Dimension Vista® System Other Maintenance Online Training
Other Maintenance Procedures are available to troubleshoot and maintain the system. This clinical laboratory training qualifies for continuing education units (CEU).
Clean the Aliquot Drain Distinguish between three sensor types for replacement Perform maintenance of the Water Purification Module (WPM) system components Perform miscellaneous maintenance tasks Replace a fuse Welcome to the Dimension Vista® System Other Maintenance Online Training Course. After completing this course, you will be able to: Select Next to continue. Congratulations. You have completed the Other Maintenance Online Training Course. Once you have reviewed the content on this page, you may proceed to the assessment portion of the course. Tip: Print this page for reference. In this course, you have learned how to: Perform a controlled shutdown and startup of the Dimension Vista® System: Shutdown the instrument under the Operation menu and follow prompts on screen to complete instrument shutdown. Open the far right instrument door to turn power switch to instrument off. When task is completed, turn power switch to on and the Dimension Vista System will start automatically. A controlled shutdown will save all current data and alignments on the system. Locate and replace a fuse: Fuses help prevent damage to the various system components if they become exposed to excessive current. Generally, a Technical Solutions Center representative will assist you in identifying the fuse that needs to be replaced. The AC/DC boards are located to the left of the instrument main power switch. Spare fuses are in the spare parts kits. Ensure the new fuse is of the correct type, voltage and current rating. Distinguish between the three types of sensor attachments and replace a sensor: Optical sensors monitor position and movement of the various components on the instrument. There are four possible types of attachments for the sensors; T10 screws, spring clip, and latches. Perform a controlled shutdown of the instrument prior to replacement. In most situations, a Technical Solutions Center representative will assist you in locating the sensor that requires replacement and verifying it is operational. Clean the aliquot drain: Over time, debris from the aliquot probe will accumulate and may require that the aliquot drain be cleaned. A clean out tool and stylet are needed to follow the procedure in the Operator’s Guide. Miscellaneous Maintenance Tasks: These tasks may need to be performed periodically in response to process errors. These tasks include: Routine IMT Clean Prime IMT System Pump Liquid Waste Select Next to continue. Now that you can identify the functions of various Diagnostics IT Systems, let’s head to the clinical laboratory to see how Diagnostics IT products facilitate laboratory workflow by taking a look at the typical lifecycle of a patient test—from ordering the test to reporting the result. In our “virtual” laboratory, you’ll see how a network of Diagnostics IT Systems interacts to effectively manage the many stages of data transfer that occur every day in a busy healthcare facility, such as when entering patient order information, querying for sample ID, and transmitting results. WPM Maintenance: The three main WPM components that require periodic maintenance include: Progard®Pretreatment Pack Q-Gard®Polishing Pack RO Membrane Maintaining WPM Components Learn how to maintain the components of the WPM on the Dimension Vista® System. Checklist TitleChecklist TypeChecklist ContentReplace Progard® Pretreatment PackHTML Navigate to the Supplies screen by pressing the Alert or selecting Setup > Supplies. Select Maintain Water Supply > Maintenance. Open the left instrument door; lift up the metal ring in front right corner of tray to release and pull forward. The Progard® Pretreatment Pack is on the left. Follow instructions on screen to replace and record in the Instrument Log. Replace the Q-Gard® Polishing PackHTML Navigate to the Supplies screen by pressing the Alert or selecting Setup > Supplies. Select Maintain Water Supply > Maintenance. Open the left instrument door; lift up the metal ring in front right corner of tray to release and pull forward. The Progard® Pretreatment Pack is on the left. Follow instructions on screen to replace and record in the Instrument Log. Sanitize the RO MembraneHTML Navigate to the Supplies screen by pressing the Alert or selecting Setup > Supplies. Select Maintain Water Supply > Maintenance. Open the left instrument door; lift up the metal ring in front right corner of tray to release and pull forward. Always place the chlorine tablet in the first RO membrane and use tool to open. Follow instructions on screen to sanitize the RO membrane and record in the Instrument Log. Collecting a Water Sample Learn about performing a Water Sampling of your Dimension Vista® System. A procedure has been added to the Operator’s Guide for the collection of a water sample to test the bacterial count of the water being supplied to the Dimension Vista® System. This is performed under Advanced > Diagnostics > Vista Diagnostics. The sample is collected from the Reagent Arm 2 Probe Assembly. When complete, select the X in the upper-right corner to close the window and continue. Miscellaneous Maintenance Tasks: Routine IMT Clean Prime IMT System Pump Liquid Waste TIP: Refer to the iGuide for more details on these individual maintenance tasks Miscellaneous Maintenance Tasks Learn how to perform Miscellaneous Maintenance Tasks on the Dimension Vista® System. Checklist TitleChecklist TypeChecklist ContentRoutine IMT CleanHTML Routine IMT cleaning is normally completed during nightly activities. However, this procedure may need to be performed when responding to a system error. Select System > IMTCalibration > Maintain IMT, select IMTRoutine Clean, and select Next. When complete, select Finish. Prime IMT SystemHTML It may be necessary to Prime the IMT System fluids if they ran dry or while performing IMT troubleshooting. Select System > IMTCalibration, thenselect Maintain IMT, select Prime IMT and follow the screen prompts. Pump Liquid WasteHTML It may be necessary to manually pump liquid waste in response to a system error. Select Setup > Supplies, select Pump Waste, select Pump for the waste to be emptied, select Finish and liquid waste will continue to pump from the system. The Aliquot Drain may require cleaning in response to certain processing errors. The tools required to properly clean the drain include: Aliquot Drain Clean out Tool Aliquot Drain Clean out Stylet Why does a red temperature alert appear after the Aliquot Drain has been cleaned? Cleaning the Aliquot Drain Learn how to clean the Aliquot Drain on the Dimension Vista® System. Checklist TitleChecklist TypeChecklist ContentNavigate to Vista DiagnosticsHTML Navigate to Advanced > Diagnostics > System Diagnostics > Vista Diagnostics > select the PROCS tab > select Replace Probes Note: Select all of the tabs in the checklist to view key steps in cleaning the Aliquot Drain. Select Replace Aliquot Probe on the PROCS tabHTML Select Aliquotter Replace Probe. Note: This will position instrument to provide access to the Aliquot Drain for cleaning. Clean the Aliquot DrainHTML Cancel Probe ReplacementHTML Select Cancel once the Aliquot Drain is cleaned. This will place the Aliquot Probe back in the correct position. Exit DiagnosticsHTML Exit Diagnostics and Reset the instrument by selecting Reset in the Operation menu. Proper fuse replacement requires the following steps: Identify fuse needing replacement Perform a controlled shutdown of the instrument Replace fuse Restore power to instrument Note: This procedure is instrument specific and needs to be performed on the side of a Dimension Vista® 1000T/3000T System that is having the error. Pressing Shutdown will shutdown both the left and right instruments. Replacing a Fuse Learn how to replace a fuse on your Dimension Vista® System. Slide NumberText BlocksCalloutsAudio ScriptImage File1Key steps of fuse replacement: Shutdown the instrument Locate the instrument power switch Note: Select the location of the instrument power switch in the picture to the left.Note: If audio does not automatically start, select the play arrow in the top left to begin.Welcome to the virtual Chemistry Lab! Before we can begin replacing the fuse, a controlled shutdown of the instrument must be performed. A controlled shutdown is important because it will save all current data and alignments on the system. The Operation menu allows you to begin the instrument shutdown. Simply follow the prompts on the screen to complete the shutdown process. Next, the power to the instrument needs to be turned off. Do you remember where the main power switch for the instrument is located? 2Key steps of fuse replacement: Locate fuse that needs to be replaced Turn the instrument power switch OFF Select Next to continue.TIP:If an LED for a fuse is not illuminated, it does NOT indicate a bad fuse. These will only illuminate when that particular module of the instrument is in use. CalloutsAC BoardDC BoardPower SwitchThat’s correct; the main power switch to the instrument is located behind the far right instrument door. The fuse boards are located to the left of the power switch. The AC board is on the left and the DC board is on the right. Your Technical Solutions Center Representative will assist you in locating the fuse that needs to be replaced. Spare fuses are included in the spare parts kit.3Key steps of fuse replacement: Turn fuse holder counterclockwise to release Remove old fuse and replace Screw holder back in place Select Next to continue.TIP: Refer to the iGuide for detailed information on fuse types. Use a screwdriver to turn the fuse holder counterclockwise to release. Remove the used fuse from the holder and replace it with a new fuse. Be sure to replace with a fuse that is the same type and has the same voltage and current rating. The iGuide can provide further information on fuse types on the Dimension Vista System4Key steps of fuse replacement: Restore power to the instrument Click the power switch Note: Select the instrument power switch in the picture to the left.When you have replaced the fuse, the instrument power switch can be turned back on. The Dimension Vista System will start automatically.5You have just learned how to:Perform a controlled shutdown of the instrumentLocate and replace a fuseRestore power to the instrumentWhen complete select the X in the upper-right corner to close this window and continue.You’ve just learned how to perform a controlled shutdown and startup of the instrument. You also learned the key steps that are involved in locating and replacing a bad fuse on your Dimension Vista System. Key Steps of Sensor Replacement on the Dimension Vista® System: perform a controlled shutdown of the instrument open the instrument lids locate the sensor that needs to be replaced Three types of Sensor Attachments: T10 screws Spring clip Latch Sensor Types Review the appropriate replacement procedure for each attachment type. Tab TitleTextT10 Screws Key steps for sensor replacement: After the instrument is shutdown, lift instrument lid and locate sensor. Disconnect the sensor. Remove the screws and lift out the sensor. Replace with new sensor and tighten screws. Reattach sensor and close instrument lid. Turn instrument power on. Spring Clip Key steps for sensor replacement: After the instrument is shutdown, lift instrument lid and locate sensor. Disconnect the sensor. Loosen screw that holds clip and rotate clip out of the way by pulling it, being careful not to bend the clip. Slide out sensor and replace. Reposition clip and tighten screw. Reattach sensor and close instrument lid. Turn instrument power on. Latch Key steps for sensor replacement: After the instrument is shutdown, lift instrument lid and locate sensor. Disconnect the sensor. Push down on latch and slide sensor to the right. Replace with new sensor and reattach connector. Close lid and turn instrument power on. When complete, select the X in the upper-right corner to close the window and continue.
- vista maint
- maint
- fuse
- sensor
- T10 screw
- spring clip
- latch
- alliquot drain
- wpm
- water purification maintenance
- Progard pretreatment pack
- Q-Gard Polishing pack
- RO membrane
- water sample