Biograph™ Patient Browser Online Training
This online training describes the purpose of the syngo® Patient Browser, explains how to access the Patient Browser, identifies the patient databases and data levels, and demonstrates how to filter, sort, transfer, archive and delete patient data in the database.
Welcome to the Biograph Patient Browser Online Training course. This course will provide an overview of the syngo Patient Browser. The topics covered in this module will include: Accessing the Patient Browser Patient databases and data levels Sorting and filtering Sending data to another node Archiving and deleting data Upon successful completion of this course, you will be able to: Describe the purpose of the syngo Patient Browser and access the patient browser Identify the patient databases and data levels Demonstrate how to manage patient data Summarize how to export and import patient data Congratulations. You have completed the Biograph™ Patient Browser Online Training Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Describe the purpose of the syngo Patient Browser and how to access the patient browser The Patient Browser portal is where all the data management tools for archiving, deleting, exporting, sending, sorting, and filtering can be accessed To access the Patient Browser, select Patient > Browser from the menu bar Identify the patient databases and data levels The different patient databases include the Local Database, Scheduler, and Local Archive The three levels of data in the local database include the patient level, study level, and series level Demonstrates the steps on how to manage patient data Sending Data Select the patient, study, series, or images in the Patient Brower Select Transfer > Send To or click the Toolbar button Select a Network Node from the list Click Send Archiving Archive all data prior to deleting any data For online archiving, transfer data manually or automatically to a network node For offline archiving, transfer data to an external media (i.e. USB devices) Deleting Open the Patient Browser Select the date to delete Choose Edit > Delete or select the Delete button Select Yes to confirm Summarize how to export and import patient data Exporting Configure the export series types Export patient data to a CD/DVD or USB Importing Open the Patient Browser Select the applicable PET data Click Import The Patient Browser is a portal where you can access all of your data management tools which includes: Archiving Deleting Exporting Sending Sorting Filtering To access the Patient Browser, select Patient > Browser from the menu bar. Patient Browser Window Learn about the patient browser window. Base ImageHotspotsText BlocksImage FileBrowser ToolbarBrowser Main MenuNavigation AreaLocal Database AccessScheduler AccessExternal Media AccessData ListPatient FoldersStudy FoldersSeries Folders Patient Databases Learn about patient databases. Element HTML Local Database: The system stores all patient and examination data in a large local database. Scheduler: This database contains all patients who have been pre-registered. The content switches to a special list and displays all patients scheduled. Local Archive: This icon represents the selected external drive CD or DVD. 123 Sound File Audio ScriptThe types of databases are symbolized on the left-hand side of the navigation area. When a specific database icon is selected, the contents are displayed in the content area of the browser. The Local Database contains all of the patient data and the examination data on the large local database. The Scheduler contains all of the patients that have been pre-registered, for example from the HIS or RIS. There is also a Local Archive icon that is labeled by a DVD or CD, representing the external archive device that is inserted into the drive. Data Levels Learn about data levels. Element HTML3 Levels of data in the Local Database: Patient Level Study Level Series Level When the Series level is selected, image stamps or files will display at the bottom of the screen. These are called instances. Sound File Audio ScriptThere are three levels of data in the local database. The first level is the Patient Level. The Patient Level contains all of the studies or visits the patient has had in your department. When the Patient level is selected, the studies folder will appear. The second level is the Study Level. The Study level contains all of the data that is associated with that particular exam. When selected, the Series for that study will display. A series consists of an individual acquisition, reconstruction job, or post processing dataset associated with that exam. When the series is selected, image stamps or files will appear in the Content area at the bottom of the screen. These are called Instances. Instances are images or slices. When the Patient folder is selected, it will appear as opened. When the Study folder is selected, the icon will appear to have a file sticking out of the top of the Study folder. When the Series is selected, it is highlighted in blue. Double click the selected series to access the instances. The following tasks are involved with managing patient data: Exporting Importing Sending Deleting To configure export series types: Select Options > Configuration > PET Examination > Export Series Types Check series types for export Note: Series types will be automatically populated when PET/CT Export Tool is launched but they can be manually changed. Exporting Patient Data to a CD/DVD Learn about exporting patient data to a CD/DVD. Tab TitleTextVia Export to... To export patient data to a CD/DVD: Insert a blank CD/DVD into the syngo Acquisition Workplace Select the desired data series in the patient browser Transfer > Export To... within the Patient Browser menu Click Export Type the appropriate name in the label on Medium field within the Enter Label window Click OK to export the patient data from the workstation to the CD/DVD Via PET/CT Data Tool To export patient data to a CD/DVD using the PET/CT Export Data Tool: Insert a blank CD/DVD into the syngo Acquisition Workplace Select the desired data series within the browser Select Patient > Export PET/CT Data within the Patient Browser menu - or - Select the Export PET/CT Data button within the Patient Browser The PET/CT Export Tool window appears with the selected patient data populated Select H:\SiteData\CDBurn Click Export (export anonymously if desired) Select Options > File Browser Clear all jobs in the local and network queues Select Transfer > Record Offline Files Note: there is an option to include a DICOM Viewer Exporting Patient Data to a USB Learn about exporting patient data to a USB. To export patient data to a USB: Open Patient Browser and insert a USB into the syngo Acquisition Workplace Select the desired data series within the browser Select Patient > Export PET/CT Data within the Patient Browser menu - or - Select the Export PET/CT Data button within the Patient Browser Select the USB name from the Path drop-down menu Click Export and the PET/CT Export Data Tool closes automatically Monitor the status of the export via Transfer > Local Job Status The status of the job will change from Active to Completed Safely Eject the USB To import patient data: Open the Patient Browser Select the applicable PET Data Click the Import PET/CT Data button - or - Select Patient Select Import PET/CT Data to open the PET/CT Import Data Tool Click Import Prior to deleting any data, ensure the data has been archived. For online archiving of DICOM images and data to a network node such as a PACS terminal, data can be transferred manually or automatically For offline archiving on external media, the system is equipped with a DVD recorder to store data on USB devices. Data stored on external media or drives can be reimported at any time To delete patient data: Open the Patient Browser Select the date to delete Choose Edit > Delete or select the Delete button Select Yes to confirm To send data through the Network: Select the patient, study, series, or images in the Patient Browser Select Transfer > Send To or click the Toolbar button Select a Network Node from the list Click Send Sort options available are determined by the current selection: To sort patient level data, click on the Local Database icon on the left side of the Patient Browser To sort study level data, first click on the Patient level that contains the study data that you want to sort To sort series level data, first click on the Study that contains the series data you want to sort Once the desired level is determined, click on the Sort drop-down from the patient browser to view the available sort option. To apply an existing filter: Select the data level to apply the filter Select the Filter menu at the top of the screen Select one of the available filters To create a new filter: Select Options > Filter Settings To remove the filter: Select the data level then click Filter > Off Applying Filters Learn about conditions for applying filters. Once the data level is selected, click on the Filter menu at the top of the screen then select one of the available filters. To filter data based on ... Select ... only data that have not been archived Filter > Not Archived only data that have not been exposed to film Filter > Not Printed only data that have not been sent anywhere in the network Filter > Not Sent only data that have not been marked Filter > Not Marked only data that have been marked Filter > Marked Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Please proceed to the assessment.
- biograph
- mct
- 20 excel
- flow
- neurology
- cardiology
- oncology
- singo
- vision
- horizon
- biograph patient browser
- patient browser online training