CardioFreeze Introduction Job Aid
CardioFreeze™ is an option for new systems. Customers licensed with HD•Cardiac that upgrade to the VG70 version will be upgraded to CardioFreeze at no addition charge. The material in this Job Aid applies to Biograph™ mCT (VG70) and Biograph Vision™ systems.
CardioFreeeze Intro Job Aid Biograph™ mCT & Biograph Vision™ Description: CardioFreeze™ is an option for new systems. Customers licensed with HD•Cardiac that upgrade to the VG70 version will be upgraded to CardioFreeze at no addition charge. The material in this Job Aid applies to Biograph™ mCT (VG70) and Biograph Vision™ systems. CardioFreeze reduces image blur from both cardiac and respiratory motion by utilizing 100% of the counts in the reconstruction of each gate. CardioFreeze uses the image data to extract the patient’s breathing pattern, requiring only the ECG trigger for gating both the heartbeat and the respiratory movement. CardioFreeze allows for 24 times more counts in each frame to improve the signal to noise ratio and image quality. 1. Connect the ECG leads to the patient depending on your region. A respiratory triggering device is not necessary. 2. Choose the CardiacGatedMFL protocol. PET CardiacGatedMFL (Adult) B.PET Brain (Adult) Cardiac (Adult) CardiacGated_CardiacMat( CardiacGatedMFL (Adult) CardiacGatedMFL_Cardiac CardiACstadALL DAArkA 3. Remember CardioFreeze is an extension of the iterative reconstruction algorithm and is not available for Backprojection reconstructions. Recon range (bed) Begin 1 End 1 Output Image type Corrected Recon method Iterative+TOF Iterations 3 Subsets 21 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template Effective Date: 08/22/2017 | HOOD05162002647849 Job Aid Effective Date: 03/08/2019 | HOOD05162002979840 Job Aid | CardioFreeze Introduction Effective Date: 03/08/2019 | HOOD05162002979840 4. There are three potential replay types: Cardiac – conventional cardiac gating CardioFreeze Single – cardiac gating with 100% of the counts in each gate CardioFreeze Dual – cardiac gating with respiratory motion correction and with 100% of the counts in each gate To incorporate the respiratory motion correction, choose the CardioFreeze Dual mode. Recon job 1 2 3 4 5 6 7 8 Series description PET CardioFreeze 8 Gates Recon range (bed) Begin 1 End 1 Replay Type Gated Replay Mode CardioFreeze Dual Skip Beats 0 Cardiac CardioFreeze Single Bed Dela CardioFreeze Dual 1 30 390 Routine Scan Recon Auto Tasking Replay Trigger 5. On the Trigger task card, the number of gates can be changed. It is recommended to leave the duty cycle at 35. The duty cycle will influence the respiratory blurring but not image noise. Note: Additional reconstructions can be added to meet your clinical needs. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Job Aid | CardioFreeze Introduction Effective Date: 03/08/2019 | HOOD05162002979840 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019
- CardioFreeze Introduction Job Aid