AI-Rad Companion - Confirmation Workflow - Prostate MR Job Aid
This PDF provides you an overview of the steps within the Prostate MR workflow.
Prostate MR Confirmation Workflow AI-Rad Companion The AI-Rad Companion Prostate MR extension provides quantitative and qualitative information, such as the prostate volume and manually segmented lesions based on prostate MR DICOM images. Prerequisites: Software version VA20A and later - Images must be acquired with 3T or 1.5T MR systems with an endo-rectal or body coil - Patients age ≥ 18 years old - T2 Turbo Spin Echo or T2 SPACE is needed for prostate segmentation - Image data must be free from severe artifacts due to implants or motion causing - degradation of image quality Patients who have not undergone partial prostate resection or prostatectomy - Please note: Enhanced MR images are not supported. SIEMENS Healthineers Al-Rad Companion R 1 2010IMST Prostate MR @ T. Gland volume Gland Volume 64.29 Patient Info PSA PSA John Doe 1952-01-01 Male PSA density PSA Density ID: 3T Scan: 2017-11-21 08:31 Structur Slice Range Actions Prostate 2 Al Results Prostate V Decline Send to PACS Show All Contours C702 W 132 A V 1. After activating the Prostate MR extension, you can view and review the segmentation results in the Result Preview. The 2D segment displays the automatic segmentation of the prostate gland, provided by the deep learning algorithm. 2. The result table on the right side lists the slices where the prostate contours and manually added lesions are available. Job Aid | Prostate MR Confirmation Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 2.1 Add lesion contours a) Click at the Create lesion button below the 2D image segment. The placeholder Creating new lesion is displayed in the results table on the right side. Prostate MR Z2.1 15122 Gland volume Chard whom Patient Info PSA John Doe 1952-01-01 Male PSA density PSA Dentity ID: 3T Scan: 2017-11-21 08:31 Structure lice Range Actions Prostate 3-20 Creating new lesion Al Results Prostate Decline Send to PACS Show All Contoun C702 / 1321 A V b) In order to define the new lesion, click in the image to draw the lesion contour with the mouse cursor. Double click to complete the contour. The new lesion contour is displayed as a dotted line. Each dot can be adjusted before confirming the lesion. c) For lesions that span several slices the contour needs to be created for each slice separately. Complete your contour creation by selecting the Confirm button below the 2D image. d) After creating and confirming a lesion, you can return to editing a lesion. Select the lesion in the table on the right and click on the edit button. After adjusting the contour click Confirm. SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 24 SEP 2020 | HOOD05162003127044 Job Aid | Prostate MR Confirmation Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 2.2Adjust prostate segmentation and lesion contours a) Click on the contours you want to edit in the table and click on the Edit button in the Actions column. You can edit the prostate segmentation as well as any lesion you have created. b) A white- dotted line will appear at the 2D segment image and you can move the dots to adjust the contour line. The correction only corrects the current slice and is not a 3D correction. c) Select Confirm V to save the new contour. Prostate MR @ Z-27.9 Gland Volume 5122 Gland volume 64.29 Patient Info PSA John Doe 1952-01-01 Male PSA density PSA Density ID: 31 Scan: 2017-11-21 00:31 Structure Slice Range Actions Prostate 3-20 Al Results Prostate Declina sand to PACS C702 W 1321 A V SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 24 SEP 2020 | HOOD05162003127044 Job Aid | Prostate MR Confirmation Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 2.3 Delete lesion contours a) To delete a contour, click the Delete icon in the Actions column of the corresponding contour line. b) Select One contour to delete the contour of the image of the currently selected slice. c) Select All contours to delete all contours of this lesion across all slices. Click the Delete button. 3. After completing the editing, you can accept or decline the results by clicking the button corresponding to your decision. a) Click Decline All if you disagree with the findings. They will be marked as declined in the Results list, will be deleted and will not be sent to the PACS. Decline All Send to PACS b) If you made all your decisions on the findings, click the Send to PACS button. The patient case will be closed, and the series will be sent to the PACS. Send to PACS SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 24 SEP 2020 | HOOD05162003127044 Job Aid | Prostate MR Confirmation Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers
- ai-rad-companion
- ai
- companion
- artificial
- intelligence
- confirmation
- workflow
- software
- overview
- prostate