Atellica® Sample Handler Daily Maintenance PEP to Go Version 1.25 and Below

PEP to Go is an education resource material designed to support competency mastery on-the-job.

SIEMENS Healthineers Atellica® Sample Handler Daily Maintenance PEP to Go Effective Date: 3/12/2018 | HOOD05162002822815 Unrestricted © Siemens Healthcare GmbH, 2018 Atellica® Sample Handler SIEMENS Daily Maintenance Healthineers Daily Maintenance  Perform Sample Handler (SH) Autocheck  Perform Atellica Magline® Transport Autocheck 2 Effective Date: 3/12/2018 | HOOD05162002822815 Unrestricted © Siemens Healthcare GmbH, 2018 Atellica® Sample Handler SIEMENS Daily Maintenance Healthineers SIEMENS Build 1.7.0 DL-P1-07 Performing Automated SH Autocheck Activity 1 System Samples Inventory Calibration ac Patient Orders Worklist Maintenance Setup Schedule Report Log Diagnostics Data Restore Software Updates Copy Configuration The SH Autocheck is an automated maintenance activity 2 Filter Module: All Frequency: All Time: Next 24 hours Performed By: All that tests the health of various SH components. Module All Module Activity Scheduled Sun-28 Mon-29 Tue-30 Wed-31 Thu-01 Fri-02 Sat-03 4 Perform ... Frequency All CH GGCKKGSCI-CH IMT Daily Cleaning :: 05/31/2017 2:00 The system alerts the operator 15 minutes before the V V V Mark as Completed Time Next 24 hours CH GGCKKGSCI-CH CH Daily Maintenance : 05/31/2017 4:00 V V Not Perform .. scheduled activity begins. After the system initiates the SH Performed By All IM GGCKKGSCI-IM IM Autocheck 05/31/2017 3:30 V V V V Autocheck, the SH pauses sample processing until the Search Text Enter the activity name. SH GGCKKGSCI-SH SH Autocheck 3 Procedure Details .:: 05/31/2017 1:00 V V autocheck completes in approximately 5 minutes. Scheduled by Operator VMM Edit/View ... VMM Atellica Magline Transport Autocheck :!: 05/31/2017 1:00 V V Scheduled Automatically Scheduled by Service Database Backup :: 06/01/2017: 0:30 V V Delete The task will run automatically daily, but can be run IM GGCKKGSCI-IM Cleaning the Water Container 06/01/2017 1:00 V Failed manually if needed: Overdue GGCKKGSCI-IM Inspecting and Emptying the IM Water Trap :06/01/2017 1:00 V V Inprocess Database: Optimizing .:: 06/01/2017 3:00 V Completed IM 1. On the Command bar, select Maintenance GGCKKGSCI-IM IM Weekly Maintenance :06/01/2017 5:00 V V x Not Performed Database: Archiving and Deleting .:: 06/01/2017 7:00 -- -- 2. Select the Schedule tab With Comments IM Www Activibos GGCKKGSCI-IM Cleaning the Exterior of the Aspirate Probes 06/01/2017 7:00 IM 3. Select SH Autocheck GGCKKGSCI-IM Cleaning the Reagent Probe Rinse Stations 06/01/2017 8:00 Add Activity .. Set Warning. 4. Select Perform ? LabManager Monday, April 17, 2017 10:02 AM 5. Wait for autocheck to complete 3 Effective Date: 3/12/2018 | HOOD05162002822815 Unrestricted © Siemens Healthcare GmbH, 2018 Atellica® Sample Handler SIEMENS Daily Maintenance Healthineers SIEMENS Build 1.7.0 DL-P1-07 Performing Automated Atellica Magline® Transport System Samples Inventory Calibration ac 1 Patient Orders Worklist Maintenance Setup Autocheck Activity 2 Schedule Report Log Diagnostics Data Restore Software Updates Copy Configuration Filter Module: All Frequency: All Time: Next 24 hours Performed By: All The Atellica Magline Transport Autocheck is an automated Module All Module Activity Scheduled Sun-28 Mon-29 Tue-30 Wed-31 Thu-01 Fri-02 Sat-03 4 Perform ... maintenance activity that tests the health of various Frequency All CH GGCKKGSCI-CH IMT Daily Cleaning :: 05/31/2017 2:00 V V V Mark as Completed Atellica Magline Transport components. Time Next 24 hours CH GGCKKGSCI-CH CH Daily Maintenance : 05/31/2017 4:00 V V Not Perform .. Performed By All IM GGCKKGSCI-IM IM Autocheck 05/31/2017 3:30 V V V V Search Text Enter the activity name. SH Procedure Details The system alerts the operator 15 minutes before the GGCKKGSCI-SH SH Autocheck :: 05/31/2017 1:00 V Scheduled by Operator VMM scheduled activity begins. After the system initiates the Atellica Magline Transport Autocheck 3 VMM :!: 05/31/2017 1:00 V V Edit/View ... Scheduled Automatically Database Backup :: 06/01/2017:0:30 V V Delete Atellica Magline Transport Autocheck, the Atellica Magline Scheduled by Service IM GGCKKGSCI-IM Cleaning the Water Container 06/01/2017 1:00 V Transport pauses transporting samples until the Failed Overdue GGCKKGSCI-IM Inspecting and Emptying the IM Water Trap : 06/01/2017 1:00 V V autocheck completes in approximately 10 minutes. Inprocess Database: Optimizing .:: 06/01/2017 3:00 V Completed IM GGCKKGSCI-IM IM Weekly Maintenance :06/01/2017 5:00 V V The task will run automatically daily, but can be run x Not Performed Database: Archiving and Deleting .:: 06/01/2017 7:00 -- -- With Comments manually if needed: IM Www Activibos GGCKKGSCI-IM Cleaning the Exterior of the Aspirate Probes 06/01/2017 7:00 IM GGCKKGSCI-IM Cleaning the Reagent Probe Rinse Stations 06/01/2017 8:00 1. On the Command bar, select Maintenance Add Activity .. Set Warning. 2. Select the Schedule tab ? LabManager Monday, April 17, 2017 10:02 AM 3. Select Atellica Magline Transport Autocheck 4. Select Perform 5. Wait for autocheck to complete 4 Effective Date: 3/12/2018 | HOOD05162002822815 Unrestricted © Siemens Healthcare GmbH, 2018 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2018 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 5 Effective Date: 3/12/2018 | HOOD05162002822815 Unrestricted © Siemens Healthcare GmbH, 2018

  • attelica
  • attellica
  • atelica