Xprecia Stride™ Coagulation Analyzer Routine Operations Online Training - U.S. version
General overview of Routine Operations for the Xprecia Stride™ Coagulation Analyzer.
Welcome to the Xprecia Stride™ Coagulation Analyzer Routine Operations Online Training course. This course will cover: Performing an LQC test Performing a Patient test Basic maintenance tasks Select Next to continue. Select Next to continue. Describe the steps to perform a QC test Identify maintenance tasks List the steps to perform a Patient test Upon successful completion of this course, you will be able to: Congratulations. You have completed the Xprecia Stride™ Coagulation Analyzer Routine Operations Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Describe the steps to perform a QC test Performing a Quality Control test on the Xprecia Stride™ coagulation analyzer includes: Reconstituting the control solution Applying the control solution Discarding the test strip Scanning test strip information Cleaning the analyzer Viewing the test results Reconstituting the control solution Use transfer pipette to combine the entire volume of 1 vial of reconstitution buffer into 1 control vial. Mix carefully, by swirling the bottle using a circular motion, to completely dissolve all of the control plasma inside. Close the bottle and allow it to sit for at least 5 minutes at 15-25°C (59-77°F). Gently swirl the bottle again prior to use. List the steps to perform a patient test Performing a patient test on the Xprecia Stride™ coagulation analyzer includes: Preparing the patient to collect a blood sample Scanning and inserting the test strip Viewing the test results Cleaning the analyzer Applying the patient sample Entering an Operator ID (OID) and Patient ID (PID) Discarding the test strip Patient collection methods include: Fingerstick sample collection (apply blood to the test strip within 15 seconds of lancing the finger tip) Identify maintenance tasks The Xprecia Stride™ coagulation analyzer maintenance includes: Changing the batteries Changing the test strip port protective cap Cleaning and disinfecting Select Next to continue. Performing a patient test on the Xprecia Stride™ coagulation analyzer includes: Preparing the patient to collect a blood sample Entering an Operator ID (OID) and Patient ID (PID) Scanning and inserting the test strip Applying the patient sample Viewing the test results Discarding the test strip Cleaning the analyzer Patient Collection Method Select this link to learn about the patient collection method. Fingerstick sample collection method To stick the finger, firmly place the lancet against the finger and press the lancet trigger. Gently squeeze from the base of the finger to form a round drop of blood. Apply the drop of blood to the test strip within 60 seconds of sticking the finger tip. Requirement: The drop of blood should be about the same size as the test strip target area (minimum of 6 µL in volume). When complete, select the X in the upper-right corner to close the window and continue. Performing a Patient Test Select this link to learn more about performing a patient test. Instructions:Flash File:/content/generator/Course_90017394/sim_XprS_PerformPatientTest_USversionFinalTest/sim_XprS_PerformPatientTest_USversionFinalTest.swfHTML5 File:/content/generator/Course_90017394/sim_XprS_PerformPatientTest_USversionFinalTest/index.htmlPDF File: Performing a Liquid Quality Control test on the Xprecia Stride™ coagulation analyzer includes: Reconstituting the control solution Scanning test strip information Applying the control solution to the test strip Viewing the test results Discarding the test strip Cleaning the analyzer Reconstituting the Control Solution Select this link to learn about reconstituting the control solution. Slide NumberText BlocksCalloutsAudio ScriptImage File1Xprecia™ System PT Controls Understanding the QC Test: QC tests help meet regulatory compliance requirements, and ensure the analyzer is functioning properly. About Quality Control: The Xprecia™ System prothrombin time (PT) controls kit contains assayed controls for the assessment of precision and analytical bias in the: Normal (Liquid Quality Control PT1) range Therapeutic (Liquid Quality Control PT2) range Select Next to continue. Slide QuestionAnswer Text How do I operate this slideshow? At the top of the slideshow, you will find several buttons to operate the slideshow: To advance to the next slide, select the Next arrow, or select an area on the screen or image, if instructed. Select a numbered slide or use the Previous and Next arrows to navigate at your own pace. Audio plays automatically. Select an audio level to adjust the volume. Select Pause to stop and Play to resume the slideshow. Tip: Select and drag the border of the Q & A box if it is in your way. You can also minimize or maximize the box.Quality control tests help meet regulatory compliance requirements, and ensure the analyzer is functioning properly. The Xprecia System's PT controls kit contains 2 levels of liquid controls for the assessment of precision and analytical bias in the normal and therapeutic range for the Xprecia prothrombin time test strips. Select next to continue. 2 Reconstituting the Control Solution Use one transfer pipette to combine the entire volume of 1 vial of reconstitution buffer (CaCl2) into 1 control vial. Mix carefully, by swirling the vial using a circular motion, to completely dissolve all of the control plasma inside. Do not shake and avoid foam formation. Close the reconstituted mixed vial and allow it to stand for at least 5 minutes at 15-25°C (59-77°F). Gently swirl the bottle again prior to use. Select Next to continue. To reconstitute the control solution, use one transfer pipette to combine the entire volume of 1 vial of reconstitution buffer into the control vial. Mix carefully, by swirling and allow the closed vial to stand for at least 5 minutes at room temperature. Gently swirl the vial again prior to use. Select next to continue. 3 Prior to Performing a QC Test Have the test strip vial and vial lot information on the vial available. Reconstituted control solution vial available. Tip: When complete, select the X in the upper-right corner to close the window and continue. Prior to performing a liquid QC test, have the test strips and liquid control solution vials available. The lot number is printed on the 2D barcode on the side of the respective vial. Now you are ready to perform a QC test on the Xprecia Stride™ coagulation analyzer. Select the X in the upper-right corner when you are finished. Performing an LQC test. Select this link to learn about performing an LQC test. Instructions:Flash File:/content/generator/Course_90017394/sim_XprS_PerformQC_USversionFinalTest/sim_XprS_PerformQC_USversionFinalTest.swfHTML5 File:/content/generator/Course_90017394/sim_XprS_PerformQC_USversionFinalTest/index.htmlPDF File: The Xprecia Stride™ coagulation analyzer maintenance includes: Changing the batteries Changing the test strip port protective cap Cleaning and disinfecting Maintenance Procedures Select this link to learn about the maintenance procedures. Checklist TitleChecklist TypeChecklist ContentChanging the BatteriesHTML Power off the analyzer Press the latch on the battery compartment cover and pull towards you Remove the batteries Replace the batteries Snap the battery compartment cover back into place Note: batteries can be disposable or rechargeable Select each checkbox to learn more about the maintenance procedures. Changing the Protective CapHTML Power off the analyzer Hold the Stride in one hand, grasp the protective cap with the other hand and gently pull it off Align the new protective cap and gently snap into place Cleaning and DisinfectingHTML It is recommended to clean and disinfect the exterior of the stride after every test. Wipe down the exterior with approved cleaning solution (Do not pour cleaning solution in the test strip port) Visibly inspect the test strip port protective cap for debris or dried blood, and if necessary remove it and clean around it Clean the interior and exterior of the cap by rinsing with warm water When complete, select the X in the upper-right corner to close the window and continue.
- stryde
- exprecia
- xpresia
- expresia
- LQC
- patient
- test
- maintenance
- tasks
- control solution
- test strip
- results
- analyzer
- analyser
- cleaning
- reconstitute
- PT
- QC
- quality
- collect
- blood
- finger stick
- batteries
- cap
- disinfect
- hemostasis
- eject