CLINITEK Novus® Automated Urine Chemistry Analyzer Maintenance Online Training
Describe the daily maintenance tasks. Identify the periodic maintenance tasks. Describe the as needed maintenance tasks.
Welcome to the CLINITEK Novus® Automated Urine Chemistry Analyzer Maintenance Online Training course. This course will introduce you to the routine and as needed maintenance procedures that are performed on the system. Performing these maintenance procedures routinely and properly helps to keep your instrument running efficiently. Select Next to continue. Describe the as needed maintenance tasks Describe the daily maintenance tasks Identify the periodic maintenance tasks Upon successful completion of this course, you will be able to: Select Next to continue. Cuando se encuentre con algún un problema mientras utiliza ADVIA 2120i, puede encontrar ayuda en la Guía del operador en línea. Hay una sección entera dedicada a solucionar problemas del analizador. Hay subsecciones dentro tales como: Alineaciones y ajustes Procedimientos de limpieza Reparación y sustitución Sugerencias para la solución de problemas Alarmas morfológicas Alarmas de muestra / sistema Las alarmas de muestra / sistema y las alarmas morfológicas pueden ayudarle a determinar la causa de un error mediante la lista de causas relacionadas con el sistema y causas relacionadas con la muestra. Una vez determinada la causa, Alineaciones y ajustes, Procedimientos de limpieza y Reparación y sustitución ayudarán a corregir el problema. Congratulations. You have completed the CLINITEK Novus® Automated Urine Chemistry Analyzer Maintenance Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Describe the daily maintenance tasks Cleaning the rack handler: use a germicidal wipe to ensure smooth movement of racks and avoid bacterial growth Cleaning the SG well Pour 2mL of household bleach (5.25%sodium hypochlorite) into a sample tube Load the tube of bleach From the Home screen, select System > SG Well > Start Identify periodic maintenance tasks Priming the pump: perform after refilling the rinse bottle, if air bubbles appear in rinse solution line or when an error indicates that you should prime the pump Cleaning the card platform: clean with 70% isopropyl alcohol or 10% bleach when a large amount of urine spills onto the area Cleaning the card grippers: clean with 70% isopropyl alcohol when debris is present Cleaning the pad sensor: clean with compressed air to remove card dust in the cassette compartment Describe the as needed maintenance tasks Replacing the pipette From the Home screen, select System > Diagnostics > Replace or Adjust > Replace Pipette Follow the on screen instructions to remove the pipette Follow the on screen instructions to replace the pipette Adjust the pipette depth Verify the pipette replacement Replacing the SG sensor From the Home screen, select System > Diagnostics > Replace or Adjust > Replace SG Sensor Follow the on screen instructions to remove the SG sensor Follow the on screen instructions to replace the SG sensor Wait 1 hour for the system to hydrate the SG sensor Calibrate the system Select Next to continue. Daily maintenance tasks: Cleaning the rack handler Cleaning the SG well Cleaning the Rack Handler Learn about cleaning the rack handler. Cleaning the rack handler on a daily basis helps to: Ensure that the system operates smoothly Ensure smooth movement of racks Avoid bacterial growth To clean the rack handler, use a germicidal wipe on the loading and unloading areas of the system. When complete, select the X in the upper-right corner to close the window and continue. Cleaning the SG Well Learn about cleaning the SG well. Checklist TitleChecklist TypeChecklist ContentPrepare Tube of BleachHTML Pour at least 2mL of household bleach (5.25% sodium hypochlorite) into a sample tube labeled Bleach. Select each checkbox to learn more about cleaning the SG well. Load Tube of BleachHTML If you are using the CLINITEK® AUWi PRO™ system, place the tube of bleach in the STAT holder and push it forward. If you are using a stand alone CLINITEK Novus® system, place the tube of bleach in the first test position in a rack. Place the rack in the loading area of the rack handler. Select SystemHTML Select System. Select Clean SG WellHTML Select Clean SG Well. Select StartHTML Select Start. The cleaning cycle takes about 3 minutes to complete. When complete, select the X in the upper-right corner to close the window and continue. El sistema está equipado con escopia, Roadmap, protocolos de adquisición y syngo DynaCT habitualmente con alternativas para uso con dosis bajas. Se ha incorporado un contador de escopia en el sistema, que está configurado según los requisitos legales locales. Se activará una alarma acústica cuando haya transcurrido el tiempo configurado. Para lograr una mayor protección contra la radiación dispersa del personal operador, se pueden instalar dispositivos de protección contra la radiación alrededor del sistema ARTIS en forma de protección contra la radiación en la parte superior e inferior del cuerpo. Periodic maintenance tasks: Priming the pump Cleaning the card platform Cleaning the card grippers Cleaning the pad sensor Select Next to continue. Enhorabuena. Ha finalizado el curso ARTIS pheno: Formación en línea sobre conceptos básicos y seguridad del sistema. A continuación se enumeran los puntos clave que se han presentado. Tómese su tiempo para revisar el material antes de responder el cuestionario final. Priming the pump primes the syringe pump with rinse solution. This task should be performed: When you refill the rinse bottle If air bubbles appear in the rinse solution line When an error message indicates that you should prime the pump To prime the pump: Select System from the home screen Select Prime Pump Select Next to continue. The card platform should be cleaned: When a large amount of urine or other liquid spills onto the area With 70% isopropyl alcohol or 10% bleach Cleaning the Card Platform Learn about cleaning the card platform. Checklist TitleChecklist TypeChecklist ContentEject CardsSimulationInstructions:If the media do not automatically start, select the play arrow to begin. Select each checkbox to learn more about cleaning the card platform. Flash File:/content/generator/Course_90010770/sim_CN_EjectCards_HMTL5_800x480_9/sim_CN_EjectCards_HMTL5_800x480_9.swfHTML5 File:/content/generator/Course_90010770/sim_CN_EjectCards_HMTL5_800x480_9/index.htmlPDF File:Open the System CoverHTML Open the system cover by pulling on the cover handle. Remove the PlatformHTML Pull up on the left side of the platform and slide it to the left. Clean the PlatformHTML Clean the platform with 70% isopropyl alcohol or 10% bleach. Insert the PlatformHTML To insert the platform into the instrument: Slide the mounting tab on the right side of the platform into the mounting slot beneath the card gate Push down on the left side of the platform to snap the platform holes into the alignment pins Close the System CoverHTML Use the cover handle to close the system cover. Select Exit to return to the Home screen. When complete, select the X in the upper-right corner to close the window and continue. Welcome to the ACUSON Juniper™ Ultrasound System Contrast-Enhanced Echocardiography for Left Ventricular Opacification (LVO) course. The Juniper ultrasound system has an intuitive touch-screen layout that is streamlined to include only the functions necessary to confidently perform LVO exams. When clinically indicated, contrast-enhanced echocardiograms for Left Ventricular Opacification (LVO) can facilitate wall motion assessment and provide diagnostic confidence. Additionally, in this course you will be introduced to a high-level general overview of the physical properties of the microbubble used in contrast-enhancement for LVO. There are several interactions to navigate in this course. Below is a helpful explanation on some of the automated interactions that you may use in this PEPconnect course. The card grippers should be cleaned: When debris is present With 70% isopropyl alcohol Cleaning the Card Grippers Learn about cleaning the card grippers. Checklist TitleChecklist TypeChecklist ContentOpen the System CoverHTML Open the system cover by pulling on the cover handle. Select each checkbox to learn more about cleaning the card grippers. Check the Card GrippersHTML Check the 2 card grippers on the right side of the card platform for debris. Clean the Card GrippersHTML Clean the card grippers with 70% isopropyl alcohol. Close the System CoverHTML Use the cover handle to close the system cover. When complete, select the X in the upper-right corner to close the window and continue. The ACUSON Juniper ultrasound system has an intuitive touch screen layout and streamlined workflow for LVO. In this section, you will review instrumentation that impacts the microbubble. Additionally, we will review the instrumentation on the Juniper ultrasound system that impacts image quality for contrast-enhanced echocardiograms for LVO. Clean the pad sensor: To remove card dust in the cassette compartment if a card jam error occurs or once a year With compressed air Cleaning the Pad Sensor Learn about cleaning the pad sensor. Checklist TitleChecklist TypeChecklist ContentSelect SystemHTML Select System. Select each checkbox to learn more about cleaning the pad sensor. Select Load & Unload CassetteHTML Select Load & Unload Cassette. Open the System CoverHTML Open the system cover by pulling on the cover handle. Remove the CassetteHTML Turn the lock counterclockwise and open the door. Remove the cassette from the compartment. Note: Do not leave the cassette compartment moisture gate open for longer than 10 minutes when a cassette is in the compartment. Spray Compressed AirHTML Spray the pad senor with compressed air. Replace the CassetteHTML Return the cassette to the compartment. Close and lock the door. Close the System CoverHTML Close the system cover. When complete, select the X in the upper-right corner to close the window and continue. Si se aplica el tipo de visualización MPR/MPR, las dos series seleccionadas se fusionan. La fusión de imágenes puede ayudarlo a evaluar más detenidamente estructuras sospechosas o a realizar mediciones específicas. Para fusionar imágenes, siga estos pasos en un formato de pila: 1. Seleccione los dos segmentos que muestren las imágenes que desea fusionar usando Ctrl y el botón izquierdo del ratón. 2. Seleccione el tipo de visualización MPR/MPR en el menú de la esquina inferior izquierda. Las imágenes se visualizan en una vista fusionada automáticamente en la que se alinea el centro de los volúmenes de ambas series. 3. Opcionalmente, utilice la opción Alineamiento visual del menú de la esquina superior izquierda para adaptar manualmente el alineamiento. 4. Guarde los ajustes realizados en la "barra de herramientas de registro" que se muestra automáticamente en la parte inferior del segmento o elija otro algoritmo de registro. En caso de que solo se muestre uno de los volúmenes en el formato, haga lo siguiente para fusionar el segundo volumen: solo tiene que seleccionar la serie que vaya a fusionar en el panel Serie haciendo clic con el botón derecho del ratón, mantener pulsado el botón derecho del ratón y arrastrarla hasta el segmento que muestra la imagen con la que desea fusionarla. Suelte el botón derecho del ratón y seleccione Fusionar MPR/MPR en el menú contextual. As needed maintenance tasks: Replacing the pipette Replacing the SG sensor Replacing the Pipette Learn about replacing the pipette. Checklist TitleChecklist TypeChecklist ContentAccess DiagnosticsSimulationInstructions:If the media does not automatically start, select the play arrow to begin. Select each checkbox to learn more about replacing the pipette. Flash File:/content/generator/Course_90010770/sim_CN_DiagReplacePip_HTML5_800x480_9/sim_CN_DiagReplacePip_HTML5_800x480_9.swfHTML5 File:/content/generator/Course_90010770/sim_CN_DiagReplacePip_HTML5_800x480_9/index.htmlPDF File:Remove the PipetteHTML Select the play arrow to begin. Install the PipetteHTML Select the play arrow to begin. Adjust the Pipette DepthSimulationInstructions:If the media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90010770/sim_CN_AdjustPipette_HTML5_800x480_9/sim_CN_AdjustPipette_HTML5_800x480_9.swfHTML5 File:/content/generator/Course_90010770/sim_CN_AdjustPipette_HTML5_800x480_9/index.htmlPDF File:Verify the Pipette ReplacementSimulationInstructions:If the media does not automatically start, select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue. Flash File:/content/generator/Course_90010770/sim_CN_VerifyPipetteRepl_HTML5_800x480_9/sim_CN_VerifyPipetteRepl_HTML5_800x480_9.swfHTML5 File:/content/generator/Course_90010770/sim_CN_VerifyPipetteRepl_HTML5_800x480_9/index.htmlPDF File: Replacing the SG Sensor Learn about replacing the SG sensor. Checklist TitleChecklist TypeChecklist ContentAccess DiagnosticsSimulationInstructions:If the media does not automatically start, select the play arrow to begin. Select each checkbox to learn more about replacing the SG sensor.Flash File:/content/generator/Course_90010770/sim_CN_DiagReplaceSGSensor_800x480_9/sim_CN_DiagReplaceSGSensor_800x480_9.swfHTML5 File:/content/generator/Course_90010770/sim_CN_DiagReplaceSGSensor_800x480_9/index.htmlPDF File:Remove the SG SensorHTML Select the play arrow to begin. Install the SG SensorHTML Select the play arrow to begin. When complete, select the X in the upper-right corner to close the window and continue.
- urine
- maint
- maintenance
- novis
- novus