ACR MR Phantom - Locate Center Frequency and Transmitter Gain - Numaris X
This Job Aid provides workflow steps to locate the ACR MR Phantom Center Frequency and Transmitter Gain for Numaris X Software
ACR MR Phantom Locate Center Frequency & Transmitter Gain Numaris X ACR MR Phantom Images – locate Center Frequency (CF) & Transmitter Gain (TG) on Numaris X software. This Job Aid is not meant to replace the ACR documentation. Please refer to the MR ACR website. www.acr.org regarding the latest documentation for MRI ACR Phantom Testing. 1. Complete ACR Phantom Protocol Data Acquisition 2. Right Mouse on Last Sequence Run > select Repeat and Open a. Note: No other protocols can be planned or running in measurement queue Brain Dot Engine >LOC + + ACR Phantom Test ACR Sagittal Localizer 145345 IMA | FRY 13/25 ACR T1 ACR T2 ACR 11 Sile Protocol ACR T2 Sile Protocol Append Inser Append Pause .. Ctrl+Insert Insert Table Positioning Strategy Repeat Repeat and Open Rerun from here Rerun from here with Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/19/2020 | HOOD05162003096864 Healthineers Job Aid | ACR MR Phantom – Locate Center Frequency & Transmitter Gain Effective Date: 06/19/2020 | HOOD05162003096864 3. Locate and Document – Center Frequency (CF) and Transmitter Gain (TG) a. Select System > Tx/Rx Tab Frequency 1H – Center Frequency (CF) Ref. Amplitude 1H – Transmitter Gain (TG) @ 145min " Manual @2 107-0 7:40 mm2 Y 1.00 Routine Contrast Resolution Geometry System Physlo Sequence Coils Miscellaneous Adjustments Adjust Volume Transmitter Receiver Frequency 1H 121 200000 MH Image Scaling 1.000 % Ty Raf [Nulclans Raf Amplitude 1H 111.000 4 Correction Factor 1.00 Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 3 Job Aid | ACR MR Phantom – Locate Center Frequency & Transmitter Gain Effective Date: 06/19/2020 | HOOD05162003096864 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 3
- ACR MR Phantom
- Numaris X