Brain MR Results Configuration Workflow Job Aid
This PDF provides you an overview on the Brain MR Results Configuration menu of the AI-Rad Companion.
Brain MR Results Configuration Workflow AI-Rad Companion 1. Open the configuration tabs by clicking on the Settings icon in the Access bar. G ? 2. In the configuration menu you can activate the calculations and determine if the results shall be sent to PACS directly, or if they require manual confirmation in the Results preview. The configuration menu comprises the following areas: 1 Brain MR . Data Transfer 2 Send Al results automatically to PACS Deviation Map Label Map Data Selection Automatic data selection User defined selection Selection is based on the following series description: 3 Series description Process image data that meets ADNI standard Visualization Deviation Map Label Map Overlay transparency (%) Sherlay transparency (%) Deviations Deviation Map Colors Max. Deviations E Percentile Threshold E'I Min. Deviations Z-Values Threshold @ Percentiles for volumes 4. * - Values outside of normative range 5 Changes made apply to all users and will come into effect for the next processed case Cancel Save Job Aid | MR Brain Results Configuration Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 1. Brain MR toggle button Activate the Brain MR toggle button to enable the calculation of results. The result settings are then displayed and can be configured. 2. Send AI results automatically to PACS Activate the Send AI results automatically to PACS option to send the results to the PACS without review and confirmation. If required, you can specify the results that will be sent to the PACS by selecting Deviation map or Label map. 3. Data Selection If you want to use the default DICOM attributes to select the proper series that will be processed select Automatic data selection. By selecting User-defined data selection you can enter the required series description of the series that will be processed. Activating Process image data that meets ADNI standard verifies whether the protocol parameters of the input images are compliant the ADNI protocol guidelines in order to ensure sufficient image quality. 4. Visualization and Deviation Map Colors Under the Visualization settings you can change the Overlay transparency (%) values for deviation and label map. This adjustment defines the blending ratio between the original MR image and the resulting maps. You can also adjust the colors of the deviation map by selecting the required color range from the drop-down color palettes. SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 24 SEP 2020 | HOOD05162003127044 Job Aid | MR Brain Results Configuration Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 5. Threshold Define the percentile threshold value that defines the normative range. 6. Save and Cancel button Click the Save button to apply your settings and to go back to the Results Preview. The changes will be applied for the next incoming data. SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 24 SEP 2020 | HOOD05162003127044 Job Aid | Brain MR Results Configuration Workflow Effective Date: 24 SEP 2020 | HOOD05162003127044 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers Unrestricted
- ai-rad-companion
- ai
- companion
- artificial
- intelligence
- confirmation
- workflow
- software
- overview
- brain
- mr