AI-Rad Companion - Cardiovascular Workflow
AI-Rad Companion - Cardiovascular Workflow
Cardiovascular Workflow Job Aid AI-Rad Companion This document introduces the workflow steps with the Cardiovascular extensions in AI-Rad Companion. 1. Cardio functionality 1. After activating the Cardio functionality, scroll through the data set in the 2D segment in order to see the yellow patches indicating coronary calcium. SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Healthineers Job Aid Effective Date: 09/30/2019 | HOOD05162003039618 Job Aid | Cardiovascular Workflow – AI-Rad Companion Effective Date: 09/30/2019 | HOOD05162003039618 2. The 3D segment also shows the heart segments affected by coronary calcium with yellow patches. 3. The table below the 3D segment shows the amount of calcium and heart volume. Cardio Result State Coronary Calcium 127.0 mm3 Accepted v Heart Volume 827.3 ml Accepted v Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 7 Job Aid | Cardiovascular Workflow – AI-Rad Companion Effective Date: 09/30/2019 | HOOD05162003039618 4. Decide for all findings to accept or decline them by clicking the button corresponding to your decision: Click Decline All if you disagree with the findings. They will be marked as declined in the Results list, will be deleted and will not be sent to the PACS. Leave the state on Accepted if you accept the finding. V Accept All Decline All 5. At any time during the workflow you can suspend the case by clicking on the Suspend button. In this case you can return to the To be Confirmed list. If you then open the patient case again, all your prior decisions on the findings will be shown. If you made all your decisions on the findings, click the Send to PACS button. The patient case will be closed and the data will be sent to the PACS. Suspend Send to PACS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 7 Job Aid | Cardiovascular Workflow – AI-Rad Companion Effective Date: 09/30/2019 | HOOD05162003039618 1. Vascular functionality 1. After activating the Vascular functionality, in the 3D segment you can see the segmented images of the aorta with nine landmarks, defined by the American Heart Association. 1/8 AL 2. Scroll through the nine cross-sectional images at these landmarks in the 2D segment. In each image the maximum aortic diameter is displayed. 119 36 mm Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 4 of 7 Job Aid | Cardiovascular Workflow – AI-Rad Companion Effective Date: 09/30/2019 | HOOD05162003039618 3. The table below the 3D segment shows the diameters for each landmark. These diameters are automatically compared to threshold values predefined in the Configuration menu and are color-coded if these thresholds are exceeded. The categories are based on reference values measured on a large number of patient population at each landmark. Reference: 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM Guidelines for the Diagnosis and Management of Patients with Thoracic Aortic Disease. Index Landmark Diameter State [mm] 1 Aortic Sinuses of Valsalva 38 Accepted v 2 Sinotubular Junction 37 Accepted v 3 Mid Ascending Aorta 36 Accepted 4 Proximal Aortic Arch 35 Accepted v 5 Mid Aortic Arch 32 Accepted 6 Proximal Descending Thoracic Aorta 30 Accepted v 7 Mid Descending Aorta 30 Accepted 8 Aorta at Diaphragm 29 Accepted v 9 Abdominal Aorta 27 Accepted v Vascular Category Il 4. Decide for all findings to accept or decline them by clicking the button corresponding to your decision: Click Decline All if you disagree with the findings. They will be marked as declined in the Results list, will be deleted and will not be sent to the PACS. Leave the state on Accepted if you accept the finding. V Accept All Decline All Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 5 of 7 Job Aid | Cardiovascular Workflow – AI-Rad Companion Effective Date: 09/30/2019 | HOOD05162003039618 5. At any time during the workflow you can suspend the case by clicking on the Suspend button and return to the To be Confirmed list. If you then open the patient case again, all your prior decisions on the findings will be shown. If you made all your decisions on the findings, click the Send to PACS button. The patient case will be closed and the data will be sent to the PACS. Suspend Send to PACS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 6 of 7 Job Aid | Cardiovascular Workflow – AI-Rad Companion Effective Date: 09/30/2019 | HOOD05162003039618 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 7 of 7
- AI-Rad Companion - Cardiovascular Workflow