How to Create an Arrhythmic HR Protocol
How to Create an Arrhythmic HR Protocol step by step
How to Customize a Coronary CTA - Arrhythmic Heart Rate Protocol Computed Tomography When scanning Coronary CTA exams on patients with high heart rate variability (e.g. >10 bpm), standard protocol settings could result in higher-than-expected radiation dose values, and end- diastolic reconstructions could likely to be non-diagnostic. By adapting several default acquistion and reconstruction parameters into a new protocol specifcially for these arrhythmic patients, it is more likely that dose will be minimized and diagnostic outcomes improved. ** Note: These instructions are intended for use on the SOMATOM Definition Flash with syngo CT2012A software and the SOMATOM Force with syngo CTVA50A software only. 1. Beginning with a Siemens' default Spiral or Adaptive Sequence cardiac protocol, adjust the following parameterson the Trigger subtask card: Switch to ms (milliseconds) for both the acq Topogram Heart Rate (bpm) Min: 52 Max: 122 Avg: 82 FI_CorCTA RT . 120 53 122 . 85 55 . 117 52 . 115 . 52 Pause DS_CorAdSeq RT] Pause DS_CorAdSeq RT 3 Adaptive Cardio Seq. BestPhase BestSyst Scan 250to 450 2 Phase Start 350- Pulsing manual Unit ms Range 300 to 400 4| Unit ms Recon quick 66 ms Load Hold Recon Recon Routine Scan Recon Auto Tasking Trigger Scan from 250 to 450 ms. Topogram Heart Rate (bpm) Min: 52 Max: 122 Avg: 82 FI_CorCTA RT . 120 53 . 122 . 85 55 117 . 52 . 115 52 Pause . DS_CorAdSeq RT Pause DS_CorAdSeq RT 3 Adaptive Cardio Seq. BestPhase BestSyst Scan 250 to 450 2 Phase Start 350 Pulsing manual Unit ms Range 300 400 Unit ms Recon quick 66 ms Load Hold Recor Recon Routine Scan Recon Auto Tasking Trigger SIEMENS siemens.com/healthineers Healthineers Job Aid | How to Customize a Coronary CTA - Arrhythmic Heart Rate Effective Date: 12/26/2017 | Quality HOOD0516200223102 Set the Pulsing to manual Topogram Heart Rate (bpm) Min: 52 Max: 122 Avg: 82 FI_CorCTA RT 120 53 .122 . . 115 . 52 Pause DS_CorAdSeq RT] Pause R DS_CorAdSeq RT 3 Adaptive Cardio Seq. v BestPhase BestSyst Scan 250to 450 =| Phase Start 350 KH Pulsing manual Unit ms Range 300 400 2 Unit ms M Recon quick 66 ms Load Hold Recon Recon Routine Scar Recon Auto Tasking Trigger Set the pulsing Range from 300 to 400 ms Topogram Heart Rate (bpm) Min: 52 Max: 122 Avg: 82 FI_CorCTA . 120 . 53 . 122 . 85 55 . 117 52 . 115 52 Pause . DS_CorAdSeq RT] 2 Pause DS_CorAdSeq RT 3 Adaptive Cardio Seq. v BestPhase BestSyst Scan 250to 450 Phase Start 350 Pulsing manual Unit ms Range 300 to Unit ms M Recon quick 66 ms Load Hold Recon Reco Routine Scan Recon Auto Tasking Trigger BestPhase should be set to BestSyst Topogram Heart Rate (bpm) Min: 52 Max: 122 Avg: 82 120 . 53 .122 . 85 55 FI_CorCTA RT . 117 . 52 . 115 . Pause DS_CorAdSeq RT] Pause N DS_CorAdSeq RT Adaptive Cardio Seq. v. BestPhase BestSyst Scan 250 450 Phase Start 350 =| n' Pulsing manual Unit ms Rang 300to 400 Unit ms Recon quick 66 ms Load Hold Recon Recon Routine Scan Recor | Auto Tasking Trigger 2. If desired (and user has appropriate authority), save as a new protocol for future use. Siemens Healthineers Services Page 2 of 3 Job Aid | How to Customize a Coronary CTA - Arrhythmic Heart Rate Effective Date: 12/26/2017 | Quality HOOD0516200223102 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- CT
- Computed Tomography
- Arrhythmic HR Protocol