(D13) Dot Add-in Configurator Protocols_Editing Auto Timing
(D13) Dot Add-in Configurator Protocols_Editing Auto Timing
(D13) Dot Add-in Configurator Protocol – Editing Auto Timing Note: It is not necessary to define a condition to use the auto timing functionality. 1. Open > Exam Explorer > USER tree 2. Select > Region (Head) > Dot Engine > Program folder > DOT (Brain) 3. Select > Exam Strategy branch (e.g., t1_sag) 4. Select > Strategy (e.g., Standard) o Select Sequence > Right mouse > Select Properties 5. Select > Dot add-in tab > Edit configuration Exam Explorer - \USER\head Brain Dot Engine\program\t1_sag\Standard X Object Edit Tools Insert Help SIEMENS ............................................................................................................................................. 1 [1 f12d_sag 02:28 Generic Views USER head Brain Dot Engine 4 program Dot Brain mi localizer Om t1_sag ...... Standard + Resolution fod Speed focus Motion-insens ..... + 15 t2 + dark-fluid + mi epi_diffusion is t1_tra_pre + M contrast agent clinical libraries advanced applications programs library Protocol properties - Dot add-in - t1_f12d_sag X Standard Dot add-in Execution Auto load Copy References Dot add-in: Generic Views Edit Configuration. Reset Configuration OK Cance Help SIEMENS www.usa.siemens.com/healthcare 594 Effective Date: 09/06/2016 Page 1 of 3 6. Select > Setup button WUSER\head\Brain Dot Engine\program\t1_sag\Standard\t1_f12d_sag Details Dot views TA: 2:28 PM: REF PAT: Off Voxel size: 0.7x0.7x4.0 mm Rel. SNR: 1.00 : fl Slice group 1 FoV read 220 am Slices 25 FoV phase 100.0 Dist. factor 30 Slice thickness 4.0 Position |Isocenter TR 440.0 ms Orientation Sagittal Phase enc. dir. A >> P TE 2.46 ms AutoAlign Head > Basis Averages 1 Phase oversampling 30 Concatenations 1 % Filter | Prescan Normalize, E Coil elements |HE1-4 Routine Contrast Resolution |Geometry System Physio Inline Sequence OK Cancel Virtual Coils. Setup .. Help 7. Select > Auto Timing o Enable Auto Timing – Checkbox to view options SIEMENS Dot Add-In Configurator X t1_f12d_sag EE Copy Paste Enable Auto Timing Guidance Parameters Queue GSP Series Label Auto load Auto Coverage Auto Timing Show Preview Close SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 o Conditions o Assign specific Auto Timing parameters o Time Per Measure/Acquisition Time/Captured Cycle/Concatenations/TR/Time Per Concatenation/Time Per Measurement o Assign parameter limits o >/=/< o Assign breath-hold capability o Breath-hold capability o Other – Seconds dialog box allows entry in seconds(s) o Auto Timing will adapt the following parameters if the conditions are not met o Parameters – edit and set parameter rules o Determine if values increase; decrease or are equal o Up arrow/Down arrow/equal o Limit – edit and set limits for parameters o Increments – edit and set increments values for parameters o Goal o None/all/0 o Add/Delete parameters o Assign parameter hierarchy/priority SIEMENS Dot Add-In Configurator X t1_f12d_sag EE Copy Paste Enable Auto Timing Guidance Conditions 0 Acquisition Time Breath-hold capability Parameters Queue GSP Autotiming will adapt the following parameters if the conditions are not met Series Label Parameter Limit Increment Goal TR 100 ms 10.0 none Auto load 1 2 1 + Auto Coverage Auto Timing Show Preview Close SIEMENS www.usa.siemens.com/healthcare Page 3 of 3
- MAGNETOM Avanto
- MAGNETOM Aera
- MAGNETOM Skyra
- MAGNETOM Verio