(D13) Dot Add-in Configurator Protocols_Editing Guidance Images

(D13) Dot Add-in Configurator Protocols_Editing Guidance Images

(D13) Dot Add-in Configurator Protocol – Editing Guidance Images and Text Note: Edit guidance images in the Exam Explorer when scanning a patient to capture images displayed in the GSP segments in the Exam task card. 1. Open > Exam Explorer > USER tree 2. Select > Region (Head) > Dot Engine > Program folder > DOT (Brain) 3. Select > Exam Strategy branch (e.g., t1_sag) 4. Select > Strategy (e.g., Standard) o Select Sequence > Right mouse > Select Properties (or) Double left mouse click Exam Explorer - \USER\head Brain Dot Engine\program\t1_sag\Standard × Object Edit Tools Insert Help SIEMENS 1 11_f 12d_sag 02:28 Generic Views USER head Brain Dot Engine BY program Dot Brain m localizer mt1_sag Standard Resolution fod Speed focus Motion-insensi + 15 t2 + mi dark-fluid mi epi_diffusion +0 t1_tra_pre M contrast agent clinical libraries advanced applications programs library 5. Select > Dot add-in tab > Edit configuration Protocol properties - Dot add-in - t1_f12d_sag X Standard Dot add-in Execution Auto load Copy References Dot add-in: Generic Views Edit Configuration ... Reset Configuration OK Cancel Help SIEMENS www.usa.siemens.com/healthcare 596 Effective Date: 09/06/2016 Page 1 of 4 6. Select > Setup button WUSER\head\Brain Dot Engine\program\t1_sag\Standard\t1_f12d_sag Details Dot views A: 2:28 PM: REF PAT: Off Voxel size: 0.7x0.7x4.0 mm Rel. SNR: 1.00 : fl Slice group 1 + FoV read 220 mm Slices 25 FoV phase 100.0 % Dist. factor 30 Slice thickness 4.0 mm Position Isocenter TR 440.0 ms Orientation Sagitta ms Phase enc. dir. A >> P TE 2.46 AutoAlign Head > Basis Averages Phase oversampling 30 Concatenations % Filter | Prescan Normalize, E Coil elements |HE1-4 Routine Contrast Resolution Geometry System Physio Inline Sequence OK Cancel Virtual Coils .. Setup ... Help 7. Select > Guidance o Change Guidance Image Layout o Drop-down options: 1, 2, or 3 images and Text Only SIEMENS Dot Add-In Configurator x t1_f12d_sag EE Copy Paste Layout 3 images Text sag Guidance Slices are aligned by AutoAlign. Note that if you change slice positions manually, it might be impossible to reproduce these exact Parameters slice positions for subsequent protocols and follow-up examinations. Sagittal slices are aligned with the mid-sagittal plane as defined by the symmetry of the skull. (The Queue interhemispheric fissure is not used for the alignment of the mid-sagittal plane because it might shift due to mass effects.) GSP Tooltip ... Tooltip ... Tooltip. Series Label Auto load Auto Coverage Auto Timing Show Preview Close o Capture Images from Exam UI for Guidance Views o Select > Camera Icon SIEMENS Dot Add-In Configurator X t1_f12d_sag En Copy Paste Layout 3 images Text sag Guidance Slices are aligned by AutoAlign. Note that if you change slice positions manually, it might be impossible to reproduce these exact Parameters slice positions for subsequent protocols and follow-up examinations. Sagittal slices are aligned with the mid-sagittal plane as defined by the symmetry of the skull. (The Queue interhemispheric fissure is not used for the alignment of the mid-sagittal plane because it might shift due to mass effects.) SIEMENS www.usa.siemens.com/healthcare Page 2 of 4 o Right mouse in GSP segment(s) > Select Zoom/Pan > Left mouse Zoom and Center selected image(s) o Zoom: Left mouse and hold at periphery o Pan: Left mouse and hold at center o Zoom/Pan image(s) inside the dotted yellow box (picture frame) o Click camera icon on each displayed image to save individually (Or) o Click “all segments” in Capture dialog box to save all images at once Patient Applications Transfer Edit Queue Protocol View Image Tools Evaluation Scroll System Add-On Options Help 75.08.20:40-STD-1.3. HAL 14.02.04-08:20:40-STD-1.3 ... Fest HAL 94.02.04.08.20:40-STD-1.3 AFL IMA 213 o RHA .... 73 MPRINDUNORM OV 8658 POMPRINDINORM AAHend Scout_MPR_129 Foy SP F16 test 2/4/1970 Dot TA: 2:28 PM: REF PAT: Off Voxel size: 0.7:| x Coils Miscellaneous Adjustment all segments Exit Capturing Mode o Default region > Specific guidance text o Text drop down > Select Default Text o e.g., Abdomen, Angio, Brain, Breast, Cardiac, Knee and User-defined o Select icon for bullets, numbering, alignment, and font for guidance text SIEMENS Dot Add-In Configurator t1_f12d_sag EE Copy Paste Layout 3 images Text sag Guidance Slices are aligned by AutoAlign. o Edit Customized Text o Highlight text > select Delete key o Type in new customized text SIEMENS Dot Add-In Configurator t1_f12d_sag En Copy Paste Layout 3 images Text sag Guidance Slices are aligned by AutoAlign. Note that if you change slice positions manually, it might be impossible to reproduce these exact Parameters slice positions for subsequent protocols and follow-up examinations. Sagittal slices are aligned with the mid-sagittal plane as defined by the symmetry of the skull. (The Queue interhemispheric fissure is not used for the alignment of the mid-sagittal plane because it might shift due to mass effects.) GSP Tonitin Tonkin Tooltin SIEMENS www.usa.siemens.com/healthcare Page 3 of 4 o Add a Tooltip for Guidance Images SIEMENS Dot Add-In Configurator o Select Tooltip icon t1_f12d_sag o User defined-text En Copy N'aPaste Select predefined text Layout 3 images ES Te o (internationalized) Guidance Slices are aligned by AutoAlign. Note that if you change slice positi Parameters slice positions for subsequent prot Sagittal slices are aligned with the Queue interhemispheric fissure is not use due to mass effects.) GSP Tooltip ... Series Label . User-defined text Auto load Select predefined text (internationalized) o Add Customized Guidance Images from file source o Select Load File (e.g., folder icon) o Select “Find in” to locate file > select file > Open oad File X Tooltip ... Find in ... Load File X C:\Medcomitemp\CDR_OFFLINE\ Picture name: Open Pictures of types: *. bmp;" png:" jpg:".jpeg:" gif Cancel o Select > Close to exit Dot Add-in Configurator o OK > Saves changes 8. Delete Current Guidance Images o Right mouse on guidance image > select reset SIEMENS www.usa.siemens.com/healthcare Page 4 of 4

  • MAGNETOM Avanto
  • MAGNETOM Aera
  • MAGNETOM Skyra
  • MAGNETOM Verio