Xprecia Stride™ Coagulation Analyzer System Overview Online Training
Locate key components and determine their functions to successfully operate the analyzer. Navigate through software screens for ease in system usability.
Welcome to the Xprecia Stride™ Coagulation Analyzer System Overview Online Training course. The Xprecia Stride™ Coagulation Analyzer is a handheld: Analyzer that provides quantitative Prothrombin Time (PT)/International Normalized Ratio (INR) results System that only requires a small amount of blood Device for healthcare professionals in point-of-care settings Select Next to continue. Describe the major hardware component functions Identify major hardware components List the accessories and consumables Navigate the analyzer user interface Upon successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have completed the Xprecia Stride™ Coagulation Analyzer System Overview Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Identify major hardware components Touch screen On/Off button Strip port Eject button Barcode reader USB cable port Describe the major hardware component function Touch screen used to navigate the analyzer interface Eject button discards the test strips safely On/Off button turns the system on and off Barcode reader scans test strip and LQC information, operator ID, and patient ID Strip port test strips are inserted and tests performed USB cable port connects analyzer to the DMS to transfer results Navigate the user interface Home screen software screen that appears upon start up Recall results used to view results, warnings, and error messages Patient test used to perform a patient test Settings used to customize system settings, tutorials to perform tests, and hold analyzer QC test used to perform a liquid QC (LQC) test List the accessories and consumables Accessories: Consumables: Test strip port protective caps USB cable Data Management Software (DMS) Test strips Select Next to continue. The Xprecia Stride™ Coagulation Analyzer Hardware Components include: Touch screen On/Off button Strip port and protective cap Eject button Barcode reader USB cable port The Xprecia Stride™ Analyzer Hardware Components Select this link to learn more about the Xprecia Stride™ Coagulation Analyzer hardware components. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Touch screen Used to navigate the system software Use your finger to tap the screen Alphanumeric characters to perform tasks Enter Operator ID (key pad or the barcode reader) Select Next to continue. Slide QuestionAnswer Text How do I operate this slideshow? At the top of the slideshow, you will find several buttons to operate the slideshow: To advance to the next slide, select the Next arrow, or select an area on the screen or image, if instructed. Select a numbered slide or use the Previous and Next arrows to navigate at your own pace. Audio plays automatically. Select an audio level to adjust the volume. Select Pause to stop and Play to resume the slideshow. Tip: Select and drag the border of the Q & A box if it is in your way. You can also minimize or maximize the box. Callouts Touch screen The touch screen on the analyzer is used to navigate the Xprecia Stride™ Coagulation Analyzer. Use your finger to tap the touch screen to navigate through the user interface and perform routine tasks. An operator ID can be entered using the barcode reader or on-screen key pad. Select Next to continue. 2 On/Off button Turns the system On Turns the system Off Select Next to continue. Callouts On/Off button The On/Off button is located on the front of the analyzer just below the touch screen. The On/Off button is used to turn the Xprecia Stride™ Coagulation Analyzer power on and off. Select Next to continue. 3 Test strip port Test strips are inserted Test strips are heated Analyzes and calculates results Select Next to continue. Callouts Test strip target area The test strip port is located at the top-right of the Xprecia Stride™ Coagulation Analyzer. The test strip port is where the test strips are inserted to perform a test. Test strips are intended for single use testing only. Select Next to continue. 4 Eject button Discards the test strips Protects the operator Select Next to continue.Callouts Eject button The eject button is located at the top-left of the Xprecia Stride™ Coagulation Analyzer. After testing has completed, the eject button is used to eject and discard the test strips safely into a biohazard container. The eject button helps users avoid touching biohazardous material. Select Next to continue. 5 Barcode reader Scan test strip information Scan test strip vial information Scan liquid QC (LQC) information Enter Operator ID Enter Patient ID Select Next to continue. Callouts Barcode reader The barcode reader is located at the bottom of the Xprecia Stride™ Coagulation Analyzer. The barcode reader enables you to scan important information about the test strip and test strip vials. This information includes calibration, liquid quality control ranges, lot numbers, and expiration dates. You can also use the barcode reader to enter an operator ID and patient ID number. Select Next to continue. 6USB cable port Connects analyzer to the Xprecia™ Data Management Software (DMS) Allows for bilateral communication to an external PC Exports patient results Exports QC results When complete, select the X in the upper-right corner to close the window and continue. Callouts USB cable port The USB cable port is located on the bottom-right of the Xprecia Stride™ Coagulation Analyzer. The USB cable port is used to connect the analyzer to the Xprecia Data Management Software or DMS, to export results and allows a supervisor to control all analyzers with a common configuration. When complete, select the X in the upper-right corner to close the window and continue. Les artefacts sont des structures de l’image qui ne correspondent pas à la répartition spatiale des tissus à l’endroit de l’acquisition. Il est important de savoir les détecter et les corriger afin d’éviter les erreurs d’interprétation diagnostique. Le cours sur les artefacts de l’IRM explique les différents types d’artefacts, leurs causes fréquentes et la manière dont chacun peut être détecté et réduit afin de produire les meilleures images possibles. The Xprecia Stride™ Analyzer User Interface includes: Touch screen navigation Intuitive functional icons Perform an LQC test Perform a patient test Recall results Settings menu Xprecia Stride™ Analyzer Software Overview Select this link to learn more about the Xprecia Stride™ analyzer interface and functions. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Home screen The software screen that appears upon start up. Icons are displayed to select and perform tasks. Key areas of the Home screen: Battery power Time and date Patient test - perform a patient test Settings - customize system settings Current screen Recall results - view results, warning, and error messages Quality control test - perform a QC test Select Next to continue. Slide QuestionAnswer Text How do I operate this slideshow? At the top of the slideshow, you will find several buttons to operate the slideshow: To advance to the next slide, select the Next arrow, or select an area on the screen or image, if instructed. Select a numbered slide or use the Previous and Next arrows to navigate at your own pace. Audio plays automatically. Select an audio level to adjust the volume. Select Pause to stop and Play to resume the slideshow. Tip: Select and drag the border of the Q & A box if it is in your way. You can also minimize or maximize the box. Callouts Battery power Time and date Patient test Settings Current screen Recall results Quality Control TestThe Xprecia Stride™ Coagulation Analyzer software is intuitive and easy to use. The home screen allows you to tap an icon on the touch screen to perform tests, review results, and to configure your analyzer. Select Next to continue. 2Patient test screen Used to perform a patient test. The user interface will guide you through the steps to perform a patient test. Key areas of the Patient test screen: Scan - barcode reader scans test strip information Home - displays the home screen Help - displays information for a task or current screen Select Next to continue. Callouts Scan button Home button Help button The patient test screen is used to perform a patient test. The Xprecia Stride™ Coagulation Analyzer software will guide you through the process to perform a patient test. The scan button allows you to easily scan the test strip information and patient identification. After you perform a patient test, the results will automatically display. Select Next to continue. 3 Recall results screen Used to recall and view warning messages, error messages, patient test results, and quality control test results. Key areas of the Recall results screen: Patient test results - view patient test results QC test results - view QC test results Events log - view error and warning messages Home - displays the home screen Select Next to continue. Callouts Patient test results QC test results Events log Home The recall results screen is used to recall and view test results, warning, and error messages. The Xprecia Stride™ Coagulation Analyzer software allows you to easily view patient results, QC results, and events by tapping the categories on the recall results screen. Select Next to continue. 4Quality Control test screen Used to perform a liquid quality control test. The user interface will guide you through the steps to perform a liquid quality control test. Key areas of the Liquid Quality Control test screen: Scan - barcode reader scans test strip information Home - displays the home screen Help - displays information for a task or current screen Select Next to continue. Callouts Scan button Home button Help button The liquid quality control test screen is used to perform a liquid quality control test. The Xprecia Stride™ Coagulation Analyzer interface will guide you through the process to perform a quality control test. The scan button allows you to easily scan the test strip information and quality control information. After you perform a quality control test, the result will automatically display. Select Next to continue. 5Settings screen Key areas of the Settings screen: Clock - changes the time Date - changes the date Analyzer - customizes the volume, brightness, battery type, other settings Administrator - enable/disable operator ID (OID), patient ID (PID), and login Page down - displays the next screen Home - displays the home screen Help - displays information for a task or current screen Additional Setting screens*: Language - changes the language settings Information - software version number Tutorial - learn how to perform a patient test, QC test, or hold the analyzer *not displayed When complete, select the X in the upper-right corner to close the window and continue. Callouts Clock Date Analyzer Administrator Page down Home button Help button The settings screen is used to customize the Xprecia™ Stride Coagulation Analyzer. Settings that can be customized range from time and date to administrator settings for operator ID, patient ID and login credentials. The tutorial option under the settings screen teaches the user how to perform a patient test and liquid QC test. When complete, select the X in the upper-right corner to close the window and continue. Navigating and General Action Software Icons Select this link to learn more about navigating and general action icons. Navigating and General Action Icons Back Returns to the previous screen and/or accepts changes you've made Home Displays the Home screen Page Down Displays the next screen in a list Page Up Displays the previous screen in a list Scan Use the barcode reader to scan lot information, an operator ID, or a Patient ID Keypad Use the keypad to enter information Scanner Use the barcode reader to scan information When complete, select the X in the upper-right corner to close and continue. Keypad Screen Interface Icons Select this link to learn more about keypad interface icons. Keypad Screen Icons Alphabetic Keypad Tap to display the alphabetic keypad to enter lower/uppercase letters Extended Keypad Tap to display the extended keypad to enter special characters Numeric Keypad Tap to display the numeric keypad to enter numbers Spacebar Tap to enter a space Delete Tap to delete a character you entered Uppercase Tap to enter uppercase letters Lowercase Tap to enter lowercase letters Accept Tap to accept your entry When complete, select the X in the upper-right corner to close and continue. L’artefact d’ambiguïté du champ magnétique peut survenir quand des signaux de régions situées à l’extérieur du champ de vue apparaissent dans l’image, de manière similaire au repliement. L’artefact peut ressembler à un objet distordu. Les principales causes de l’artefact d’ambiguïté du champ sont la sélection d’éléments d’antenne situés en dehors du volume d’imagerie ou des hétérogénéités locales importantes du champ magnétique, par exemple la présence de matériau ferromagnétique dans le volume d’imagerie. [pause de 10 secondes] Dans cet exemple clinique, l’antenne flexible a été positionne autour du genou du patient. Les éléments du rachis ont été sélectionnés, ce qui crée un signal intempestif qui se replie dans l’image. Afin d’éviter les artefacts d’ambiguïté du champ, on sélectionne uniquement les éléments d’antenne nécessaires pour acquérir une image de la structure anatomique. Cela évite que d’autres parties de l’anatomie se replient dans le volume d’imagerie. The Xprecia Stride™ Coagulation Analyzer Accessories and Consumables include: Accessories Consumables Test strip port protection caps (3 colors) Test strips USB cable Data Management Software (DMS) Xprecia Stride™ Analyzer Accessories & Consumables Select this link to learn more about the Xprecia Stride™ analyzer accessories & consumables. Slide NumberText BlocksCalloutsAudio ScriptImage File1 Test strip port protective caps 3 colors (white cap pre-installed) Protects the strip port Identify multiple analyzers Select Next to continue. Slide QuestionAnswer Text How do I operate this slide show? At the top of the slideshow, you will find several buttons to operate the slideshow: To advance to the next slide, select the Next arrow, or select an area on the screen or image, if instructed. Select a numbered slide or use the Previous and Next arrows to navigate at your own pace. Audio plays automatically. Select an audio level to adjust the volume. Select Pause to stop and Play to resume the slideshow. Tip: Select and drag the border of the Q & A box if it is in your way. You can also minimize or maximize the box. The Xprecia Stride™ Coagulation Analyzer is shipped with test strip port protective caps in 3 colors. A white test strip port protective cap is pre-installed. The test port strip caps protect the strip port and can be used to identify multiple handheld coagulation analyzers. Select Next to continue. 2 USB cable Connects analyzer to Data Management Software (DMS) Exports patient results Exports QC results Select Next to continue. The Xprecia Stride™ Coagulation Analyzer uses the USB cable to connect the analyzer to the Xprecia Data Management Software or DMS. This allows you to transfer patient and QC results to an external system or PC. Select Next to continue. 3 Data Management Software (DMS) Set up and manage operators Configure analyzers Search and export results Select Next to continue. The Xprecia Stride™ Data Management Software provides a simple way to transfer data from the analyzer. The data management software allows you to set up the Xprecia™ Stride Coagulation analyzer and manage operators. Once a number of test results have been collected, they can be uploaded to the DMS to an external system or PC. Select Next to continue. 4 Test strips Single-use only QC integrity check Small amount of blood required Tip: When complete, select the X in the upper-right corner to close the window and continue. The Xprecia Stride™ Coagulation Analyzer utilizes single-use test strips to obtain PT/INR results. When each test strip is inserted, the Xprecia Stride™ Coagulation Analyzer automatically conducts 2 on-strip quality control checks designed to help ensure test strip integrity. After the integrity check, the Xprecia Stride™ test strips require a small amount of blood to perform a PT/INR test. When complete, select the X in the upper-right corner to close the window and continue.
- stryde
- exprecia
- xpresia
- expresia
- LQC
- PT
- INR
- international normalized ratio
- blood
- POC
- point-of-care
- hardware
- software
- Accessories
- consumables
- screen
- strip port
- protective cap
- barcode reader
- USB
- touchscreen
- navigation
- icons
- results
- settings
- dms
- export
- integrity
- hemostasis
- eject