YSIO X.pree Performing Ortho at the Wallstand
This job aid will guide user through how to perform an Ortho Exam at the Wallstand.
YSIO X.pree: Performing Ortho at the Wallstand XPRF Set up 1. In the Scheduler tab, open a patient exam and ensure that the necessary Clinical Protocol Steps are available in the “Assigned Clinical Protocols”. 2. Align the tube with the wallstand at the appropriate SID (180 cm or 300 cm depending on sys- tem set up). If a remote control is available, follow the instructions on the monitor to use the move button to align the tube with the detector, as shown. If no remote control, move the tube into position manually, detent in both directions. Messages (1) Messages (2) -- ........ ............. Press the SmartMove button on wireless Moving towards CP position remote control until the position is reached Press the SmartMove button on wireless remote control until the position is 3. Push the Ortho Stand up again the Bucky Wallstand and then lock it into place. Position the patient on the stand. 4. Measure the distance from the plexiglass to the center of the patient’s vertebrae (the TOD). 5. There are two workflows for setting the range for the images to be taken: the enhanced work- flow using the 3D camera and setting it manually using the overhead tube. These options are displayed on the overhead tube. Clinical protocol step name Ortho W Scolisosis lat i To set image range with camera use the main display. To continue without camera use the tube angulation. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/21/2021 | HOOD05162003187756 Healthineers Job Aid | Performing Ortho at the Wallstand Effective Date: 04/21/2021 | HOOD05162003187756 Enhanced Workflow Using myExam 3D Camera On the monitor in the control room, use your finger to drag the top orange line of the Virtual Col- limation to what will be the top of the stitched image. Drag the bottom line to what will be the bottom of the stitched image. If either line turns red, that area is out of the x-ray range – you must move it back into range. The system can acquire up to 4 images per view. Use the “Show More” button to input the measured TOD. Manual Workflow Using the Overhead Tube Angle the overhead tube up and point the laser light to the area that will define the top of the stitched image. Select the icon on the tube indicating the top of the range. Angle the overhead tube down and point the laser light to the area that will define the bottom range of the stitched image. Select the icon on the tube indicating the bottom of the range. Use the TOD drop down to enter the measured TOD. Acquisition type Wall Stand - TOD (cm) 22 + Define Ortho range TOD (in) Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/21/2021 | HOOD05162003187756 Healthineers Page 2 of 4 Job Aid | Performing Ortho at the Wallstand Effective Date: 04/21/2021 | HOOD05162003187756 Performing the Exam 1. On the right side of the camera view, you will see circles with numbers that indicate the num- ber of images that will be needed. Select each number to see the technical factors being used for each image. NOTE: If you select the different numbered circles to look at each technical factor, you must return to the number 1 circle to begin imaging. ort Ortho W Scolisosis a.p. 91 290 com 11 19.9 x47.5 cm CU 0.3 mm 1 Carrent noce Desired none ................................. Patient Size 2 Acquisition Type Wall Stand 3 KV 121 Dose 1.25 Measuring Field Show More 2. Following the directions on the bottom left of the monitor, engage your exposure button half- way to allow the tube and detector to move into place. Messages (1) Press precontact to move to start position 3. Once the tube and detector are in place, another message will appear guiding you to tell the patient to hold still and then to release the acquisition (press the exposure button down com- pletely to begin imaging). The messages will inform you when each image is taken. Hold the button down until the images are done and the tube and detector are back in the starting po- sition. Messages (1) Messages (2) Messages (3) Instruct Patient to stop moving. Release mage 1 of 3. Keep acquisition switch acquisition and hold switch pressed Acquisition finished. Patient can move Wait. Transferring image. again. Keep switch pressed to move to start pos. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/21/2021 | HOOD05162003187756 Healthineers Page 3 of 4 Job Aid | Performing Ortho at the Wallstand Effective Date: 04/21/2021 | HOOD05162003187756 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitu te the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/21/2021 | HOOD05162003187756 Healthineers Page 4 of 4
- YSIO X.pree