Virtual Trainer Offerings for Molecular Imaging 2021 PETCT
This job aid is to describe the Virtual Trainer offerings that may be
included in your education package.
Siemens Education and Workforce Solutions – Virtual Trainer Offerings for Molecular Imaging 2021 PET CT Description: The purpose of this job aid is to describe the Virtual Trainer offerings that may be included in your education package. Virtual Trainers (VT) are sessions of up to 120 minutes. These live, one on one virtual trainings cover general topics determined by your current needs or may be selected from a list of accredited, pre-defined topics. Training may include a remote connection to your Siemens Healthineers imaging console where real-time support and training is provided, or through a web based session using SmartSimulators. An SRS connection must be activated to utilize syngo Remote Assist if being performed at the user console. Registration for this educational offering is performed through Siemens PEPconnect, by selecting the desired session topic, date, and time. Once your registration request is received and verified, a Siemens representative will contact you with further session details and instructions. The Virtual Trainer education offering in your order must be completed by the later of (12) months from purchase or install end date. If training is not completed within the applicable time period, Siemens obligation to provide the training will expire without refund. Virtual Trainer offerings are easily accessed on PEPconnect by following these steps: 1. From the PEPconnect Home Page https://pep.siemens-info.com/en-us, select Explore PEPconnect. SIEMENS Healthineers Explore Search Content and Groups Explore PEPconnect Explore our learning and performance activities available for you! Explore PEPconnect 2. On the following page, select Medical Imaging and Therapy. Medical Imaging and Therapy SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 02/092021 | HOOD/HILS HOOD05162003164311 Job Aid | Siemens Education and Workforce Solutions – Virtual Trainer offerings for Molecular Imaging 2021 Effective Date: 01/27/2021 3. Select Nuclear Medicine Technology – PET from the banner at the top of the Medical Imaging and Therapy screen. Mammography Nuclear Medicine Technology - PET Nuclear Medicine Technology - SPECT Radiation Therapy 4. Click on Nuclear Medicine Technology – PET Content. Nuclear Medicine Technology - PET Content EN 5. Filter the content list by selecting Type of: Virtual Classroom to display all Virtual Trainers. Nuclear Medicine Technology - PET Content Type Of: Virtual Classroom v Language: English v Filter By Title: Enter text Image Production Additional Clinical Education Topics 6. Browse the available Virtual Trainer topics and register for your session by selecting the Register button next to your desired date/time (login required). Monday, 01 February 2021 2:00 p.m. EST February 01, 2021 Register 02:00 PM - 04:00 PM EST WITH Siemens Instructor 1 Seats Available more details Below, you’ll see our current lineup of accredited PETCT related Virtual Trainers 3D Task Card and Fusion Virtual Trainer Session This 2-hour Virtual Trainer session will provide instruction on how to navigate the 3D Task Card and how to use it to view and evaluate images. Topics that will be covered include loading a patient from the Patient Browser, using the Viewing tools and performing image fusion. Additionally, the session will provide instruction in how to create parallel ranges, radial ranges, curved ranges, and stand-alone CT ranges. Effective Date: 4/16/2020 - 1.75 CEU SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 02/092021 | HOOD/HILS HOOD05162003164311 Page 2 of 6 Job Aid | Siemens Education and Workforce Solutions – Virtual Trainer offerings for Molecular Imaging 2021 Effective Date: 01/27/2021 CT Examination Card for Hybrid Imaging Virtual Trainer Session-PETCT This 2 hour Virtual Trainer session is developed for the end user to become familiar with setup, acquisition, and reconstruction of CT images on a PET/CT scanner. Topics for this session will include components of the CT Examination Card and its associated sub task cards (Routine, Scan, Recon, Auto Tasking and Trigger). Scan parameters will include CT kernels, slice thickness, windowing and Field of View (FOV). Scanning procedures include RT scanning with flat tabletop and respiratory gating. Effective Date: 4/17/2020 - 1.75 CEU TrueD Lite Virtual Trainer Session This 2 hour Virtual Trainer session is developed for the end user to become familiar with the use of TrueD Lite and how it’s used. Topics for this session will include the use of the common tools, sub taskcards, creating ranges and MIP images, and basic quantification measurements. Effective Date: 4/20/2020 - 1.75 CEU PETCT Reconstruction Virtual Trainer Session This 2 hour Virtual Trainer session is developed for the end user to become familiar with reconstruction of CT and PET images. Topics for this session will include the various parameters for CT, such as CT kernels, slice thickness, windowing and field of view (FOV). The various PET parameters will also be reviewed, such as the various algorithms, filters, attenuation correction and matrix sizes. Effective Date: 4/20/2020 - 1.75 CEU Advanced Procedure Protocol Building Virtual Trainer Session This 2 hour Virtual Trainer session is developed for the end user to become familiar the process of creating protocols for use in their department. In this session, the instructor will review the basics of protocol building and move on to creating advanced procedure protocols, such as Ga68, Y90, and radiation therapy planning protocols for their own use. Topics for this session will include Patient Model Dialog, Topogram, CT Routine and Scan subtask cards, PET Routine and Scan subtask cards, editing an existing protocol, saving protocols, deleting protocols and applying protection to protocols from deletion. Effective Date: 4/24/2020 - 1.75 CEU syngo.via MM Oncology Virtual Trainer Session This 2 hour Virtual Trainer session is developed for the end user to become familiar with the use of MM Oncology and the interpretation of PETCT images. Topics for this session will include assigning workflow to study, opening and selecting appropriate layout, maneuvering in MM Oncology mouse, review of common tools, corner tools, creating findings, measurements, Aligning multiple timepoints, CT RECIST, PET measurements, lesion trending, MM Reading, Spine and rib labeling. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 02/092021 | HOOD/HILS HOOD05162003164311 Page 3 of 6 Job Aid | Siemens Education and Workforce Solutions – Virtual Trainer offerings for Molecular Imaging 2021 Effective Date: 01/27/2021 Effective Date: 4/17/2020 - 1.75 CEU PET Biograph mCT VG70A Virtual Trainer Session This 1 hour Virtual Trainer session is developed for the end user to become with the changes and features that are available with their new Biograph VG70A software upgrade. This session with cover the following topics: new computer hardware, PET Dose Report, TeamViewer, SMART Mobile Connect, Whole Body Scatter, CT Low Dose Protocols, PET Image Order, Maximum Clearance Mode, OncoFreeze and CardioFreeze. It will also cover some optional features such as QualityGuard and FlowMotion Multiparametric Suite. Effective Date: 1/18/2019 - HOOD05162002980928 1 CEU Biograph Horizon System Overview Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through an overview of the Biograph Horizon PET CT imaging system. Topics covered will include a review of the gantry components, safety features of the system, daily power cycle, patient handling system operation, CT control box, included accessories, and cleaning recommendations. Effective Date: 7/2/2020 - 1.75 CEU Biograph Horizon System Quality Assurance Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through the Biograph Horizon PET CT system’s recommended quality control and calibration procedures. Topics reviewed will include PET daily, weekly, and quarterly quality control; PET QC source positioning; CT quality control; results analysis; and system database maintenance. Effective Date: 7/2/2020 - 1.75 CEU syngo Patient Browser Overview Virtual Trainer Session - PETCT In this one-hour Virtual Trainer session, the instructor will guide the attendee through a review of the syngo Patient Browser, basic trouble shooting, and on-line help. Topics covered will include registering patients, managing databases, and editing and correcting patient data. Effective Date: 7/2/2020 - .75 CEU Biograph mCT and mCT Flow System Overview Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through an overview of the Biograph mCT and mCT Flow PET CT imaging system. Topics covered will include a review of the gantry components, safety features of the system, daily power cycle, patient handling system operation, CT control box, included accessories, and cleaning recommendations. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 02/092021 | HOOD/HILS HOOD05162003164311 Page 4 of 6 Job Aid | Siemens Education and Workforce Solutions – Virtual Trainer offerings for Molecular Imaging 2021 Effective Date: 01/27/2021 Effective Date: 6/25/2020 - 1.75 CEU Biograph mCT and mCT Flow System Quality Assurance Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through the Biograph mCT and mCT Flow PET CT system’s recommended quality control and calibration procedures. Topics reviewed will include PET daily, weekly, and quarterly quality control; PET QC source positioning; CT quality control; results analysis; and system database maintenance. Effective Date: 6/25/2020 - 1.75 CEU Biograph Vision System Overview Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through an overview of the Biograph Vision PET CT imaging system. Topics covered will include a review of the gantry components, safety features of the system, daily power cycle, patient handling system operation, CT control box, included accessories, and cleaning recommendations. Effective Date: 7/3/2020 - 1.75 CEU Biograph Horizon Mobile System Overview Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through an overview of the Biograph Horizon Mobile PET CT imaging system. Topics covered will include a review of the gantry components, safety features of the system, daily power cycle, patient handling system operation, Smart Mobile, CT control box, transport considerations, included accessories, and cleaning recommendations. Effective Date: 7/2/2020 - 1.75 CEU Biograph Horizon Mobile System Quality Assurance Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through the Biograph Horizon Mobile PET CT system’s recommended quality control and calibration procedures. Topics reviewed will include PET daily, weekly, and quarterly quality control; PET QC source positioning; CT quality control; results analysis; special considerations for when the system is transported; and system database maintenance. Effective Date: 7/2/2020 - 1.75 CEU Biograph Vision Quality Assurance Virtual Trainer Session In this two-hour Virtual Trainer session, the instructor will guide the attendee through the Biograph Vision PET CT system’s recommended quality control and calibration procedures. Topics reviewed will include PET daily, weekly, and quarterly quality control; PET QC source positioning; CT quality control; results analysis; and system database maintenance. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 02/092021 | HOOD/HILS HOOD05162003164311 Page 5 of 6 Job Aid | Siemens Education and Workforce Solutions – Virtual Trainer offerings for Molecular Imaging 2021 Effective Date: 01/27/2021 Effective Date: 7/3/2020 - 1.75 CEU PET General Virtual Trainer Live 1-on-1, two hour session that covers a general PET/CT topic of your choice. This offering is not accredited. Effective Date: 3/21/21 - Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and sha ll by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific c ountry is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 02/092021 | HOOD/HILS HOOD05162003164311 Page 6 of 6
- Virtual Trainer Offerings PET