VB22 MI Applications Online Training - USA
This online training is intended to train you on new features and functionalities of the VB22 software for SPECT/CT systems and MI Applications.
Congratulations. You have completed the VB22 MI Applications online training. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. VB22 - Enhancements Operating system update: syngo MI Apps VB22 has been updated from Windows 7 to Windows 10. With the end of Microsoft´s support for Windows 7 you are susceptible to cybersecurity issues, risking harm to health care information. With syngo MI Apps VB22, being released on the Windows 10 operating system, you can ensure that there less vulnerability to security risks and viruses. I131 in the xSPECT Quant portfolio: This feature allows you to easily standardize uptake values of I131 across different centers, cameras and dose calibrators to evaluate an absolute response to follow up. Application enhancements: Gastric Processing: Gastric retention results includes percent retention for better alignment with Society of Nuclear and Medicine Imaging (SNMMI) guidelines. Renal Processing: T-fit Curve: The T-fit Curve in the renal activity has been updated to extrapolate the renal T 1/2 past the end point of the acquisition. If the value is extrapolated, it is noted with an asterisk. ROI tool button: The magnify tool has been added to the tools to allow you to zoom the image. This will help with drawing the ROIs for the left and right kidney as well as the background ROIs. MI Apps Patient Browser: The MI Apps Patient Browser will automatically refresh upon completion of a workflow. Recycling Bin: If data is ever deleted by accident, the MI Patient Browser features a new Recycling Bin, which holds the deleted data. To avoid deletion of patient data by accident during dynamic studies, additional notifications have been added to the Dynamic Acquisition activity in VB22. If you changed parameters in the Static Acquisition activity, but forgot to click the Update View button before clicking on Prepare Acquisition, a new popup window will appear stating Acquisition parameters have been changed. This allows you save the parameter changes by clicking OK and then continuing with the acquisition. Incorrect collimator pop-up: Collimator field has been added to Camera Parameters tab within the acquisition activities.This collimator field can be configured and saved in the workflow. If the collimator is incorrect, Upon prepare, a pop-up will notify the user. Control Room Scan Beep: In addition to the beep coming from the scanner to signal the end of a acquisition, a beep will also occur at the console. This is configurable (on/off) within Options > Local Service > Configuration > ScanEndBeep. syngo MI Application features SPECT Dose Report: SPECT Dose Reports are created for all acquisitions each time radiopharmaceutical information is entered in an activity. The dose report contains the following information: radioisotope radionuclide half-life injected dose injected date and time patient weight patient height effective dose adsorbed dose to organs CT features available for SPECT/CT systems FAST Planning: This feature helps you to plan the scan and reconstruction for an easier, faster, and more standardized workflow. FAST Spine: FAST Spine facilitates accurate and anatomically aligned preparation of spine recons with just a single click.This feature is available for Symbia T6, T16, Intevo 6, 16, and Intevo Bold systems. Upon successful completion of this course, you will be able to: Identify the VB22 application enhancements Identify the syngo MI Application features Create a SPECT Dose Report Use the CT features available for SPECT/CT systems: FAST Planning and FAST Spine Welcome to the VB22 MI Applications online training. In this training you will learn about the new features and enhancements that are available with the VB22 software version for SPECT/CT and SPECT systems. Please note: The new enhancements are structured according to different areas of interest. You can navigate directly to the required modality in the table of contents area. This chapter introduces you to the enhancements of the VB22 software version. VB22 is the first software version to be released on the Windows 10 operating system. VB22 software release also includes new versions of: syngo – VI20C Somaris 5 3rd party software: Corridor 4DM – 2018 Cedars – 2017 Scenium – VE30A TrueD – VB20 To learn more about the software and application enhancements with VB22, click the tab below. Learn more about the VB22 Application enhancements Learn more about the VB22 MI Application enhancements Tab TitleTextGastric Processing Renal Processing MIApps Enhancements: Workflow Enhancements With VB22 there are two additional FAST (Fully Assisted Scanner Technologies) features available as options for use with diagnostic CT scans: FAST Planning: This feature helps you to plan the scan and reconstruction for an easier, faster, and more standardized workflow. FAST Spine: This feature facilitates accurate and anatomically aligned preparation of spine recons with just a single click. It is available on the Symbia T2, T6, T16, Intevo 2, 6, 16, and Intevo Bold systems. To learn more about the new CT features, click the tab below. Learn more about the new CT features Learn more about the new CT features Tab TitleTextFAST Planning FAST Spine Select the link to download or print the FAST Spine Job Aid This chapter introduces you to the new features of the syngo MI Applications (MI Apps) software. syngo MI Apps is the Siemens SPECT and SPECT/CT software that allows you to acquire, process, display, print, and archive images. There are three layers to the syngo MI Apps software platform: Windows operating system syngo: a multi-modality software platform MI Applications: specific to the use of the SPECT and SPECT/CT system for acquiring and processing patient data To learn more about the enhancements and the new features for syngo MI Applications, click the tabs below. Learn more about the syngo MI Apps VB22 software f Learn more about the syngo MI Apps VB22 software features Slide NumberText BlocksCalloutsAudio ScriptImage File1Windows 10 With version VB22 of syngo MI Applications (MI Apps), the operating system has been updated from Windows 7 to Windows 10. With the end of Microsoft´s support for Windows 7 you are susceptible to cybersecurity issues, risking harm to healthcare information. With syngo MI Apps VB22, being released on the Windows 10 operating system, you can ensure that there is less vulnerability to security risks and viruses. With version VB22 of syngo MI Applications (MI Apps) the operating system has been updated from Windows 7 to Windows 10. With the end of Microsoft´s support for Windows 7 you are susceptible to cybersecurity issues, risking harm to health care information. With syngo MI Apps VB22, being released on the Windows 10 operating system, you can ensure that there is less vulnerability to security risks and viruses. 2xSPECT Quant I131 With syngo MI Apps VB22, I131 is now available in the xSPECT Quant portfolio. This allows you to easily standardize uptake values for I131 across different centers, cameras and dose calibrators to evaluate an absolute response to follow up. xSPECT Quant I131 is the same as for the other isotopes: Technetium99m Iodine123 Indium111 Lutetium177 The only difference for calibrations is a Sn113 precision source when a High Energy collimator is used. With syngo MI Apps VB22, iodine131 is now available in the xSPECT Quant portfolio. This allows you to easily standardize uptake values for I131 across different centers, cameras and dose calibrators to evaluate an absolute response to follow up. The acquisition and processing for xSPECT Quant I131 is the same as for the other isotopes: Technecium99m, Iodine123, Indium111, and Lutetium177 except that the supported collimator is High Energy. The only difference for calibrations is a Sn113 precision source when a High Energy collimator is used. Learn more about the Dose Report Updates Learn more about the Dose Report Updates Select the link to download or print the SPECT Dose Report Job Aid. After reading the disclaimer, please proceed to the final assessment to complete the online training. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH, 2019
- VB22
- enhancements
- MI Apps
- syngo
- MI
- Apps
- Spect/CT
- features
- FAST
- Planning
- FAST
- Spine
- Gastric
- renal