CLINITEK Atlas® Automated Urine Chemistry Analyzer Maintenance Online Training
Perform the Daily Maintenance Tasks. Perform the Periodic Maintenance Tasks. Describe the As Needed Maintenance Tasks. This clinical laboratory training qualifies for continuing education units (CEU).
Use the full and split icon to show History and Current Events Simultaneously. Welcome to the CLINITEK Atlas® Automated Urine Chemistry Analyzer Maintenance Online Training course. This course will introduce you to the routine and as needed maintenance procedures that are performed on the system. Performing these maintenance procedures routinely and properly helps to keep your system running efficiently. Select Next to continue. Identify the As Needed Maintenance Tasks Identify the Daily Maintenance Tasks List the Periodic Maintenance Tasks Upon successful completion of this course you will be able to: Select Next to continue. Optional Aldrete Score An Aldrete Score window will appear with every new NIBP if configured to do so within the Events Configuration Window. After the initial Aldrete Score, the information from the previous score will populate concurrently. If the patient status has not changed, simply hit OK –otherwise, change the value before selecting OK. Congratulations. You have completed the CLINITEK Atlas Automated Urine Chemistry Analyzer Maintenance Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Identify the Daily Maintenance Tasks Clean the SG Well by placing a tube of bleach into the STAT holder and selecting Clean SG Well from the Main Menu. Check the supply of reagent strips by reviewing the Ready for Testing screen. List the Periodic Maintenance Tasks Change the reagent roll when the supply is low or every 14 days. Clean the readhead sockets every four months or every 100 Reagent Paks using the round end of the cleaning brush. Check the pipette for leakage using Analyzer Diagnostics. Identify the As Needed Maintenance Tasks Replace the lamp assembly Turn instrument off and remove cover plate Disconnect lamp wire connector and push lamp lever Remove lamp and install replacement Push the lamp lever and reconnect the lamp wire Replace lamp cover plate, close the doors and turn the instrument on Replace the Pipette Assembly Enter Analyzer Diagnostics Select Replace Pipette and follow prompt Remove the tubing from the syringe valve and disconnect the small plug Remove two thumbscrews on square block and lift pipette Install new pipette and tighten thumbscrews Connect the small plug, insert tubing into clip on back wall, screw fitting into the valve Replace the Syringe Enter Analyzer Diagnostics Select Replace Syringe and follow prompt Unscrew syringe Loosen and remove screw that secures the plunger Remove syringe from the system and prepare new syringe Loosely replace the plunger screw Pull up on the syringe and rotate counterclockwise Tighten the plunger screw Lubricate the Lead Screw Turn the instrument off Clean the lead screw Apply the Lead Screw Lubricant down the length of the lead screw Turn the instrument on Select Next to continue. This is an example of the touchscreen overview with Artisversions VB software. Daily maintenance procedures: Clean the SG Well Check supply of reagent strips After performing the daily maintenance procedures, update the Maintenance Log to document that the maintenance was completed. Clean the SG Well Learn about cleaning the SG Well. Checklist TitleChecklist TypeChecklist ContentPrepare Tube of BleachHTML Pour at least two milliliters of household bleach (5.25% sodium hypochlorite) into a sample tube. Bleach stronger than 5.25% sodium hypochlorite damages the SG Well and should be diluted with water before use. Select each checkbox to learn more about cleaning the SG Well. Load Tube in STAT HolderHTML Load the tube of bleach into the STAT holder. Select Clean SG WellHTML Select Clean SG Well from the Main Menu. Move Tube Into PositionHTML Push the STAT holder forward. Select BeginHTML Select Begin. When complete, select the X in the upper-right corner to close the window and continue. Check Supply of Reagent Strips Learn about checking the supply of reagent strips. The Ready for Testing screen displays the status of the reagent strips with the following information: Number of strips remaining Number of days remaining When complete, select the X in the upper-right corner to close the window and continue. You can also enter multiple oxygen saturation results and choose the one you wish to include or remove. This will provide you with an average oxygen saturation for that site. Periodic maintenance procedures: Loading a new reagent roll Cleaning the readhead sockets Checking the pipette for leakage After performing the periodic maintenance procedures, update the Maintenance Log to document that the maintenance was completed. Note: After cleaning the readhead sockets, you must recalibrate the instrument and run controls. Loading a New Reagent Roll Learn about loading a new reagent roll. Checklist TitleChecklist TypeChecklist ContentVerify Reagent StatusHTML Check the Ready for Testing screen for reagent information. The reagent roll should be changed every 14 days or when reagent strip count is empty. Select each checkbox to learn more about loading a new reagent roll. Prepare CalibratorsHTML Remove the Calibration Kit from the refrigerator to allow the Calibration Solutions to come to room temperature. Load the Reagent RollHTML If the media does not automatically start, select the play arrow to begin. Check Rinse SolutionHTML Check the volume of the Rinse Solution remaining in the container and ensure that at least one liter is available. To prepare Rinse Solution: Empty any solution from the rinse bottle. Clean this bottle thoroughly or use a fresh one. Fill it with 1000 mL of distilled or deionized water. Add 2mL of CLINITEK Atlas Rinse Additive and swirl gently to mix. Replace the rinse bottle. Perform CalibrationHTML Calibration is required if more than 24 hours have elapsed since the last calibration or if the lot number of the reagent roll just loaded is different from the previous reagent. Refer to the CLINITEK Atlas Analyzer operating manual or the CLINITEK Atlas Automated Urine Chemistry Analyzer Calibration Online Training course for instructions. Note: Calibration is optional if the last calibration was performed within the previous 24 hours and the lot number of the reagent roll has not changed. In this case, only the SG Well needs to be cleaned. Clean the SG WellHTML Cleaning the SG Well is required after replacing the reagent roll. Load a tube of bleach in the STAT holder and select Clean SG. When complete, select the X in the upper-right corner to close the window and continue. Cleaning the Readhead Sockets Learn about cleaning the Readhead Sockets. If the media does not automatically start, select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue. Checking the Pipette for Leakage Learn about checking the pipette for leakage. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90007035/sim_ATL_ReplacePipette_800x600_9/sim_ATL_ReplacePipette_800x600_9.swfHTML5 File:/content/generator/Course_90007035/sim_ATL_ReplacePipette_800x600_9/index.htmlPDF File: By right clicking on the site label, you can access different activities for the waveform. Here you can change the site label or set up a pullback. It also allows access to the properties menu. Use your mouse to rollover the highlighted icons to view more. As needed maintenance procedures: Replacing the lamp assembly Replacing the pipette assembly Replacing the syringe Lubricating the lead screw After performing the as needed maintenance procedures, update the Maintenance Log to document that the maintenance was completed. Note: When any of these procedures are performed, the instrument needs to be recalibrated and controls processed. Replacing the Lamp Assembly Learn about replacing the lamp assembly. If the media does not automatically start, select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue. Replacing the Pipette Assembly Learn about replacing the pipette assembly. If the media does not automatically start, select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue. Replacing the Syringe Learn about replacing the syringe. If the media does not automatically start, select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue. Lubricate the Lead Screw Learn about lubricating the lead screw. Checklist TitleChecklist TypeChecklist ContentTurn the Instrument OffHTML The syringe should be lubricated if the syringe mechanism begins making a squeaking or grinding sound. Be sure the instrument is in the Standby Mode so the syringe is in its uppermost position and then turn the instrument off. Select each checkbox to learn more about lubricating the lead screw. Open the Instrument DoorsHTML Open the instrument doors. Obtain Lead Screw LubricantHTML Obtain the Lead Screw Lubricant, which is included in the Supply Kit. Clean Lead ScrewHTML Clean the lead screw if necessary. Apply Lubricant to Lead ScrewHTML Draw a thin line of lubricant down the length of the lead screw. Use the lubricant very sparingly. Close the Instrument DoorsHTML Close the instrument doors. Turn the Instrument OnHTML Turn the instrument on. Press 5 on Main MenuHTML After the instrument has completed its initialization cycle, enter the Main Menu and press 5 to prime the pump. This will distribute the lubricant over the full length of the lead screw. When complete, select the X in the upper-right corner to close the window and continue.
- clini
- clean sg well
- check reagent strips
- load reagent roll
- clean readhead sockets
- clean read head sockets
- check pipette
- replace pipette
- repalce lamp
- replace syringe
- lubricate lead screw
- clinical laboratory training