PEPconnect

YSIO X.pree Re-composing Ortho Images

This job aid will guide users through the steps of how to re-compose ortho images.

YSIO X.pree: Re-composing Ortho Images XPRF Stitching/composing of the Ortho images is done automatically by the system. Stitching can be reviewed and re-composed in the “Viewing” tab. 1. Once all images are acquired, select the “Viewing” tab on the left side. The “Series Navigator” on the bottom right will display the individual images and the stitched image. Choose the stitched image and then select the “Composing” icon just above that in the “Static Tools”. Static Tools Series Navigator 2. Two images will appear in the center of the monitor. The one on the right is the full “Over- view” of the stitched image. Inside this image is a box that can be used to magnify areas of the stitched image. This box can be moved around to view different areas of the images. The one on the left is the “Detail Image”, the magnified view of the area inside the box on the right. The image can be “pinched” using two fingers to increase or decrease the size of it. Detail OVerview Image Image Composing Composing Controls Image Order Haul So Teut Transition Mode Cuit Bieng Static Tools Series Navigator 3. In rare cases where transition areas have not been optimally reconstructed by the system, or when the patient moves during imaging, adjustments can be made manually. To ensure opti- mal reconstruction, evaluate each image overlap and adjust if needed. Unrestricted 0 Published by Siemens Healthcare GmbH @ Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/21/2021 | HOOD05162003187759 Healthineers Job Aid | Re-composing Ortho Images Effective Date: 04/21/2021 | HOOD05162003187759 4. To do this, begin by choosing the “Cut” icon to see the overlap area more distinctly. 5. Next, adjust the box in the Overview image to better see the overlapping areas in the detail view. The white lines demonstrating the overlap area will turn orange when the box is moved over the corresponding overlap area. The orange lines represent the cut line being adjusted. Moving the box in the overview image to different image areas will allow for editing of different cut lines. 6. Use the editing tools to the right of the images make changes to the overlap areas. Images can be adjusted “side to side” or “up and down” via the arrows. Keep in mind that the number of pixels the image is adjusted is controlled by the “Step Size”. 7. When adjusting the uppermost overlap area, image number two will move in the direction of the button being selected. Any images attached below will move along with it. 8. Repeat these steps for any subsequent overlap areas that need adjustment. Composing Spconcession Algorithm - Composing Controls TOD (cml 14 Image Order Haal So Teut Foot to that Transition Mode tatic Tools Series Navigator 9. The newly composed images are saved automatically and can be sent to PACS in the “Distribution” tab. Unrestricted 0 Published by Siemens Healthcare GmbH @ Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 04/21/2021 | HOOD05162003187759 Healthineers Page 2 of 3 Job Aid | Re-composing Ortho Images Effective Date: 04/21/2021 | HOOD05162003187759 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be Liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 Unrestricted 0 Published by Siemens Healthcare GmbH @ Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 04/21/2021 | HOOD05162003187759 Healthineers Page 3 of 3