VersaCell™ System Connected to IMMULITE® Systems Online Training
This will familiarize the operator with aspects of operation that are unique when the VersaCell™ system is connected to an IMMULITE® Immunoassay System.
Describe the journey that sample tubes, test orders, and results take when traveling among the VersaCell™, the LIS, and the IMMULITE® systems Describe the start up and running controls features that are unique to the connection of a VersaCell™ to the IMMULITE® systems Identify the steps to correct errors unique to the connection of a VersaCell™ to the IMMULITE® systems Recognize the IMMULITE® screens that would be useful to a VersaCell™ operator The goal of this course is to familiarize the operator with aspects of operation that are unique when the VersaCell™ is connected to the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems. After completing this course, the operator will be able to: Select Next to continue. Bienvenido a la formación online de Control de Calidad del Analizador RAPIDPoint ® 500. La función de control de calidad se utiliza para garantizar la precisión de los resultados en todos los parámetros medidos. Haga clic en Siguiente en la esquina superior derecha de la pantalla para dar inicio al curso. Connection of a VersaCell™ to the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 Systems: Does not use an Interface Wheel Samples from the VersaCell™ are placed directly on the Automation Rack, which is affixed to position 6 of the Sample Carousel Let’s look at the journey that sample tubes, test orders, and results take as they travel among the VersaCell™, the LIS, and the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems. Tube Journey Watch the VersaCell™ in action. Select the play arrow to begin the video. When complete, select the X in the upper-right corner to close the window and continue. En esta sección, usted aprenderá cómo consultar los resultados de control de calidad. Start-up features unique to the connection of a VersaCell™ to the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems: On the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 screen, a “Received Reinitialize 1” message indicates that communication has been established with the VersaCell™ On the VersaCell™ screen, the instrument status remains a red “Not Connected” until the connected instrument’s software is initialized and the prompt to delete the worklist is answered Start Up Watch the start-up process in action. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003149/VC_IMM_STARTUP_skin.swfHTML5 File:/content/generator/Course_90003149/VC_IMM_STARTUP2_HTML5_800x573/index.htmlPDF File: Integrated Mode Learn about the Integrated Mode configuration setting. If the VersaCell™ and the connected instrument are not communicating, despite the software on both being initialized, the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 system may not be configured to communicate with the VersaCell™. To verify the configuration, the operator should check the Integrated Mode setting in the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 software. From the IMMULITE® 2000 or IMMULITE® 2500 Configurations menu or from the IMMULITE® 2000 XPi Menu screen: Select Configure. Select Instrument Mode Enter sms when prompted to enter a password In Integrated mode, the VersaCell™ and the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems will communicate. In Non-Integrated mode, the VersaCell™ does not communicate with the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems. In Integrated mode, the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems do not automatically stop 20 minutes after the last sample is processed. When complete, select the X in the upper-right corner to close the window and continue. IMMULITE® 2000 XPi AutoStart Learn more about the start-up process on the IMMULITE® 2000 XPi. The following are differences in the start up process when the VersaCell™ is connected to an IMMULITE® 2000 XPi system and the AutoStart feature is used: When AutoStart initiates and the IMMULITE® 2000 XPi software reboots, the status of the IMMULITE® 2000 XPi on the VersaCell™ will be the red “Not Connected” message After the IMMULITE® 2000 XPi software completes the reboot and the AutoStart Monitor screen appears, the status of the IMMULITE® 2000 XPi on the VersaCell™ changes to the white “Stop” message The “Received Reinitialize 1” message appears on the IMMULITE® 2000 XPi screen when the AutoStart priming completes When complete, select the X in the upper-right corner to close the window and continue. Herzlichen Glückwunsch. Sie haben den Abschnitt RapidPoint Hardware Übersicht im Online Training Kursus absolviert. Nachdem Sie die Inhalte dieser Seite noch einmal verinnerlicht haben, können Sie mit dem Test fortfahren. For the VersaCell™ connected to an IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 system, not connected to a track: Control samples may be placed on either the connected instrument’s Sample Carousel or in a VersaCell™ Drawer Control test orders may be manually entered in the connected instrument’s software or downloaded from the LIS For the VersaCell™ connected to two IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 systems: Control samples may be placed on either the connected instrument’s Sample Carousel or in a VersaCell™ Drawer Control test orders should be manually entered in the connected instrument’s software to ensure control samples are sent to the appropriate instrument. A worklist of control test orders may be created, saved and imported on each instrument Monitoring Control Test Orders: Control test order statuses and results display on the VersaCell™ LIS screen. Select Next to continue. Accessing the Reagent Inventory window is required when you want to make certain that adequate reagents are loaded on the system prior to processing. This window allows you to verify the following information: presence of reagents, test volumes, reagent lot numbers, expiration dates, remaining reagent on-system stability, calibration status, and QC status. To access the Reagent Inventory window, select the Reagent button from the Menu panel and select the Reagent Inventory button. Once open, the reagent inventory window defaults to RTT1 or reagent tray 1. You must select the RTT2 tab to display the inventory window for reagent tray 2. Columns that are backlit either yellow or red in the Reagent Inventory window require your attention. Yellow indicates a warning for an upcoming shortage, while red indicates immediate attention is needed. Note that the Reagent Inventory window stays open and can be minimized in the Task Bar by the operator and dynamically monitors the reagents in RTT1 and RTT2. Select the link below to learn how to navigate the Reagent Inventory window The VersaCell™ operator uses the VNC buttons to access the following types of information: Time to completion for a test order Determination of which kit component has an error Errors that occurred on the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems VNC Learn about the IMMULITE® screens that are useful to the VersaCell™ operator. Slide NumberText BlocksCalloutsAudio ScriptImage File1This slideshow will display the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 screens that are useful to the VersaCell™ operator. Select Next to continue.Note: If audio does not automatically start, select the play arrow in the top left to begin.This slideshow will display the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 screens that are useful to the VersaCell™ operator.2Display / Edit Accessed by selecting the Worklist button and then selecting Display / Edit. The status column on this screen can be used to determine the time to completion for test orders that have been pipetted. Select Next to continue.The Display Edit screen is accessed by selecting the Worklist button and then selecting Display Edit. The status column on this screen can be used to determine the time to completion for test orders that have been pipetted. 3Bead / Reagent / Show Sample Tubes in Racks Screens Accessed by selecting the appropriate icons from the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 Home screen. Can be used to determine which kit component is missing or has an error when a No Inventory error is encountered on the VersaCell™. IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 diluents should always be placed on the Sample Carousel; therefore the Show Sample Tubes in Racks screen is useful for troubleshooting diluent errors. Select Next to continue.The Bead, Reagent, and Show Sample Tubes in Racks screens are accessed by selecting the appropriate icons from the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 Home screen. These screens can be used to determine which kit component is missing or has an error when a No Inventory error is encountered on the VersaCell™. IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 diluents should always be placed on the Sample Carousel; therefore the Show Sample Tubes in Racks screen is useful for troubleshooting diluent errors. 4Day Error Log Accessed by selecting Day Error Log from the IMMULITE® 2000 and IMMULITE® 2500 Tools menu or from the IMMULITE® 2000 XPi Menu screen. Displays all error messages that occurred on the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems within a 24 hour period. Error messages that are generated by the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems will not appear in the VersaCell™ software. Select Next to continue.The Day Error Log is accessed by selecting Day Error Log from the IMMULITE® 2000 and IMMULITE® 2500 Tools menu or from the IMMULITE® 2000 XPi Menu screen. This screen displays all error messages that occurred on the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems within a 24 hour period. Error messages that are generated by the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems will not appear in the VersaCell™ software. 5Automation Rack Screen Accessed by selecting the Automation Rack position (position #6) from the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 Home screen. Provides a way for the operator to determine the status of the samples that are on the Automation Rack. The incubator load box can be checked to view the percentage of Incubator space in use. Select Next to continue.Select each number to review the corresponding text.CalloutsSample in the Gripper Incubator LoadThe Automation Rack screen is accessed by selecting the Automation Rack position from the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 Home screen. This window provides a way for the operator to determine the status of the samples that are on the Automation Rack. The information in the To Sample box describes the sample tube that is in the Gripper waiting to be placed on the Automation Rack. The other three sample boxes contain information about sample tubes that are in the three positions on the Automation Rack. The incubator load box can be checked to view the percentage of Incubator space in use. 6Congratulations. You have just learned about the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 screens that are useful to the VersaCell™ operator: Display / Edit Reagent / Bead / Sample Screens Day Error Log Automation Rack Screen When complete, select the X in the upper-right corner to close this window and continue.Congratulations! You have just learned about the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 screens that are useful to the VersaCell™ operator. Der Analyse-Bildschirm ist der Standardbildschirm des RapidPoint ® 500 Blutgas Analysators. Alle Proben und deren Optionen werden von diesem Bildschirm aus gestartet. Hier erfolgen auch die Definitionen für Probenart, Parameterwahl, Patientenprofile oder die Auswahl einer manuellen Qualitätskontrolle oder einer manuell initiierten AQC. The most frequently encountered operator errors that are unique to the connection of the VersaCell™ to the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems are inventory errors. Inventory Errors include: Missing bead packs, reagent wedges, or diluent needed to run a particular test Problems with onboard bead packs, reagent wedges, or diluent (for example, an improperly placed reagent wedge or bead pack) Inventory Errors Learn how to configure Inventory Alarms on the VersaCell™. The VersaCell™ can be configured to alert the operator when the connected instrument is running low on beads, reagents, or allergens. Once a Bead Pack, Reagent Wedge, or Allergen level is lower than the alarm limit, an Inventory Error posts on the VersaCell™. To access this setting, from the VersaCell™ Configurations menu bar, select System Configurations and then select Display Options. When complete, select the X in the upper-right corner to close the window and continue. Clearing Tubes from the Automation Rack Learn how to clear tubes from the Automation Rack. If you encounter an error message that states “Clear Tubes from the Automation Rack” on the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 screen, the instrument will automatically put itself into a Sample Pause state. Follow these steps to correct the problem: Select the Pause button on the connected instrument’s Home screen to put the instrument into All Pause. This ensures the Robotic Arm does not travel to the connected instrument while the problem is being corrected. Select Cover in the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 software to unlock the cover. Open the cover and remove any sample tubes from the Automation Rack. Close the cover and select the Run button. When complete, select the X in the upper-right corner to close the window and continue. Inventory Errors Learn how to troubleshoot Inventory Errors. Checklist TitleChecklist TypeChecklist ContentRecognize indications of an Inventory ErrorHTMLSelect each checkbox to learn more about troubleshooting Inventory Errors. There are several ways to identify an Inventory Error using the VersaCell™ screens: The tube will appear as a dark blue color on the Drawer screen The Inventory Errors button at the bottom of the screen will be red The Sample Errors button at the bottom of the screen will be red. Within the Sample Errors screen, an Inventory Error will be listed Select the Inventory Errors button.HTML On the Inventory Errors screen, categories of inventory are listed, such as reagents, diluents, etc. A category name turns red and displays indented test names for specific tests with inventory issues.Correct Inventory Error on connected instrumentsHTML The specific problem can be determined by using the information in the Inventory Errors screen combined with information on the Bead/Reagent/Show Sample Tubes in Rack screens on the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 system. The column names on the Inventory Errors screen can help in the determination of the problem: If the test is listed under the Missing column, either one of the inventory components is not onboard, or the IMMULITE® 2000, IMMULITE® 2000 XPi, or IMMULITE® 2500 system is not connected to the VersaCell™. If a test is listed under the IMMULITE® column, then either one of the inventory components has an error (for example, an improperly placed reagent wedge or bead pack), or the connected instrument is not in Run mode. Automatic sample processing after error correctionHTML Once the Inventory Error is corrected, the VersaCell™ automatically resends the sample tube to the connected instrument for processing. On the Drawer screen, the tube status will change from No Inventory to Waiting, and then to In Progress and Transfer Complete. When complete, select the X in the upper-right corner to close the window and continue. Die Benutzeroberfläche enthält Symbole und Software Tasten. Symbole und Sensortasten sind Informationsträger; jedoch können Sensortasten auch betätigt werden, um einen Vorgang zu starten. In diesem Abschnitt lernen Sie mehr über die häufigsten Symbole und Softwaretasten des Analysators. Lesen Sie bitte dazu auch die entsprechenden Seiten der Bedienungsanleitung. Congratulations. You have completed the VersaCell™ Connected to IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 course.In this online training course, you learned to: Describe the journey that sample tubes, test orders, and results take when traveling among the VersaCell™, the LIS, and the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems. Describe the start up and running controls features that are unique to the connection of a VersaCell™ to the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems. Recognize the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 screens that would be useful to a VersaCell™ operator. Identify the steps to correct errors unique to the connection of a VersaCell™ to the IMMULITE® 2000, IMMULITE® 2000 XPi, and IMMULITE® 2500 systems. Download and print a copy of a PDF that reviews the solutions to common errors that were covered in this course. This can be used as a quick reference guide for troubleshooting.
- inventory errors
- versa
- versacel
- vercacell