation Presets View More Layouts SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 15:23 Ter 17 de nov 2 71% Window Window Tilt Plane Shift Plane Zoom Window Pan Tilt Plane Shift Plane Rotate Zoom E Multi MPR Thin O MIP Mutti H Modes Orientation Presets Layouts View Modos SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 4. Conference 6 The syngo.via WebViewer is your tool to reduce unnecessary contacts with referring physicians, colleagues on call, or clinicians working from home while providing treatment. Easily discuss and share images on-screen. Start a virtual conference from anywhere on the syngo.via WebViewer, and simply invite anyone for a shared case-review, a tumor board, or a seamless collaboration with fellow physicians 7 . All usual imaging functionalities are available to you including our new Shared Visible Pointer 5 . Also included are a do-not-disturb feature for uninterrupted conversations and a simple and secure collaboration with affiliated hospital sites or colleagues on call. 15:23 Ter 17 de nov 71% Window 7:14 Qui 3 de dez 70% Virtual Conferencing WebViewer Virtual Conferencing is a feature that allows you to have collaborative sessions with other WebViewer users. In a collaborative session, everyone sees the same images on their screens, and everyone can interact with the images. You can issue invitations to other users to join you in a session and also accept invitations from other users to join them in a session. To try out this feature have one or more of your colleagues login to the same demo server and then issue an invitation to their demo usernames. Your demo username is user19. Continue Quality Close MPR Thin O MIP Conference Conference Modes Orientation Presets Layout Orientatio 5 Tools are provided for temporary image-manipulation only and cannot be saved. 6 Including on VA20 Version. Anyone participating in a conference needs to be registered as a syngo.via user. It is at our customers’ discretion whom they would like to give access to the syngo.via WebViewer and syngo.via. 7 The performance of the syngo.via WebViewer client depends on your network connection speed, the network latency between your location and the server as well as on the number of active users. In locations farther from for example the server, the performance can be slow. If you encounter a pop-up message stating “Currently no user license session available”, please wait a few minutes and try again. We recommend a wireless internet connection with a minimal speed of 3.5 Mbits. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-21 I HOOD05162003167893 7:15 Qui 3 de dez 70% 17:16 Qui 3 de dez 70%[ Virtual Conferencing X < Virtual Conferencing Invite X Virtual Conferencing is a feature that allows you to have collaborative sessions with other WebViewer users. In a You can use this page to create an invitation for a collaborative session. Fill in the information below and touch the collaborative session, everyone sees the same images on their screens, and everyone can interact with the Send Invitation button. Note that the demonstration mode app does not let you change the subject or duration. images. You can issue invitations to other users to join you in a session and also accept invitations from other users to join them in a session. To Name or username Show Invitations Show invitations vou have received and sont Subject Virtual Conferencing Demonstration at 17:16 Create Invitation Send an invitation to other users to join you. Duration 1 hour Show WebViewer Users Show the list of users currently using the system. Send Invitation Contact Information Touch this button to issue the invitation with the above details. Show and edit your contact information. Conference Information You are not currently part of a conference. Normally you will be notified when a user invites you to a joint session and you are logged in. If you do not want to be notified, you can turn on 'Do Not Disturb' mode to avoid being interrupted. You can still accept invitations, but you will have to view the invitation and accept it. Do not disturb mode is turned off every time you login. Do Not Disturb SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 22-Feb-21 I HOOD05162003167893 Job Aid I Using syngo.via WebViewer – Mobile Devices Effective Date: 22-Feb-2021 I HOOD05162003167893 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers
- snygo
- webviewer
- web-viewer
- web viewer
- ios
- apple