
ADVIA Centaur® XP Immunoassay System Processing and Managing Samples Online Training
Processing and managing samples includes creating manual work orders, processing samples and identifying sample status. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the ADVIA Centaur® XP Immunoassay System Processing and Managing Samples Online Training course. In this course, you will learn how to process patient samples using the LIS and schedule patients if the LIS is not operational. You will also learn how to review patient results and print reports to keep for your records. Select Next to review the course objectives. Describe how to schedule patient samples with and without barcodes Explain how to print patient reports and review print options List the steps to export results to a CD or DVD List the steps to retransmit results to the LIS Review results in the Worklist Summary After completing this course, you will be able to: Select Next to continue. Congratulations. You have completed the ADVIA Centaur® XP Immunoassay System Processing and Managing Samples Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Tip: This page can be printed as a reference. In this online training course, you have learned to: Describe how to schedule patient samples with and without barcodes. Samples are ordered in the Worklist Schedule window. The Schedule by SID option can be used to schedule barcoded samples. The Schedule by Rack option can be used to order non-barcoded samples. Batches are scheduled by entering the Starting and Ending Rack numbers. STATs can be processed by using the STAT Entry or by selecting the STAT button in the Worklist Schedule Window. Explain how to print patient reports and review print options. Patient reports, Calibration and Maintenance logs are printed from the Report Options window. List the steps required to retransmit results to the LIS. Results are retransmitted from the Worklist Summary window by selecting the LIS Communications button. List the steps required to export results to a CD or DVD. Results are exported from the Maintenance window by highlighting Archive result data and pressing Perform. Review results in the Worklist Summary. Results can be evaluated by using the View, Sort and Search options. Select NEXT to continue. Schedule patients using: The LIS - The instrument requests orders from the LIS when samples are loaded into the Inprocess Queue Manual entry - Use when the LIS is not operational in your lab or for non-barcoded samples Batch mode - Use when the LIS is not available to order tests on a group of samples Note: Refer to the operating instructions in the laboratory for more details about LIS communication. Select Next to continue. Scheduling barcoded and non-barcoded samples is required when: The LIS is not available Barcodes cannot be read Schedule Barcoded Samples Learn how to schedule barcoded samples. Checklist TitleChecklist TypeChecklist ContentAccess Worklist ScheduleHTML From the Worklist dropdown menu, select Schedule. Select each checkbox to learn about scheduling barcoded samples. Enter SIDHTML Select the SID field, input the Sample Identification number (SID) and press the Enter key on the keyboard. Note: The sample barcode can be scanned in by the handheld barcode reader. Select the Scan Data button, scan the sample and the barcode will populate the SID field. Select TestHTML Choose an assay from the displayed menu and select Save. View Worklist Summary WindowHTML Use the Worklist Summary to confirm the accuracy of the entry. When complete, select the X in the upper-right corner to close the window and continue. Schedule Non-barcoded Samples Learn how to schedule non-barcoded samples. Checklist TitleChecklist TypeChecklist ContentAccess Worklist ScheduleHTML From the Worklist dropdown menu, select Schedule. Select each checkbox to learn about scheduling non-barcoded samples. Select Schedule by RackHTML Select Schedule by Rack. Observe Rack IDHTML Note the rack number and sample position. The rack number can be found at the end of the rack. The sample position letter is located above the sample position. This information will be entered in the Worklist Schedule window. Enter Rack IDHTML Select the Rack field and enter the rack number and sample position in the Worklist Schedule window. Press the Enter key on the keyboard. Note: The rack position letter that follows the rack number is case sensitive and must be Upper Case. Select TestHTML Choose an assay from the displayed menu and select Save. Note: To avoid sample misidentification, enter an SID in the SID field. The SID can be any combination of alphanumeric characters. View Worklist Summary WindowHTML Use the Worklist Summary to confirm the accuracy of the entry. When complete, select the X in the upper-right corner to close the window and continue. Processing Routine Samples: Load racks onto the Sample Entry Queue Press the Start button to begin system initialization The system status changes from Ready to Inprocess Racks are loaded into the Inprocess Queue and processing begins Use the Worklist Summary to review samples in process Use the Sample Status window to address samples without barcodes or orders When sampling is complete, racks are loaded into the Exit Queue Process Routine Samples Select this link to learn about processing routine samples. Checklist TitleChecklist TypeChecklist ContentLoad SamplesHTML Place sample rack on the Sample Entry Queue. Select each checkbox to learn more about processing routine samples. Press StartHTML Press the Start button to initialize the instrument. The magnetic belt under the sample entry queue will begin to turn and move the sample racks to the right. Samples Enter Inprocess QueueHTML The sample racks are loaded into the Inprocess Queue where sampling will begin. The sample probe will use disposable tips to aspirate sample from the racks. View Worklist Summary WindowHTML Open the Worklist Summary window to review the orders of the samples you just loaded. As processing begins, a time due will appear on the worklist. View Sample Status WindowHTML If the Sample Status button starts blinking yellow, open the window to determine sample errors. The window lists all samples that are currently in the Inprocess Queue. Samples with errors will be highlighted yellow. Errors may include: No Barcode No Request Clot Detected Insufficient Integrity Error Note: For more information about sample status flags, refer to the ADVIA Centaur® XP Operator’s Guide. Samples Placed in Exit QueueHTML When samples have completed processing, they are removed from the Inprocess Queue and placed in the Exit Queue. When complete, select the X in the upper-right corner to close the window and continue. You have just learned how to schedule barcoded and non-barcoded samples. Select the links below to practice what you have learned. Your Turn Practice scheduling non-barcoded samples. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003315/sim_CXP_SchedNonbarPatient800x622_9/sim_CXP_SchedNonbarPatient800x622_9.swfHTML5 File:/content/generator/Course_90003315/sim_CXP_SchedNonbarPatient800x622_9/index.htmlPDF File: Your Turn Practice scheduling barcoded samples. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003315/sim_CXP_SchedBarcoded800x622_9/sim_CXP_SchedBarcoded800x622_9.swfHTML5 File:/content/generator/Course_90003315/sim_CXP_SchedBarcoded800x622_9/index.htmlPDF File: Worklist Summary: Review the list of orders Evaluate the sample results View the time due for pending tests Customize the display to view specific orders Worklist Summary Select this link to learn about the Worklist Summary. Base ImageHotspotsText BlocksImage File Use the Sort dropdown menu to customize the view. Use the View dropdown menu to view samples by category. Select the search option from the dropdown menu and enter a keyword or number. Note: The Search for field entry must match the category from the dropdown list above the field. Reviewing Results Select this link to learn how to review results. Checklist TitleChecklist TypeChecklist ContentObserve Time DueHTML Open the Worklist Summary window to review worklist orders of the samples you just loaded. If any samples are still in process, a completion time will appear on the window. Select each checkbox to learn about reviewing results. Review ResultsHTML When samples are complete, the result will be displayed on the right side of the window. Check for FlagsHTML If there was an issue with a sample, a flag will be listed to the right of the result. Flags may include: > Conc Range < Conc Range Control bracketed Diluted Insufficient System Error No Primary Note: For more information about result flags, refer to the ADVIA Centaur® XP Operator’s Guide. Open Result Details WindowHTML The Result Details button provides additional information about a result. This information includes: Replicate and mean results Reference ranges Units Complete list of flags for each result Access to reagent lot and pack information for each result Note: For more information about result details, refer to the ADVIA Centaur® XP Operator’s Guide. Open Exit Queue WindowHTML You can use the Exit Queue window to locate samples that do not have results, require dilutions or require further attention due to errors. This window displays the 48 most recently ejected sample racks. When complete, select the X in the upper-right corner to close the window and continue. Exporting Results: Patient, control and calibrator results can be exported to a CD or a DVD Use the Archive result data procedure in the Maintenance status window Retransmitting Results to the LIS: Patient and control results can be retransmitted to the LIS Use the LIS Communications button in the Worklist Summary Exporting Results Select this link to learn how to export results to a CD. Checklist TitleChecklist TypeChecklist ContentInsert CDHTML Insert a writable CD or DVD into the top CD drive. Select each checkbox to learn about exporting results. Select Archive Result DataHTML Open the Maintenance status window and select Archive result data. Press PerformHTML Press Perform, choose the appropriate options and select Continue. When complete, select the X in the upper-right corner to close the window Retransmitting Results to LIS Select this link to learn about retransmitting results to the LIS. Checklist TitleChecklist TypeChecklist ContentAccess Worklist SummaryHTML Open the Worklist Summary window. Select each checkbox to learn about retransmitting results to the LIS. Select LIS CommunicationsHTML Select the LIS Communications button. Choose OptionsHTML Select the appropriate options and press Continue. Note: The LIS must be turned on in the System Setup window for the LIS Communications button to be active. When complete, select the X in the upper-right corner to close the window and continue. Practice Retransmitting Results to LIS Select this link to practice retransmitting results to the LIS. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003315/sim_CXP_Retransmit800x622_9/sim_CXP_Retransmit800x622_9.swfHTML5 File:/content/generator/Course_90003315/sim_CXP_Retransmit800x622_9/index.htmlPDF File: Print options: Report Options Print Workspace Cancel Reports Activate runtime reports Select this link to learn how to activate runtime reports. Checklist TitleChecklist TypeChecklist ContentSelect Report OptionsHTML Select the Print function button and select Report Options. Select each checkbox to learn how to activate runtime reports. Select SetupHTML Select the Setup button. Choose Runtime ReportsHTML The Runtime Report prints sample results as they are generated by the system. To turn Runtime Reports on: Press the Automatic Runtime Results Report button Select Save When complete, select the X in the upper-right corner to close the window and continue. Print reports Select this link to learn how to print reports. Checklist TitleChecklist TypeChecklist ContentChoose Report OptionsHTML Select the Print function button and select Report Options. Select each checkbox to learn about printing reports. Print Calibration DataHTML Select Calibration Data. Select a starting and ending date and press Enter. Calibration data within the selected date range display in the table below the date fields. To print all of the calibration data for the selected date range, select Print All. To print data for one or more calibration instances, select the calibrations in the table and then select Print Selection. Print Results ReportHTML The Results Report is a report of all samples in a specific date range according to the specified view and sort options. Select Results Report. Enter the starting and ending dates, view and sort. Select Print Report. Print Maintenance LogHTML You can print a report of either the scheduled maintenance for the system or the maintenance log. Select Maintenance. Select the Schedule or Log. If you selected log, enter the starting and ending dates. Select Print Report. When complete, select the X in the upper-right corner to close the window and continue. Processing STAT patient samples: LIS - STAT orders received are given priority over routine samples STAT Entry - Samples are given priority over samples loaded onto the Sample Entry Queue STAT button in Worklist Schedule - Enter the SID and select the STAT button Processing STAT Samples Select this link to learn how to process STAT samples. Slide NumberText BlocksCalloutsAudio ScriptImage File1STAT Entry Load samples in the STAT entry that require processing before samples in the sample entry queue. Select Next to continue. Tip: If audio does not automatically start, select the play arrow in the top left to begin.You can load STAT samples in the STAT Entry. The system automatically processes these samples before the routine samples that are loaded in the sample entry queue. All samples in the rack loaded in the STAT entry are processed before samples loaded in the sample entry queue. Select next to continue.2STAT button in Worklist Schedule Create a new order: Open the Worklist Schedule window Enter the SID Press Enter on the keyboard Select the STAT button Select tests Press Save Edit an existing order: Open the Worklist Summary window Select the order Press the Schedule button Select the STAT button Press Save Select Next to continue. STAT samples can also be scheduled manually in the Worklist Schedule window. You can either edit an existing order or create a new one. To create a new STAT order, open the Worklist Schedule window. Enter the accession number in the SID field and press enter on the keyboard. Select the STAT button and then choose the tests to be processed. Finally, press the Save button to store your STAT order. To edit an existing order, select the order in the worklist summary and press the Schedule button. Select the STAT button to the right of the Rack field and press save. Select next to continue.3STATs in Worklist Summary: STATs are flagged with an exclamation point (!) STATs view can be used to see only STAT orders Tip: When complete, select the X in the upper-right corner to close the window and continue.Stats in the worklist summary are flagged by an exclamation point to the left of the SID. The view can be changed to just see stat orders. Scheduling by batch mode: Schedule multiple tests on a group of barcoded samples Use when the LIS is not available or for a group of samples not being processed through the LIS Order a batch in the Worklist Schedule window Schedule a Batch Select this link to learn how to schedule a batch. Checklist TitleChecklist TypeChecklist ContentAccess Worklist ScheduleHTML From the Worklist menu, select Schedule. Select each checkbox to learn more about scheduling a batch. Select BatchHTML Select the Batch radio button. Enter Starting and Ending RackHTML Enter the 4 digit number for the starting and ending racks. These numbers can be found on the end of each rack. Note: Racks do not have to be in sequential order. Select TestsHTML Select the test or tests to be processed in this batch. Select SaveHTML Press the Save button. View Worklist SummaryHTML Review your order in the Worklist Summary window. Open the View drop-down menu and select Pending Batches. Change the Sort option to Rack to view the ending rack number. As samples are scanned, individual requests are added to the worklist. When the system scans the ending rack, the batch is removed from the Pending Batches view. Note: If you need to process a sample that is not part of the batch, use the STAT entry. Any sample placed in the STAT entry will not be included in the scheduled batch. When complete, select the X in the upper-right corner to close the window and continue. Scheduling Batches Select this link to practice scheduling a batch. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90003315/sim_CXP_ScheduleBatch_9/sim_CXP_ScheduleBatch_9.swfHTML5 File:/content/generator/Course_90003315/sim_CXP_ScheduleBatch_9/index.htmlPDF File:
- centauro
- centuar
- centuarxp
- centaurxp
- centauroxp
- centuarxp
- cenatur
- cenaturxp
- cen
- cenxp
- centar
- centarxp
- centau
- centauer
- centauerxp
- centure
- centurexp