CLINITEK Status®+ System Urinalysis Quality Control Strip Test Online Training

Perform QC testing to ensure test strips react properly and the analyzer reads accurately.

Identify how to delete records from instrument memory (Option must be enabled on analyzer; Operator must have required security access.) Identify how to recall stored results Identify products approved for use on the CLINITEK Status®+ Analyzer Identify the steps to set up and run QC test strips After successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have completed the CLINITEK Status®+ System Urinalysis Quality Control  Strip Test Online Training course. In this course, you have learned how to: Identify the steps to set up and run QC test strips Performing QC helps ensure that urinalysis test strips are reacting properly and that the instrument accurately reads them. QC testing also can help detect user technique errors. Run QC as determined by your facility's operating procedures at regular intervals and whenever you are when using a new shipment of reagents, a new lot number of reagent, opening a new bottle of reagents, test results are in doubt, or training new operators. The CLINITEK Status®+ Analyzer does not discriminate between a QC sample and a patient sample.  You will be required to manually run, review and log QC test results. The CLINTEK Status® Connect System supports new QC management capabilities.  The analyzer now can be programmed to accept quality control tests and can analyze automatically if a QC test passes based on pre-defined criteria.  The system maintains a separate database of results for QC and patient samples. The system supports Siemens or other manufacturers control materials. If using Siemens’ Chek-Stix® Urinalysis positive and negative controls, these can be prepared to verify performance of the specific gravity, pH, protein, glucose, ketones, bilirubin, blood, nitrite, urobilinogen, and leukocyte (white blood cells) tests. Note:  Siemens Chek-Stix controls require preparation and are not recommend for use in CLIA-waived settings where the use of commercially available liquid-controls is preferred. Identify products approved for use on the CLINITEK Status®+ Analyzer The CLINITEK Status®+ Analyzer uses only Siemens Healthcare Diagnostics products, which include: Siemens Healthcare Diagnostics test strips: chemically impregnated reagent strips that allow technicians to perform a single test and obtain semi-quantitative results for a number of different test parameters Identify how to recall stored results The CLINITEK Status® platform offers expanded on-board memory storage for patient results that are recalled easily for improved data management. The CLINITEK Status® Connect system also stores quality control results. The CLINITEK Status® Connect Platform stores up to 950 patient test results in the onboard memory. When the limit of 950 has been reached, the oldest test will be deleted from the analyzer. Deleted information cannot be retrieved from the analyzer. The CLINITEK Status® Connect System can store 200 QC results in the onboard memory.  As there is no QC functionality on the CLINITEK Status®+ Analyzer, QC results must be tracked manually. Identify how to delete records from instrument memory Patient and QC records stored on the analyzer can be deleted permanently from instrument memory. Individual records cannot be deleted. Before deleting records, save the database to an external source. Data stored on an LIS will not be deleted.  This option must be enabled on the analyzer, and the operator must have the required security access. Select Next to continue. L'analyseur Clinitek Status ® + est un instrument portatif idéal pour les cabinets médicaux, les cliniques et les lieux de soin. L'analyseur lit les bandelettes urinaires Siemens Healthcare Diagnostics pour aider les médecins à vérifier le métabolisme glucidique, les fonctions rénales et hépatiques, l'équilibre acide / base et d'autres états métaboliques, ainsi qu'à détecter une infection urinaire et d'autres troubles. Le système utilise également des cassettes de dosage immunologiques Clinitest® pour effectuer des tests de grossesse hCG qualitatif. Lorsque l'analyseur est connecté au connecteur CLINITEK Status®, il forme le système CLINITEK Status® Connect. Le connecteur offre une connectivité flexible pour améliorer l'intégration des données à un SIL et / ou à des logiciels de gestion de données, la saisie de codes-barres, les fonctions avancées de gestion des opérateurs et du CQ. Des détails supplémentaires concernant ce système seront abordés dans des modules séparés. Run QC when: Determined by your facility's operating procedures at regular intervals Using a new shipment of urine test strips Using a new lot number of urine test strips Opening a new bottle of urine test strips Test results are in doubt Training new operators QC Tests Learn about running QC tests on the CLINITEK Status Connect system. Tab TitleTextCLINITEK Status®+ Analyzer Quality control solutions can be tested. However, the CLINITEK Status+ Analyzer does not discriminate between a QC sample and a patient sample.  You will be required to manually run, review, and log QC test results and assess if QC results have passed or failed. Clean the test table insert each time after performing QC. CLINITEK Status® Connect The CLINTEK Status Connect System supports new QC management capabilities. The analyzer now can be programmed to identify and track quality control tests separately from patient results and can assess automatically if a QC test passes based on pre-defined criteria. The system maintains a separate database of results for QC and patient samples. The system supports Siemens or other manufacturers control materials. If using Siemens’ Chek-Stix® Urinalysis positive and negative controls, these can be prepared to verify performance of the specific gravity, pH, protein, glucose, ketones, bilirubin, blood, nitrite, urobilinogen, and leukocyte (white blood cells) tests. Clean the test table insert each time after performing QC. Note: Siemens Chek-Stix controls require preparation and are not recommend for use in CLIA-waived settings where the use of commercially available liquid-controls is preferred. When complete, select the X in the upper-right corner to close the window and continue. Running QC Tests Learn how to run QC tests on the CLINITEK Status® Connect System.   Select the play arrow to begin the video. When complete, select the X in the upper-right corner to close the window and continue. The CLINITEK Status®+ Analyzer uses Siemens Healthcare Diagnostics test strips to perform a single test and obtain semi-quantitative results for a number of different test parameters, such as: Albumin Albumin-to-Creatinine Ratio Bilirubin Blood Creatinine Glucose Ketones Leukocyte (white blood cells) Nitrites Protein pH Protein-to-Creatinine Ratio Specific gravity Urobilinogen Note: The analyzer supports only those test strips validated for use on the system and will not report results for non-validated Siemens test strips. Siemens Healthcare Diagnostics Products Learn more about products approved for use. Products approved for use on the CLINITEK Status®+ Analyzer are shown below. Note: Not all test strips are available in all markets. Urinalysis Test Strips Kidney Disease Portfolio Control Reagents Multistix® 10 SG Multistix® 8 SG Multistix® 7 Multistix® 5 Multistix® SG Multistix® GP N-Multistix® SG N-Multistix® SG L Uro-Hemacombistix® SG L Uro-Hemacombistix® Hemacombistix® Uristix® Uristix® 4 Labstix® SG N-Neostix® Uro-Uristix® Combistix® SG CLINITEK® Microalbumin 2 strip CLINITEK® Microalbumin 9 Multistix® PRO 10SL   Chek-Stix® Urinalysis Control Strips (Positive)  Chek-Stix® Combo Pak (Positive/Negative)  When complete, select the X in the upper-right corner to close the window and continue. When used as a standalone or in conjunction with the Connector Platform, the CLINITEK Status®+ Analyzer stores up to 950 patient test results in the on-board memory. When the limit of 950 has been reached, the oldest test will be deleted from the analyzer. Deleted information cannot be retrieved from the analyzer. Note: The CLINITEK Status® Connect System can store 200 QC results in the on board memory.  As there is no QC functionality on the CLINITEK Status®+ Analyzer, QC results must be tracked manually.   Recall Results Learn how to recall stored results. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90006159/simCSPlusRecallResultsKC2___9/simCSPlusRecallResultsKC2___9.swfHTML5 File:/content/generator/Course_90006159/simCSPlusRecallResultsKC2___9/index.htmlPDF File: Patient and QC records stored on the analyzer can be deleted permanently from instrument memory.  Prior to deleting records, save the database to an external source.  Records cannot be deleted on an individual basis. Data stored on an LIS will not be deleted. Reminder: The CLINITEK Status®+ Analyzer stores QC records as patient tests. Note: This action can be performed only if the function is enabled on the analyzer and authorization is permitted by your facility.   Deleting Stored Records Learn how to delete stored records. Checklist TitleChecklist TypeChecklist ContentSelect ReadyHTML Select each check box to learn more about deleting records. On the Select Ready screen, click the Recall Results Button.  Recall OptionsHTML   On the Recall Options screen, use the down arrow to highlight the Delete Records option then click Select. This selection will be greyed out if the option is not enabled on the analyzer.    Delete RecordsHTML On the Delete Records screen, select Yes to delete all records and return to the Select Ready screen or select NO to return to the Recall Options screen. When complete, select the X in the upper-right corner to close the window and continue.

  • clini
  • connect
  • +
  • plus
  • recall stored results
  • delete records
  • clinical laboratory training