Dot Cockpit - Add Generic Views Snapshots - E-Line
This Job Aid provides workflow to add Guidance Images to a sequence in the Dot Cockpit.
Dot Cockpit > Add Generic View Snap- shots to Dot Sequences – E-Line Job Aid Dot Cockpit > Add Generic View > Snapshots to Dot Sequences – E-line Job Aid This Job Aid provides workflow to add Guidance Images to a sequence in the Dot Cockpit. To add Guidance Images, a Generic Views Dot Add-in must be attached to the sequence in the Dot Cock- pit. (Generic Views Dot Add-ins can be dragged and dropped from default add-in list to a se- quence in the Dot Cockpit) 1. Register a Patient 2. Scan Queue a. Run any sequence(s) needed to create guidance images i. Load these images into the GSP segments b. Open Sequence you want to add guidance images to Brain Dot Engine 3/3/1944 Dot X AAHead_Scout 2 @_ 11_f12d_sag 3 %_ 12_tse_tra_p2 01:26 4 % t2_tirm_tra_dark-fluid 04:32 5 % ep2d_diff_3scan_trace_p2 01:38 c. Select View > Image Text On (Removes Text from images in GSP) i. Note: Checkmark is removed in front of “Image Text On” Patient Applications Transfer Edit Queue Protocol | View | Image Tools Evaluation Scroll System Add-On Options Help HAR 2 Segments ARF 3 Segments Exam Maestro UI Cardio UI HE2 Tim Planning UI Spine Planning UI AGS Image Text On AGS Reference Lines On Viewing Protocol Table Position On RP Coil Positions On Adjust Volume On Graphics CSI Matrix Position Toolbar. NET Inline Display ... Film Table Positioning NE2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Job Aid | Dot Cockpit – Add Generic View Snapshots to Dot Sequences – E-Line Effective Date: 02/05/2021 | HOOD05162003158301 d. Adjust and Position the Scan Region for images in the GSP segments i. FOV ii. Slices, Coverage, and Angulation iii. Coils Patient Applications er Edit Queue Protocol Scroll Add-On Options Help HAR HAR ARF Exam HE2 ASS AGS Viewing RPF -- o --- ................................................................ Film NE1 NE2 3. Select Dot Cockpit Icon a. Navigate to User > Region > Exam > Program > Sequence (to add Guidance Views) b. Explorer > Browse > select Edit Icon i. Reduce size of Dot Cockpit window and position below GSP image segments Dot Cockpit - Explorer EXPLORER PROGRAM EDITOR exact Browse Import Export ull. (The USER USER > sweet > Head_DotEngine > Brain Dot Engine Edit might Q Des Patient View + Basic Patient View sweet V Standard Speed focus › t_spine Shoulder_DE_Routine AAHead_Scout o AutoAlign S I_ spine Knee 2D 11_f12d_sag 01:25 11_f12d_sag_p2 hip_left_unilateral Generic Views Generic Vi Head_DotEngine t2_tse_tra_p2 01:26 t2_haste tra_p2 Brain Dot Engine Generic Views 2 Generic Vi Head t2 tirm tra dark-fluid 04:32 t2_tirm_tra_dark-fluid_p3 c_spine Generic Views 2 + Generic Vi Breast ep2d_diff_3scan_trace_p2 01:38 ep2d_diff_3scan_trace_p2 abdomen Generic Views 22 Generic Vi › ankle head coil 11_f12d_tra 01:19 11_112d_tra_p2 elbow Dot Cockpit Generic Views 2 Generic Vi Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Page 2 of 7 Job Aid | Dot Cockpit – Add Generic View Snapshots to Dot Sequences – E-Line Effective Date: 02/05/2021 | HOOD05162003158301 c. Program Editor > Edit i. Select Sequence (to add Guidance Views to) ii. Generic Views > Right Mouse > select Edit Properties iii. Move window so positioned below GSP image segments Dot Cockpit - Program Editor (Program Path = USER/sweet/Head_DotEngine/ EXPLORER PROGRAM EDITOR Edit Simulate Standard USER >> sweet >> Head_DotEngine >> Brain Dot Engine x Dot Patient View Basic Patient View V Standard Speed focus AAHead_Scout Auf t1_f12d_sag 1:25 t1_f12d_sag_p2 e Generic Ctrl+C + G 12_tse_tra_p2 Copy Generic Paste Ctrl+V . G t2_tirm_tra_dark-fluid Delete luid_p . Generic View Properties .. .G ep2d_diff_3scan_trace_p2 Edit Properties .. face_p2 . Generic Views OG t1_f12d_tra 01:19 t1_f12d_tra_p2 . Generic Views 4. Step Properties window a. Select AddIn Configuration button Step Properties USER > sweet >> Head_DotEngine >> Brain Dot Engine > 11_f12d_sag F 1 Identical > General TA: 1:25 PM: REF PAT: Off Voxel size: 0.7x0.7x4.0mm Rel. SNR: 1.00 Protocol Parameters Voice Commands Guidance Parameters Execution Slices are aligned by AutoAlign. Note that if you change slice positions manually, it might be impossible to reproduce these exact Image Management slice positions for subsequent protocols and follow-up examinations. Sagittal slices are aligned with the mid-sagittal plane as defined by the symmetry of the skull. (The Auto Load interhemispheric fissure is not used for the alignment of the mid-sagittal plane because it might Copy References shift due to mass effects.) Preview Addin Configuration. OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Page 3 of 7 Job Aid | Dot Cockpit – Add Generic View Snapshots to Dot Sequences – E-Line Effective Date: 02/05/2021 | HOOD05162003158301 b. Add-In Configurator window i. Move window so positioned below GSP image segments ii. Select Guidance iii. Layout > select 1 to 3 images from dropdown iv. Select Camera Icon OSIEMENS Dot Add-In Configurator ? X EE Copy Paste Guidance Layout | 3 ima .. Text tra Parameters Slices are aligned by AutoAlign at the level of the corpus callosum and along a line through the Queue genu (anterior) and the splenium (posterior). GSP Note that if you change slice positions manually, it might be impossible to reproduce these exact slice positions for subsequent protocols and follow-up examinations. Series Label Auto load . Tooltip ... / Tooltip .. = Tooltip ... AutoCoverage AutoTiming Close HE1 HAR HE2 c. Zoom/Pan and/or Resize the image in the GSP Segment i. Select Camera Icon in each GSP seg- ment ii. Check Size and Placement of Guid- ance Image in segment ASS • Ensure Captured image is lo- cated inside the dotted or- AFR ange box NE1 NE2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Page 4 of 7 Job Aid | Dot Cockpit – Add Generic View Snapshots to Dot Sequences – E-Line Effective Date: 02/05/2021 | HOOD05162003158301 d. Select Capture All Segments i. Images in each segment are loaded into the Guidance Images segments of the Dot Add-In Configurator the Dot Cockpit. HAR HAR ARF RSS ASS AFR RPF RPF ...... ............ Brain Dot Engine 3/4/1955 Dot TA: 1:26 PM: REF PAT: 2 Voxel size X Guidance Parameters all segments Exit Capturing Mode e. Dot Add-in Configurator > Guidance window i. Check Guidance Image placement ii. Select Close SIEMENS Dot Add-In Configurator ? X EE Copy Paste Guidance Layout 3 ima ... Text sag Parameters Slices are aligned by AutoAlign. Queue Note that if you change slice positions manually, it might be impossible to reproduce these exact GSP slice positions for subsequent protocols and follow-up examinations. Sagittal slices are aligned with the mid-sagittal plane as defined by the symmetry of the skull. (The Series Label interhemispheric fissure is not used for the alignment of the mid-sagittal plane because it might shift due to mass effects.) Auto load / Tooltip ... / Tooltip ... / Tooltip .. AutoCoverage AutoTiming Close Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Page 5 of 7 Job Aid | Dot Cockpit – Add Generic View Snapshots to Dot Sequences – E-Line Effective Date: 02/05/2021 | HOOD05162003158301 f. Step Properties window i. Select OK Step Properties ? X USER >> sweet >> Head_DotEngine >> Brain Dot Engine >> 11_112d_sag F 1 Identical >> General TA: 1:25 PM: REF PAT: Off Voxel size: 0.7x0.7×4.0mm Rel. SNR: 1.00 Protocol Parameters Voice Commands Guidance Parameters Execution Slices are aligned by AutoAlign Note that if you change slice positions manually, it might be impossible to reproduce these exact Image Management slice positions for subsequent protocols and follow-up examinations. Sagittal slices are aligned with the mid-sagittal plane as defined by the symmetry of the skull. (The Auto Load interhemispheric fissure is not used for the alignment of the mid-sagittal plane because it might Copy References shift due to mass effects.) Preview HEZ E1 D Addin Configuration ... OK Cancel 5. Dot Cockpit > Program Editor window a. Select Save Program Icon b. Close Dot Cockpit (or) select another Sequence to add Guidance Views Dot Cockpit - Program Editor (Program Path = USER/sweet/Head_DotEngine/Brain Dot Engine) ? X EXPLORER PROGRAM EDITOR Edit Simulate =Standard USER >> sweet >> Head DotEngine >> Brain Dot Engine Save program X Browse Search Default bot Patient View Basic Patient View USER Standard Speed focus AAHead_Scout . AutoAlign S sweet t1_f12d_sag 01:25 t1_f12d_sag_p2 . Generic Views . Generic V t2_tse_tra_p2 01:26 t2_haste_tra_p2 . Generic Views 2 o Generic V t2_tirm tra_dark-fluid 04:32 t2_tirm_tra_dark-fluid_p3 Generic Views 2 . Generic V ep2d_diff_3scan_trace_p2 01:38 ep2d_diff_3scan_trace_p2 + Generic Views .Generic V select a program or library t1_f12d_tra 01:19 t1_f12d_tra_p2 + Generic Views 2 Generic V contrast agent contrast agent Strategy Decision with contrast agent with contrast agent inject contrast agent inject contrast agent Interaction Pause Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Page 6 of 7 Job Aid | Dot Cockpit – Add Generic View Snapshots to Dot Sequences – E-Line Effective Date: 02/05/2021 | HOOD05162003158301 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 02/05/2021 | HOOD05162003158301 Healthineers Page 7 of 7
- MR
- Dot
- Cockpit
- Generic
- Views
- Snapshots
- Eline