epoc® Blood Analysis System with NXS Host Performing a Capillary Blood Test Video
This video will show you the steps on how to perform a capillary blood test on the epoc® Blood Analysis System with NXS Host.
This video will introduce you to the steps on how to perform a capillary blood test on the epoch with xhost blood analysis system. To perform a capillary blood test you will need the following supplies. The Epoch Knicks host. The epoch reader. A new epoch testcard and an epoch. Careful capillary tube. Please wear the proper personal protective equipment when handling any patient blood specimens. To start, press the power switch to turn on the epoch reader. The power LED will turn green, indicating the epoch reader is on and ready for use. Next turn on the host by pressing the power button located on the upper right side of the host. Sign into the epoch host using your sign in user ID and password. Or by scanning your user ID barcode. When the host connects to a selected reader, the test status indicator will turn solid green. This means the reader is ready for use. Next, the host will display a test screen. The screen will then show insert new test card. Select a test card. And remove it from the pouch. Be sure to not touch the sensor modules contact surface or the blood sample entry port. Hold the test card facing the sample port upwards. Insert the test card into the card slot of the reader by firmly pushing it in using a smooth single motion. This will enable the barcode on the card label to be read correctly by the epoch reader. Be sure to lock the card into place once the card is locked into place, the reader will beep once. The host screen will then display the card lot number and the test status indicator light will start flashing green. Next, the host screen will show that the system is calibrating. Do not inject the sample into the card until calibration is complete. The calibration process takes approximately 165 seconds to complete. Once calibration is complete, the system will beep twice. The host will display and inject sample message and countdown timer on the screen. Do not remove, reposition, or depress the plunger. Also, do not remove the adapter. Always hold the tube at the blue band and do not hold or handle by the plunger. Perform a capillary puncture procedure according to facility policy. Once the capillary tube is filled completely, hold the capillary tube by the blue band and point the tip of the capillary tube upward so that it is vertical. Slide the adapter towards the end of the capillary tube and insert the capillary tube tip into the adapter. Holding the capillary tube by the adapter, insert the adapter into the test card sample port. Rotate the adapter a quarter turn to ensure a proper seal has been made between the test card and the adapter. Maintain hold of the adapter and using the fingers of your other hand, push the plunger down completely using a single smooth motion. Keep the plunger pushed down until you hear the reader beep. If the sample is injected into the card too soon or too late, an error message will appear and the system will abort the test. Once you hear the reader beep, disengage the capillary tube from the test card by tilting as opposed to pulling it straight up in order to prevent a suckback effect from happening to the sample. The epoch system will then display analyzing sample on the host screen. Once the analysis is complete, test results will display on the Epoch host screen. While the sample is being analyzed and are the patient ID into the host, once the information has been entered into the host, a check mark will be visible on the blue circle and the patient ID is shown in the action bar. Patient ID can also be viewed in the edit test details section of the software. Answer yes or no to the hemodilution question and press confirm to proceed with the blood test. Next, choose select test in the software. Select the test panel from the list, select the proper buttons to customize the test options. Select confirm once all information has been entered. Other patient information, such as patient age, gender and height can be entered into the edit Test detail section. If temperature correction is needed, that information can be entered into this area as well. Once complete, select confirm in the software. The test card can be removed once the test results are displayed on the host screen. When all testing with the epoch reader is complete and all data entries are made, the test is closed by tapping on the save and close button. The X in the top left corner can also be used to close the test. Select sign out icon to sign out from Epoch host. Note that closing the test permanently saves the test and changes to that test are no longer possible. This completes the performing a capillary blood test video for the epoch blood analysis system with Nick's host.
12 123 1234 2021-12-24 11-21190-40 00 2123 212 95% 15:23 00:3 97% 98% 92% 7.35 10.3 97.4 13.3 -2.2 99.9 128 15 1.05 13.6 20 100% epoc® with NXS Host Blood Analysis System Performing a Capillary Blood Test Video epoc BLOOD ANALYSIS CE (o) 11-Aug-21 14:10 Version 4.6.4 About User ID Scan SIGN IN 1 2 3 4 5 6 7 8 9 0 ABC 2 3 4 5 3 4 5 6 7 8 90 h j k Regional Bryan Degala RADIOLOGY 11-Aug-21 14:16 X Blood Test: Rdr26415 n m Configuring Rdr26415. Do not insert You can edit Test Details now. Edit Test Details Patient ID * Required to view results Scan or enter Patient ID Select Hemodilution * card. 10s remaining. g h j k l card. 1s remaining a sd C V Insert new Test Card. Show me how v b a s d REF 10736515 Na+ Glu K+ Lac p02 Ca+ + Crea BUN LOT 11-21190-40 Epocal Inc. Ottawa, ON Canada p02 Ca+ + Cr Crea Ca + + 11-Aug-21 14:35 Show less Reader: Rdr26415 78% battery Test Card inserted. Lot 11-21190-40 Select Sample Type Enter patient information Enter sample information q v Test Card inserted Calibrating. Do not inject sample 02:52 remaining z x Z x w e q w h j k l 11-Aug-21 14:58 00:02 remaining a s h j Inject Sample 07:30 remaining 11-Aug-21 15:23 Analyzing sample 00:35 remaining qwert qwerty t y Next emodilution * 6 8 X Patient 1234 O No Edit Patient temperature, age, gender, height No Select tests Required fields completed Arterial Venous Mixed-venous cord Cord Arterial Cord Venous Unknown Gases+ Electrolytes Custom Selection Chem+ eMP PH Ca++ TCO Enter respiratory information information Capillary Gases Draw site, Allen's test Delivery system, Mode, FiO2, Flow, RQ, .. Enter Comments Con 9-Apr-21 09:42 X Patient AC12345678 CLOSE & REPORT REJECT TRANSMIT CRITICAL RESULTS TEST pH mmol/L BE(ecf) Hct CRITICAL RE 11-Aug-21 15:47 Patient 1234 SAVE & CLOSE RESULTS iQC cnc BE(b) show YES Run Blood Test View Blood Test History Settings About Sign Out QA Testing gn Out Do you wish to sign out? NO n Out wert asdf g h ui o p Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. C Siemens Healthcare GmbH 2022 SIEMENS Healthineers
- epoc
- blood
- gas
- capillary. NXS