PEPconnect

Configuring Quality Guard (Biograph mCT VG70)

Quality Guard offers an automatic and phantomless QC option. This step by step procedure will assist the user in configuring the Quality Guard option on the Biograph mCT (VG70

Configuring Quality Guard Biograph mCT (VG70) Description: Quality Guard offers an automatic and phantomless QC option. This step by step procedure will assist the user in configuring the Quality Guard option on the Biograph mCT (VG70). 1. From the syngo Acquisition Workplace (ICS), select Configuration from the Options menu and select PET QC Configuration. PET QC Configuration 2. Choose the Automatic QC tab. PET QC Configuration Phantom Automatic QC QualityGuard Auto QC with Phantom QC Schedule Day Mon Tue Wed Thu Fri Sat Sun Auto QC Start 13:30:30 Auto QC End 21:30:30 OK Apply Cancel Help 3. Choose the day(s) of the week you would like Quality Guard to be performed. 4. Set the start time that you would Quality Guard to run. 5. Click OK and Apply SIEMENS siemens.com/healthineers Healthineers Configuring Quality Guard Effective Date: 09/03/2018 | Quality HOOD05162002937462 6. Ensure the PHS and any other objects are clear of the gantry tunnel prior to the start time. 7. Once Quality Guard completes, a report will appear on the screen. QualityGuard Report Scan Date: October 11, 2017, 17:00:30 Input for Computation: Last Partial Setup October 11, 2017, 15:12:23 Last Partial Setup Completion State setup succeeded Last Full Setup October 11, 2017, 15:12:23 Last Full Setup Completion State setup succeeded Last Time Alignment October 11, 2017, 15:12:23 Last Time Alignment Completion State time alignment succeeded Days Until Full Setup 75 ICS Name SOM7SIM70 SW Version PETSYNGO_VG70A 760.100.1710.1101 Gantry Type 1104 Results: QualityGuard Results Passed Fansum bitmap location HASiteData\DailyQC PETFansum QualityGuard 11102017 1700301 QualityGuard successfully completed. Necessary files from setup were not found Call Service Detailed QualityGuard Report: Item Upper Bound Lower Bound Value Decision Max Temperature Shift 1.00 [Degrees] 0.00 [Degrees] 0.21 [Degrees] Passed Max Location Shift 4.00 [Pixels] 0.00 [Pixels] 2.38 [Pixels] Passed Max Energy Shift 4.00 [Bins] 0.00 [Bins] 0.14 [Bins] Passed Min Energy Ratio 1.85 1.60 1.76 Passed Max Energy Ratio 1.85 1.60 1.68 Passed 8. If Quality Guard completes successfully, click the Ok button. If Quality Guard was unsuccessful, perform a manual Full Setup using the phantom source. PET Auto QC Result X PASS Days Until Next Full Setup 75 OK Siemens Healthineers Services Page 2 of 3 Configuring Quality Guard Effective Date: 09/03/2018 | Quality HOOD05162002937462 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018

  • Configuring Quality Guard (Biograph mCT VG70)