CARE Profile
This job aid covers CARE Profile for the Somatom Definition Scanners |
CARE Profile Job Aid SOMATOM Definition Scanners CARE Profile allows for the visualization of the scan dose distribution as it applies to the planned scan range so it can be actively managed during the scan preparation and acquisition. CARE Profile displays alongside the topogram and gives a better understanding of the proposed real-time dose modulation. 10.10.02-14:33:03-DST-Specials H ..................... Hospital MAS 10.10.02-14:33:03-DST-1.3.1 ... SOMATOM Definition Flash 18-Nov-1858, 0, 151Y CT 2011A.1.01_P00 02-Oct-2010 H-SP 14:33:36.56 1 IMA 1 TOP SP -751.0 SP T: -/96.U SP 2: -1104.1 LEN: 308.1 GT: 0.0 FoV: 392 CE: 4/0 .. . .. . .. ....... R O KV 120 mA 35 TI 5.3 GT 0.0 512 0/0 W 358 T20f UOPO 1eva CARE Profile benefits: Visualization of the dose distribution along the topogram prior to the scan • Optimized dose distribution delivers higher image quality • Active dose management with intuitive visualization • SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Healthineers Page 1 of 4 Job Aid | CARE Profile Effective Date: 01/30/2018 | HOOD05162002767562 CARE Profile – Green Curve: If the CARE Profile Curve is green, the effective mAs needed for the scan can be applied by the scanner and no adjustment or compensation is necessary. The load button is available to proceed to scan. 10.10.02-14:33:03-DST-Specials ... H Hospita 10.10.02-14:33:03-DST-1.3.1 -18-Now 1858 0. 151Y SOMATOM Definition Flash CT 2011A 1.01 POD ............. 512 00. . . . . . . .. of uoPO teva ................ CARE Profile – Yellow Curve If the CARE Profile Curve is yellow, the effective mAs needed for the scan exceeds the system limit. The scan is invalid and action is required. The load button is NOT available to proceed to scan. 0.02-14.33.03-DST Specials SOMATON DIGER .............. 17X 35 OTOO 51200 SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Healthineers Page 2 of 4 Job Aid | CARE Profile Effective Date: 01/30/2018 | HOOD05162002767562 CARE Profile – Yellow Peak If the CARE Profile Curve displays a yellow peak, the system cannot deliver the necessary effective mAs for the entire scan range. It is possible to load the scan; however, image quality in the region of the yellow peak may be suboptimal. If the parameters are not adjusted and the scan is loaded, the yellow peak is “cut off” and the maximum mAs value is applied to that region. Typically, minor adjustments to the scan time or pitch will resolve this type of conflict. 10.10.02-14:33:03-DST-Specials H Hospital 10.10.02-14:33-03-DST-1.3.1 SOMATOM Definition Flash "18 Nov 1858. 0. 151Y CT 2011A 1 01 POO .......... 512010 ...................................... T207 UOPO 1eva .................. CARE Profile – Green Striped Peak If the CARE Profile Curve displays a green striped peak, the system cannot deliver the requested effective mAs in that region; however, the exceedance is nominal and the reduction in image quality will be negligible. The load button is available to proceed to scan. min ............................................................. 9 TEST, PATIENT H 01234567 Hospital: mÁs SOMATOM Definition Flash *23-Oct-1950, O, 62Y CT 2012B 23-Oct-2012 H-SP 19:57:01.64 1 IMA 1 TOP SP -751.0 SP 1: -7610 SP 2; -1057.0 LEN: 306.0 GT: 0.0 FOV: 500 CE: 0/0 ................. ER O 10cm ........................ GT 0} - :512 0/0 T2Of JOPO 1eva__ 350 SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Healthineers Page 3 of 4 Job Aid | CARE Profile Effective Date: 01/30/2018 | HOOD05162002767562 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 4 of 4
- CARE Profile
- Somatom Definition