PEPconnect

CLINITEK Advantus® Urine Chemistry Analyzer Quality Control Online Training

QC testing verifies that test strips act properly and ensures the analyzer provides accurate results.

Describe the steps to perform quality control testing Identify how to recall stored results List the steps to prepare the control solution Upon successful completion of this course, you will be able to: En la preparación de la muestra, el plasma rico en plaquetas (o PRP) y el plasma pobre en plaquetas (o PPP) se colocan en distintas gradillas. Las gradillas de muestras se deben definir como gradilla para PRP y gradilla para PPP. Hay seis colores disponibles para las distintas plantillas de gradillas de muestras. Una vez que las muestras se hayan recogido y preparado correctamente para la realización de las pruebas y cuando los reactivos ya estén preparados, podrá poner en marcha el procesamiento de las muestras en el analizador. La mayor automatización de los pasos del procesamiento de muestras no solo libera al técnico para realizar otras tareas esenciales, sino que también aumenta la estandarización del ensayo. Congratulations.  You have completed the CLINITEK Advantus® Urine Chemistry Analyzer Quality Control Online Training course.  Listed below are the key points that have been presented.  Take time to review the material before you proceed to the final quiz. List the steps to prepare the controls for testing    Run quality controls under the following conditions: Determined by your facility's operating procedures at regular intervals Using a new shipment of urine test strips Using a new lot number of urine test strips Opening a new bottle of urine test strips Test results are in doubt Training new operators     Steps to prepare the controls for testing Add 12 mL distilled or DI H20 into an appropriately labeled tube Remove a Chek-Stix® control strip Place the control test strip into the appropriate tube Cap the tube and invert gently for 2 minutes Allow the tube to stand for 30 minutes Invert the tube 1 more time Uncap the tube and discard the control strip per laboratory procedure Store at temperatures under 30°C and stable for 8 hours after preparation Repeat the steps for the other control Describe the steps to perform quality control testing    The steps for testing the control specimens on the CLINITEK Advantus® Analyzer include: Select Menu from the Ready/Run screen Select QC Enter Lot information Enter Expiration date Completely immerse all reagent pads into the control solution Immediately remove the urine strip While removing the strip, run the edge against the side of the container Place the urine strip onto the strip loading station Repeat for each additional control Identify how to recall stored results    The steps to recall stored QC results include: Select Menu from the Ready/Run screen Select Memory Select All QC Results Select Next to continue.   En un panorama habitual, los laboratorios realizarán pruebas estándar de la funcionalidad de las plaquetas en los pacientes, pero en situaciones donde estas pruebas producen resultados no concluyentes o donde se necesita más información, los laboratorios realizarán pruebas más complejas, como la prueba de agregación plaquetaria.   Aquí se muestra una lista de varios escenarios clínicos que pueden fundamentar la necesidad de realizar estudios de agregación plaquetaria, como pacientes con posibles trastornos hemorrágicos específicos, pacientes bajo tratamiento con antiagregantes plaquetarios o pacientes diagnosticados o con riesgo de una enfermedad trombótica. After preparing the appropriate positive and negative controls, it is time to test the controls on the CLINITEK Advantus® Analyzer. The steps for testing the control solution include: Select Menu from the Ready/Run screen Select QC Enter Lot information Enter Expiration date Select Enter when ready to test the control Completely immerse all reagent pads into the control solution Immediately remove the urine strip While removing the strip, run the edge against the side of the container Place the urine strip onto the supports of the strip loading station with the reagent pads facing up. Ensure that the end of the strip is against the back wall of the platform and that it is not touching the bottom of the strip loading station.  Repeat for each additional control Caution: Do not blot the edge of the strip. This could affect results. Performing Quality Control Test Learn about performing quality control tests. Testing Control Specimens Select Menu on the Ready/Run screen Select QC Enter ID number Select QC0001 to reset the number Select A-Z to enter characters Select Enter to return to the numeric keypad QC Lot ID can be entered from a keyboard or scan it from a barcoded label Enter the expiration date Enter the year in the format YYYY Enter the month in the format MM The date can be entered from a keyboard or scan it form a barcoded label Select Enter to save the expiration date Select Enter Completely immerse all reagent pads into the quality control solution Immediately remove the urine strip While removing the strip, run the edge against the side of the container Caution: Do not blot the edge of the strip. This could affect results Place the urine strip onto the supports of the strip loading station, with reagent pads facing up Repeat for each additional control The CLINITEK Advantus® Urine Chemistry Analyzer can store up to 200 quality control records. The steps to recall stored QC results include: Select Menu from the Ready/Run screen Select Memory Select All QC Results   Pour l’évaluation de la qualité de l’échantillon, les deux indicateurs suivants ont été ajoutés pour la méthode d’agrégation plaquettaire : Courbe d’agrégation douteuse : la valeur à blanc mesurée du plasma pauvre en plaquettes (ou PPP) est   improbable ou ne correspond pas au rapport attendu au plasma riche en plaquettes (ou PRP) pour l’une des raisons suivantes : • une absorbance élevée pour l’échantillon PPP due à des substances d’interférence (hémoglobine, bilirubine ou lipides) ; • une absorbance élevée due au chargement d’un échantillon PRP au lieu d’un échantillon PPP ; • ou une absorbance étonnamment faible pour l’échantillon PRP due à une numération plaquettaire très faible. Valeur à blanc douteuse : les valeurs à blanc mesurées du PPP et du PRP sont improbables, par exemple en raison d’un mélange de l’échantillon PPP et de l’échantillon PRP. Welcome to the CLINITEK Advantus® Urine Chemistry Analyzer Quality Control online training course. This online training course will cover: Preparing the control solution Performing a quality control test Recalling stored data Select Next to continue. Após a conclusão com êxito deste curso, será capaz de: Descrever o princípio utilizado no teste de agregação de plaquetas (pause) Listar os estados clínicos da doença que justificam a necessidade de testes de agregação de plaquetas (pause) Discutir a importância da recolha e preparação das amostras no processo de teste (pause) Identificar os vários reagentes (ou agonistas) utilizados pelos analisadores Atellica COAG 360 durante os testes de agregação de plaquetas (pause) e Descrever as etapas do processamento das amostras para os testes de agregação de plaquetas. Run Quality Controls under the following conditions: Determined by your facility's operating procedures at regular intervals Using a new shipment of urine test strips Using a new lot number of urine test strips Opening a new bottle of urine test strips Test results are in doubt Training new operators Preparing Quality Control Learn about preparing quality control for testing. Preparing Quality Control Follow the manufacturer's instructions when preparing the controls. Here are the instructions for Siemens' Chek-Stix control strips for urinalysis: Add 12 mL distilled or DI H20 into an appropriately labeled tube Remove a Chek-Stix® control strip Place the control test strip into the appropriate tube Cap the tube and invert gently for 2 minutes Allow the tube to stand for 30 minutes Invert the tube 1 more time Uncap the tube and discard the control strip per laboratory procedure Store at temperatures under 30°C and stable for 8 hours after preparation Repeat the steps for the other control Note: Do not dip more than 12 Siemens reagent strips into a single tube of control solution, as expected values may change.

  • clini
  • advantis
  • qc
  • control solution
  • recall stored results
  • clinical laboratory training