ADVIA Centaur® XP Immunoassay System Competency Checklist
Education resource material designed to document competency mastery on-the-job. This Competency Checklist represents all learning objectives for this training area.
ADVIA Centaur® XP Immunoassay System Competency Checklist Once an employee has acquired the necessary knowledge and skills to perform basic operation tasks this checklist can be used to observe the employee perform the required tasks for their core job responsibilities and to document demonstrated competency. The observer places their initials and date beside the task when it is performed successfully. Successful completion for each task is determined by the facility. The standards used to evaluate can be documented in the “Criteria” section below. Use the area below to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. When all required tasks are completed, the supervisor and employee sign and date this document as a record of completion. Use the area on the last page to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. Criteria - Standards for successful completion of each task (e.g. Accuracy, Time, Quality, etc.): Observer’s Initials and Completion Date Topic/Tasks Hardware Overview Identify system exterior components and compartments Identify system interior components Identify the system fluids Software Overview Log onto the ADVIA Centaur CP software Locate key Status, Task, and Function buttons Use the Help button to access Online Help information Supplies and Reagent Management Load Acid, Base, and Wash 1 Reagents Load/Remove Primary and Ancillary Reagents Load sample tips Load cuvettes Replace/refill DI Water Empty Liquid waste Empty Tip, Tip Tray, and Cuvette waste Sample Processing Manually create orders using the Worklist Schedule screen Schedule a STAT sample Schedule a Batch View test orders in the Worklist Summary screen Start a sample run Review results in the Worklist Summary screen Print results reports Activate Runtime Reports Archive results Additional Worklist Functions Schedule System-performed and Manual dilutions Create a dilution profile Quality # HILS1913 Effective Date: 06/09/2017 Page 1 of 3 SIEMENS siemens.com/healthineers Healthineers ADVIA Centaur® XP Immunoassay System Competency Checklist Schedule replicates on a patient samples using Reagent Options Schedule a repeat on a patient sample Add patient demographics Add a comment to an order Calibration Check Calibration status Locate and scan a Master Curve card Locate and scan a Calibrator Assigned Value card Process a calibration Review calibration data Print calibration data ADVIA QC version 2.5 View QC data, graphs, and statistics Print QC data reports QC data reports Configure setup options ADVIA QC version 3.2 View QC data, graphs, and statistics Print and customize QC data reports Export QC data Configure setup options Quality Control Add a new quality control definition Edit a quality control definition Delete a quality control definition Schedule and process QC samples View QC Data Create a QC Test Profile Maintenance Locate, review, and update the Maintenance Window and access procedures through Online help List the steps to perform the daily maintenance procedures Describe how to perform the weekly maintenance procedures List the steps to perform the monthly maintenance procedures Describe the as needed maintenance procedures Basic Troubleshooting Access the Event Log Utilize the Event Log to investigate a specific system error State how to troubleshoot common system errors EHIV List the steps required for EHIV calibration Define EHIV QC Describe how to process patient samples Troubleshoot the loss of patient data Quality # HILS1913 Effective Date: 06/09/2017 Page 2 of 3 SIEMENS Healthineers siemens.com/healthineers ADVIA Centaur® XP Immunoassay System Competency Checklist Comments Areas of Improvement Next Steps Primary Operator Secondary Operator has been trained on the above documented tasks Supervisor: Employee: Date: Quality # HILS1913 Effective Date: 06/09/2017 Page 3 of 3 SIEMENS Healthineers siemens.com/healthineers
- advia
- centar
- sentar
- competency
- training
- mentor
- checklist
- consolidated