Urinalysis WAM Software using CLINITEK AUWi PRO™ Software Overview Online Training
Validate results. Create workorders during downtime. Identify the location and cause of unregistered results. Resend a sample to the LIS. Resolve barcode read errors in WAM. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the Urinalysis WAM Software Overview Online Training course. This course will introduce you to the location and navigation of the Urinalysis WAM (Work Area Manager) software. This software application manages results from both the CLINITEK Novus™ analyzer and the Sysmex UF-1000i™ analyzer before the results are transmitted to the laboratory information system. Select Next to continue. Describe results management in the CLINITEK AUWi PRO™ system Describe the purpose of Query Order Locate the Urinalysis WAM software Navigate the WAM software Upon successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have Urinalysis WAM Software Overview Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Describe results management The Urinalysis WAM software application is a data management tool that consolidates data from the CLINITEK Novus analyzer and the Sysmex UF-1000i analyzer. Features include: Rules based software to manage results, ability to print a consolidated report, option to validate results before sending the ID to the LIS, and ability to resend a sample ID to the LIS Results are transmitted from the WAM software to the LIS Locate the Urinalysis WAM software Open UA WAM from the Start Menu or Open WAM by selecting the desktop icon Check the Task Bar to confirm there is only one session open Navigate the WAM software Locate screens on title bar drop down menus Use the menu bar with operational buttons Select fast button icons for routine functions Utilize function keys to perform specific operations Describe the purpose of Query Order Search for a sample ID View the sample status Print a consolidated patient report View and/or print a pending list Resend sample ID results to the LIS Select Next to continue. The Urinalysis WAM software application is a data management tool that consolidates data from the CLINITEK Novus analyzer and the Sysmex UF-1000i analyzer. Key features of the WAM software include: Manage sample results in a rules based software Print consolidated reports Validate results before sending sample ID to the LIS Resend sample IDs to the LIS Data Flow Learn about data flow. Slide NumberText BlocksCalloutsAudio ScriptImage File1 CLINITEK Novus to WAM The CLINITEK Novus analyzer runs samples and sends results to the WAM. Results from the CLINITEK Novus analyzer are located in: Main Menu > Recall/Delete Results on the CLINITEK Novus analyzer Urinalysis WAM software Select Next to continue. Note: If audio does not automatically start, select the play arrow in the top left to begin.The CLINITEK Novus runs samples and then sends the results to the urinalysis WAM. Sample results are available in the CLINITEK Novus software and in the Urinalysis WAM. 2Sysmex UF-1000i to WAM When the sample ID is read at the UF-1000i analyzer the options are to query the WAM for a workorder or to run all samples regardless of whether a workorder exits. The Sysmex UF-1000i analyzer results are located in the following software: IPU (Information Processing Unit) Urinalysis WAM Select Next to continue.When the sample ID is read at the UF-1000i analyzer the WAM is queried to locate a workorder. If the workorder does exist the sample is run on the UF-1000i analyzer. If the workorder does not exist the sample will not be run on the system. Results for the UF-1000i are located in the IPU and in the Urinalysis WAM software.3WAM to LIS All results pass through the WAM software to the LIS. Result validation can be performed in either the: WAM software or LIS When complete, select the X in the upper-right corner to close the window and continue. The Urinalysis WAM sends the results to the LIS. The results are validated either in WAM before sending them to the LIS or at the LIS. Your system will be setup for one or the other. The Urinalysis WAM software is an application running on the same computer as the UF-1000i software. Open WAM and then log on to view the functions available the Urinalysis WAM. Navigate the software by using: A title bar with drop down menus A menu bar with operational buttons Fast button icons for routine functions Function keys to perform specific operations Select Next to continue. Query Order is located on the main menu screen in the WAM software. The functions available in Query include: Search for a sample ID View the sample ID status Print a consolidated report View and/or print a pending list Resend a sample ID to the LIS Query Orders Learn about the various functions in Query Order. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Query Order To open Query Order: Select Query Order Identify the search criteria Select Next to continue.Note: If audio does not automatically start, select the play arrow in the top left to begin.Open Query Order from the WAM software main menu screen. Select the criteria for sample ID, patient demographics, test status or just select All Orders and All. 2 Query Order Display Selection criteria Patient data Data Display Print/Resend options Result status color legend Select Next to continue. Select each number to review the corresponding text.Callouts Selection Criteria Patient Data Data Display Print/Resend Options Results Status Color Legend The query order display screen includes a box with the selection criteria chosen on the previous screen. There are multiple columns of patient data including sample id, patient name, demographics and sample status. The columns on the right, display the status of results according to the results status color legend located on the bottom right corner. Below the data display are the buttons used to print or resend results.3 Query Order Patient Data Select the column header to sort results Select check boxes in the Sel All to identify samples to print or resend Identify the status of results on the R-ST column Use the selp bar to view results R-St column Result Status: 0 - a sample was ordered but not run 1 - a sample was run but not validated 4 - the sample is validated and waiting to be transmitted to the LIS 5 - the sample was transmitted to the LIS Select Next to continue. Select each number to review the corresponding text.Callouts Column Header Check boxes R-St column Selp Bar Columns are sorted in ascending or descending order by selecting the column header. The check boxes on the left are selected to identify those samples that are to be printed or resent to the LIS. The status of the results is displayed with a number in the R-st column. Earlier in the course you learned that a zero indicates a sample that was ordered but not run, a one indicates a sample that was run but not validated, a four indicates the sample is validated and waiting to be transmitted to the LIS, and a five indicates that the sample was transmitted to the LIS. Identifying the status of a sample is important when trying to locate sample results that did not cross over to the LIS. The selp bar is used to view sample results.4 Query Order Data Display Select a row of data to view status of results related to that sample Yellow highlighting indicates the row selected Select Next to continue. Image: screen capture of query right columns The data display identifies the status of the sample results by the color coding used. Grey indicates which sample results were validated. A white background indicates the results that are either pending or waiting to be validated.5 Query Order Print/Resend Options Print List of Selection Print Results of Selection Resend Selection to LIS Select Next to continue. Select each number to review the corresponding text.Callouts Print a list of pending samples Print consolidated patient reports Resend sample ID's to the LIS The Urinalysis WAM provides different options for printing and resending orders to the LIS. The print list of selection can be used to print a pending list of samples. Resend a sample to the LIS if the results for a sample need to be retransmitted. The samples to print or send are determined by the checkboxes selected. The resend to instrument is not used.6 Query Order Result Status Color Legend indicates the status of results for a selected sample. When complete, select the X in the upper-right corner to close the window and continue. The legend indicates the color coding used to indicate the status of the results. The h's and L's for high and low results are not commonly used. Access to the WAM software is available by selecting either: Start from the Start Menu and then WAM or The WAM icon on the desktop Access the UA WAM Software Learn about accessing the Urinalysis WAM software. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Accessing the WAM software To open the WAM software: Select Start and then select the WAM icon or Select the WAM icon on the desktop Select Next to continue. Select each number to review the corresponding text.Note: If audio does not automatically start, select the play arrow in the top left to begin.Callouts WAM icon in Start menu WAM icon on Desktop To open WAM select Start from the start menu and then select the WAM icon. It may take a few seconds for the user interface to appear. Another option is to select the WAM icon directly on the desktop. Check the task bar to confirm there is only one WAM session open.2 Accessing the WAM software Log on to WAM using: Username: usr Password: wam When complete, select the X in the upper-right corner to close the window and continue. Log on to WAM by typing in lower case u s r as the username in the small field of the user name and w a m as the password. The software displays the username in capital letters. User names and passwords can be customized in WAM. Software navigation is controlled by the: Mouse Function keys. Software Navigation Learn how to navigate the software. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90008426/sim_WAM_SWOverview_800x600/sim_WAM_SWOverview_800x600.htmHTML5 File:/content/generator/Course_90008426/sim_WAM_SWOverview_HTML5_800x600/index.htmlPDF File:
- clini
- clinical laboratory training