Daily Shutdown and Start-Up Procedure - Symbia Intevo and Intevo Bold
This job aid document will assist the user of a Symbia Intevo and Intevo Bold
scanner on the VB21 software version in the shutdown and start-up procedures.
Daily Shutdown and Start-up Procedure Symbia Intevo and Intevo Bold (VB21 s/w) Description: This job aid document will assist the user of a Symbia Intevo and Intevo Bold scanner on the VB21 software version in the shutdown and start-up procedures. Shutdown Procedure 1. From the MI Apps Comand Module, select Options -> End Session es Options System Help Version ... License .. File Browser ... Maintenance ... ate End Session .. se Configuration ... ites Service Im Notes Muncardial DA 2. Click Shutdown System End Session Log Off. Shutdown System. Restart System. Restart Application Standby Cancel Help 3. Click Yes to confirm system shutdown. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 SIEMENS Job aid: Effective Date: X01/18/2019 | HOOD/HILS HOOD05162002981351 Healthineers Daily Shutdown and Start-Up Procedure-Symbia Intevo VB21 Effective Date: 01/18/2019 | HOOD/HILS HOOD05162002981351 4. Once workstation shuts down completely, press and hold the power button on the acqui- sition console’s UPS to shut off. E.T.N 5. Select the Setup Tab on the PPM (Patient Positioning Monitor) 6. Select Shutdown Shutdown Touch Pad Test X Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 7 Daily Shutdown and Start-Up Procedure-Symbia Intevo VB21 Effective Date: 01/18/2019 | HOOD/HILS HOOD05162002981351 7. Select Proceed. x 8. Wait for the PPM to display OK to Shutdown message. 9. Flip SNAC switch to Off SNAC 10. Flip the CT Subsystem Power toggle to Off CT Subsystem Power Switch Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 7 Daily Shutdown and Start-Up Procedure-Symbia Intevo VB21 Effective Date: 01/18/2019 | HOOD/HILS HOOD05162002981351 Start-up Procedure 11. In the control room, press and hold the power button on the acquisition counsole’s UPS to turn it on. 12. Flip SNAC switch to ON SNAC 13. Press Green Restart Button (1) to clear the Emergency Stop 2 14. Turn the CT Subsystem Power toggle to ON CT Subsystem Power Switch Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 7 Daily Shutdown and Start-Up Procedure-Symbia Intevo VB21 Effective Date: 01/18/2019 | HOOD/HILS HOOD05162002981351 15. Login to the Acquisition Console: Username: esoft · Password: $USER$pwd$45$med$ · Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 5 of 7 Daily Shutdown and Start-Up Procedure-Symbia Intevo VB21 Effective Date: 01/18/2019 | HOOD/HILS HOOD05162002981351 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 6 of 7 Daily Shutdown and Start-Up Procedure-Symbia Intevo VB21 Effective Date: 01/18/2019 | HOOD/HILS HOOD05162002981351 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 7 of 7
- Daily Shutdown and Start-Up Procedure - Symbia Intevo and Intevo Bold