Atellica® Solution Module Display Job Aid Version 1.25 and Below
This job aid provides instructions on how to use the functionality of the module display.
SIEMENS Healthineers Atellica® Solution Module Display Job Aid Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display Module Display • Each Chemistry and Immunoassay analyzer in a system configuration SIEMENS with a Sample Handler includes an affixed touchscreen module display Healthineers P1-06 LabManager Stopped • Allows the operator to perform analyzer specific functions directly at O the analyzer without having to use the primary user interface Module State System Fluids Supplies Waste • Each module display includes: • A built in barcode reader to scan system supplies and fluids 388 • A USB port that allows the operator to connect the Emergency Reagent Loader Sample Load (ESL) carrier barcode reader to scan samples during ESL operation* • The functions available to the operator include: • View and change the analyzer state • Lock and unlock analyzer covers *Note: ESL mode is an optional feature that allows the operator to continue • Check system fluids, supplies, waste (IM Analyzer), IMT supplies processing samples directly on an analyzer if there is failure of the Sample Handler, Tube Characterization Station, or Atellica Magline Transport. Refer to (CH Analyzer), and reagent loader status the Atellica Solution Online Help for more information. • Load system fluids and reagents 2 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display To view and change the analyzer state using the Module Display: 1. Select the Module State button on the Module Display home screen 2. The current state of the analyzer is displayed 3. Select the pause, stop or resume button to change the state of the analyzer SIEMENS CI-CH SIEMENS Module State LabManager Standby LabManager Standby 1 CI-CH 0 Front Cover Back Cover Unlock Cover Unlock Cover Module State System Fluids Supplies IMT Supplies 2 Standby 3 Connected to PCC Status ? Reagent Loader 3 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display To lock and unlock the covers using the Module Display: 1. Select the Module State button on the Module Display home screen 2. Select the Unlock Cover button for either the front or back cover SIEMENS CI-CH SIEMENS Module State LabManager Standby ¿ LabManager Standby 1 CI-CH 0 Front Cover Back Cover 2 Unlock Cover Unlock Cover Module State System Fluids Supplies IMT Supplies Standby Connected to PCC Reagent Loader Status ? 4 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display To check the system fluids using the Module Display: SIEMENS CI-IM › LabManager Off Select the System Fluids button on the module display home screen 1 1. OL 2. View the status of the system fluids Module State System Fluids Supplies Waste 3. If a system fluid bottle needs to be loaded, it can be scanned using the 888 module display scanner Reagent Loader IM Analyzer CH Analyzer SIEMENS System Fluids SIEMENS Healthineers System Fluids LabManager Off Off 2 0 10 O 11. Tighten the cap before removing O A Tighten the cap before removing the fluid container. 6 O 7 the fluid container. IM Acid IM Base 9 CH Conditioner CH Cleaner IM Cleaner 4 5 --- - 8 8 CH Diluent CH Wash IM Wash ? ? 5 -------------- ------- 7 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display SIEMENS CI-CH KJ To check the status of the pretreatment pack on the CH Analyzer LabManager Standby using the Module Display: 1 1. Select the Supplies button on the module display home screen Module State System Fluids Supplies IMT Supplies 2. View the status of the pretreatment pack 3. If a new pretreatment needs to be loaded, it can be scanned using the module display scanner Reagent Loader SIEMENS Supplies Pretreatment × LabManager Standby 3 Pretreatment Lot Lot Expiration --- 150 mm / 6 in OBS Instructions for Status --- scanning 2 Manual Entry ? 45º 6 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display To view the status of the IMT supplies on the CH Analyzer: 1. Select the IMT Supplies button on the module display home screen 2. View the status of IMT sensor and IMT Fluids SIEMENS CI-CH SIEMENS IMT Supplies i LabManager Standby LabManager Standby 1 2 0 -00 i To replace IMT Sensor and IMT Fluids, pause the IMT system by opening the IMT Supplies lid, and then scan or manually enter the IMT Sensor or IMT Fluid barcode. Module State System Fluids Supplies IMT Supplies TD-LYTE 1 2 IMT Sensor IMT Std B + Salt IMT Standard A 388 Bridge IMT Diluent Pause IMT Reagent Loader ? 7 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display To view the status of the supplies on the IM Analyzer: 1. Select the Supplies button on the module display home screen 2. View the status of the Tips, Cuvettes, and Water SIEMENS CI-IM SIEMENS Supplies ¿ LabManager Off LabManager Off 1 Tips 0 2 Packs Available to be Loaded: 3 V Ok Tips Trays in Storage: 3 Cuvettes Module State System Fluids Supplies Waste Ok 3 Water V Ok ? Reagent Loader 8 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display To view the status of the waste on the IM Analyzer: 1. Select the Waste button on the module display home screen 2. View the status of the Cuvette and Tip Waste, Tip Tray Waste, and Liquid Waste 3. If the tip tray waste needs to be emptied, use the Open Tip Tray Waste Drawer button to open the tip tray waste drawer SIEMENS CI-IM SIEMENS Waste ¿ LabManager Off LabManager Off 1 Cuvette and Tip Waste 0 2 Ok Module State System Fluids Supplies Waste Tip Tray Waste Ok Open Tip Tray Waste Drawer 3 Liquid Waste V Ok Reagent Loader ? 9 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Healthineers Module Display SIEMENS CI-IM To view the status of reagents in the reagent loader: LabManager Off C 1. Select the Reagent Loader button on the module display home screen Module State System Fluids Supplies Waste 2. View the status of the reagents in the reagent loader 1 888 Reagent Loader IM Analyzer CH Analyzer SIEMENS Reagent Loader SIEMENS Reagent Loader LabManager Off Reagents Lid Closed Standby Reagent Drawer 2 1 Clear All 2 6 5 4 3 2 1 Unlock 3 4 5 ? ? 10 Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2019 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 11 siemens.com/healthineers Effective Date: 8/23/2019 | HOOD05162003024179 Unrestricted © Siemens Healthcare GmbH, 2019
- attelica
- attellica
- atelica