epoc® Blood Analysis System Performing a Capillary Whole Blood Test Video
This video will show you the procedure on how to perform a capillary whole blood test on the epoc® Blood Analysis System.
Performing a capillary whole blood test on the epoch blood analysis system. This module covers obtaining a capillary whole blood sample and delivering the sample into the epoch test card. For a full description of the testing process, please view module 3. Obtain all appropriate supplies for performing a capillary puncture, including the epoch care. Fill capillary tube. Note do not remove, reposition or depress plunger. Also, do not remove adapter. Always hold the tube at the blue band and do not hold or handle by the plunger. Perform a capillary puncture procedure according to facility policy. Fill the tube until the blood sample contacts the white porous plug. Ensure that the tube remains vertical so that no air bubbles are introduced. The capillary tube should be held vertically. Once the capillary tube is filled completely, hold the capillary tube by the blue band pointing the tip of the capillary tube upward so that it is now vertical. Slide the adapter towards the end of the capillary tube and insert the capillary tube tip into the adapter. Hold the capillary tube. By the adapter pointing the tip of the adapter into the test card sample port, rotate the adapter a quarter turn to ensure a proper seal has been made between the test card and the adapter. Maintain hold of the adapter and using the fingers of your other hand, push the plunger down completely using one single motion. Continue to hold the plunger completely down while waiting for the reader to beep. After the reader has beeped disengaged the capillary tube from the card by tilting it as opposed to pulling it straight up. The host displays analyzing sample once analysis is complete, test results will display on the epoch host screen. If the prompt enter patient ID to view test results is displayed. Enter the ID number and tap the save icon. Then results will appear on the screen. Note that other fields may also be required. Follow prompts to complete and save. Depending on tests selected, the results will display in tabular form. Tabs are gases chemistries. And metabolites. If a test was not selected but as needed. Tap on the test selection tab. Tap on the checkbox for the test desired and tap save. Additional information can be added and saved at this time. Once the test results display, the test card can be removed at anytime. Dispose of the testcard in a biohazard disposal receptacle. When all testing with the epoch reader is complete and all data entries are made, the test is closed by tapping on the red X at the top right to close the epoch reader screen for that reader. Tap on the logout icon, Green Arrow pointing to an open door to disconnect from the epoch reader. Note that closing the test permanently saves the test and changes to that test are no longer possible. If desired, turn off the epoch reader and epoch host using the power buttons.
00 14:57 14:57:27 14:58 14:59 7.005 15:01 91 15:02 #06924 Performing a Capillary Whole Blood Test BLOOD ANALYSIS epoc Sterile Pad 12 Ply (50 mm x 50 mm) Capillary Tubes 90uL Tampon stérile 50 x 50 mm 12 épaisseurs Made in Canada (2 x 2 po) Gasa estéril Made in China/Fabriqué en Chine/Hecho en China according to facility policy. Perform a capillary puncture procedure epoc Host 03-Mar-17 Pat ID AC83130041 Blood BGEM Analyzing sample 32s Analyzing sample ... epoc Readers Rdr6924 (06924) Tools View Help BKSP 29s Test completed. Calculating results. Please wait. Pat ID To view results: - Enter patient ID. Press SAVE when done. epoc Readers Rdr6924 (06924) ID2 Hemodilution Yes O No Sample Arterial Temp Reject test Comments Gases+ Chem+ Meta+ pH pCO2 66.4 mmHg 95.0 mmHg 16.6 mmol/L BE(ecf) -14.6 mmol/L 91.7 % cSO2 DE DEF cTCO2 BE(b) -10.2 mmol/L No Results 03-Ma Select tests to perform .... Crea Hct Na+ K+ Ca++ Glu Lac 03-Mar-17 14:57:27 DCO Fisherbrand DANGER REGULATED MEDICAL WASTE BIOHAZARD Cat. No. 22037959 2 GALLON INFECTIOUS WASTE CONTAINER pO2 Rdr6924 #06 Warning Logging out. Continue? Yes No Enter user ID and password. User ID Password Login epoc Host 3.24.4 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright C Siemens Healthcare GmbH 2018 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers SIEMENS Health Healthineers
- epoc
- blood
- analysis
- system
- capillary