Cleaning the Atellica® Sample Handler Sample Drawers and Racks Job Aid Version 1.25 and Below
This job aid provides instructions on how to perform the as needed maintenance task of cleaning the Atellica® Sample Handler sample drawers and racks.
Cleaning the Sample Drawers and Racks on the SIEMENS Healthineers Atellica® Sample Handler Job Aid CIEMENC Build 8 6.1 SH-P1-01 SH-P1-01 Cleaning the SH Sample Drawers and Racks K System Samples Inventory Calibration OC Patient Orders Worklist Maintenance Setup Status Logs CC/DL Operator The operator must clean the SH sample drawers and racks as needed to Diagnostics Operator Diagnostics About PEPconnect ensure proper operation and prevent contamination of samples. System VMM SH-P1-01 CH IA-03 1. Stop the SH: Standby Standby Standby Stopped A. Navigate to the SH Status screen: System > Status > SH icon Alert Category Time Capabilities B. Select the Stop button V. Robot V TCS 2. Open all SH drawers V Cal-QC Storage V Cal-QC Storage Temperature 3. Unload all racks from the SH drawers B PCC V Drawer 1 V Drawer 2 II V Drawer 3 * This procedure is continued on the next slide. Unlock Front Cover V. Drawer 4 ¥ Front Cover Unlock Back Cover V Back Cover NOTE: Do not reach into the SH when sample drawers are open. The SH robot moves with high speed and force and can cause severe bodily harm. ? LabManager2 Tuesday, February 28, 2017 10:14:41 AM NOTE: Do not open the sample drawer without using caution. Opening or closing the sample drawer too quickly or forcefully can damage the drawer self-closing mechanism or cause splashing of the samples. Open or close the sample drawer slowly. Template Effective Date: 10 Aug 2021| HILS 2223 1 Effective Date: 06-JUN-2022 | HOOD05162003275357 Unrestricted © Siemens Healthineers, 2022 Cleaning the Sample Drawers and Racks on the SIEMENS Healthineers Atellica® Sample Handler Job Aid Cleaning the SH Sample Drawers and Racks (continued) 4. Clean the interior of each drawer: A. Wipe the area with lint-free tissues or gauze saturated with a 10% bleach solution B. Wipe the area with lint-free tissues or gauze saturated with water C. Dry the area thoroughly with clean lint-free tissues or gauze D. Dispose of contaminated cleaning supplies per laboratory protocol 5. Remove all sample containers from racks before cleaning 6. If the rack requires only routine cleaning: A. Wipe the rack with lint-free tissues or gauze saturated with a 10% bleach solution B. Wipe the rack with lint-free tissues or gauze saturated with water C. Dry the rack thoroughly with clean lint-free tissues or gauze D. Dispose of contaminated cleaning supplies per laboratory protocol NOTE: Take care when handling the sample racks, especially with the barcode labels and white localization dots on the top surface. The barcodes and white dots are used by the Drawer Vision System on the Sample Handler for tube identification and processing. 2 * This procedure is continued on the next slide. Template Effective Date: 10 Aug 2021| HILS 2223 Effective Date: 06-JUN-2022 | HOOD05162003275357 Unrestricted © Siemens Healthineers, 2022 Cleaning the Sample Drawers and Racks on the SIEMENS Healthineers Atellica® Sample Handler Job Aid Cleaning the SH Sample Drawers and Racks (continued) 7. If the rack is contaminated or has stuck-on debris that routine cleaning cannot remove: Note: this may be performed no more than once per week A. Soak the rack in a 10% bleach solution for no more than 5 minutes B. Rinse the rack thoroughly with water C. Dry the rack thoroughly with clean lint-free tissues or gauze, taking care around the barcode labels and white localization dots D. Dispose of contaminated cleaning supplies per laboratory protocol 10 8. Start the SH by selecting the Resume icon on the System Status screen 11 11 3 Effective Date: 06-JUN-2022 | HOOD05162003275357 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 4 Effective Date: 06-JUN-2022 | HOOD05162003275357 Unrestricted © Siemens Healthineers, 2022
- attelica
- attellica
- atelica