PEPconnect

epoc® Blood Analysis System with NXS Host Performing External Liquid Quality Control Video

This video will show you the steps on how to perform the external liquid quality control procedure on the epoc® Blood Analysis System with NXS Host.

This video will introduce you to the steps on how to perform external quality control on the epoch blood analysis system with Nix host. To start, ensure you have the most current evad sheets downloaded and printed. Next, select the QA testing item button on the home screen, select run QA test. Insert a test card into the reader. Ensure the correct lot number of the ampule is entered into the system. This can be done by scanning the barcode on the ampule, or manually entering it into the system using the host keyboard. Next, select the specific type of solution that will be running in the software. Select select tests and confirm the correct test has been chosen. While calibration is completing hold, the ampule between the thumb and index finger shake the ampoule vigorously for 15 seconds to re equilibrate the gases with the solution. Ensure this is done right before running the test. Allow bubbles to rise before opening the ampule. Swirl the ampule gently in order to return the solution to the bottom of the ampule. Hold the ampule with the colored dot facing up, snap off the neck of the ampule in the opposite direction of the color dot. Transfer the one milliliter of fluid from the bottom of the ampule into a plain syringe by aspirating it through a large bore needle or a blunt tip. Ensure the syringe is kept in a vertical position to ensure any air bubbles trapped. Do not move through the fluid. Moving air bubbles contaminate the fluid. Next, remove the needle from the syringe and expel a few drops of the fluid onto a paper towel or tissue. Fit the syringe, lure into the test card. Sample introduction port as you would for a whole blood test. Depress the plunger with a single smooth continuous motion until the system prompts you to stop. Once the test is complete, compare each value to the most current evad sheet that has been printed out. If results are outside of the specified ranges, refer to the troubleshooting and error messages located in the epoch system manual. When testing is complete, remove the test card and dispose per laboratory protocol. Select the saving close button in the software. This completes the video on how to perform external quality control on the epoch blood analysis system with Nick's host.

267.000.005 2022-02-28 7.062 7.002 7.451 7.714 6.644 7.860 60.1 37.8 15.2 120.5 0.0 9.10 8.01 4.04 3.04 5.04 3.03 2.03 16.07 13.18 0.00 52.2 114.4 164.5 42.3 645.0 6.95 15.25 13.14 21.92 5.64 3.53 108 141 135 160 174 7.9 7.3 0.60 3.49 2.4 13.9 12.3 6.2 6.8 11.9 0.7 1.7 2.15 0.12 6.71 5.15 0.15 12.25 1.4 0.11 0.21 0.47 0.73 0.04 0.01 1.11 1.41 164 1265 847 1/28 7.654 7.800 193.5 25.79 86 80 0.25 1.3 115 819 1.2 28.8 0.26 1.08 0.92 1.24 1.20 18.28 0.08 2.75 313 243 22.8 16.0 1.12 1.04 2.1 2.7 131 161 3.00 164. 0.27 4.33 0.02 7.391 98.8 3.7 1.0 0.5 107 0.90 6.64 46.3 0.05 3.54 68.3 68.0 26.5 1.53 2.0 123 146 18.5 0.35 0.45 164.7 14.32 2123 12 1234 10 31 106 22 162 79 145 epoc® Blood Analysis System with NXS Host Performing External Liquid Quality Control Video BLOOD ANALYSIS z x z X epoc® System Value Assignment Datasheet LOT 267-B042 Sensor Configuration 39.n (epoc22045.eVAD) SIEMENS REF Eurotrol™ Calibration Verification Fluids, n = 1 Healthineers CV1:267-1-B038 CV2:267-2-B039 CV3:267-3-B040 R, n = 1 7.391 - 7 7.800 - 7.920 516.0 - 7 68.78 - 103.18 0.02 - 0.92 2022 Siemens Healthcare Diagnostics. All rights reserved. epoc and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. CE 7.391 - 7.511 IVD - 7.511 K+ g/L 11-Aug-21 16:54 Run Thermal QA Test Test History QA Test History Electronic QC History Thermal QA History Choose Reader Refresh Looking for Readers .. Rdr26415 #26415 Rdr13645 #13645 START TESTING 21402677 #20148 - QA Test: Rdr26415 Connecting. Do not insert card. You can edit Test Details now. Edit Test Details Lot # * Required to view results Scan or enter Lot # Scan Select Test Type Quality Control a s d f n m Configuring Rdr26415. Do not insert card card. 10s remaining. Next 3 4 56 7 8 90 ABC Select 2 34 5 6 7 890 Required fields completed O Quality Control Clear Calibration Verification Proficiency Other Select tests Card needed Insert new Test Card. Show me how hide QA Test: Rdr26415 Insert new Test Card Select Test Type / 11-Aug-21 16:55 Test Card inserted. Lot 11-21190-40 Calibrating. Do not inject sample 02:51 remaining GAS-ISE Metabolites Level 1 40 79 7.054 52.0 16.2 2 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. C Siemens Healthcare GmbH 2022 Hea

  • epoc
  • blood
  • analysis
  • system
  • host
  • nxs