epoc® Blood Analysis System with NXS Host Hardware Overview Online Training
This course will introduce you to the major components of the epoc® Blood Analysis System with NXS Host.
Continue Button Untitled Scene Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 ? epoc® with NXS Host Blood Analysis System Hardware Overview Online Training Hardware overview includes identifying major components of the Host and Reader and describing the components and storage methods of the test card. Identify the major components of the Reader 1 Describe the components of the Test Card 3 Identify the major components of the Host 2 Welcome epoc_hardware_welcome.mp3 Welcome to the epoc with NXS host blood analysis system hardware overview online training course. This course will cover the following three objectives. ? epoc Reader The epoc Reader is a simple-to-use raw signal acquisition peripheral. The Reader has a card slot for accepting a Test Card and an Electro-Mechanical Actuation Assembly for engaging the Test Card after it is inserted into the card slot. Select the markers on the left to learn more about the epoc Reader. Docking Pivot The Docking Pivot provides a physical link between the epoc Reader and Host. A pocket in the Docking Pivot accepts the blade section of the Host Cradle. Battery Status Indicator When the Reader is powered on and the battery status indicator shows a solid amber light, the battery to the reader is fully charged. If the Reader shows a flashing amber light, the Reader is powered on and the battery is charging. Test Status Indicator The test status indicator will light up green or red. If the solid green light is visible, the Reader is processing a test. If a solid red light is visible, the Reader shows an error which needs to be resolved before processing tests. Power Button The power button is located on the Membrane switch and lights up solid green when the Reader is powered on. Test Card Slot The epoc Reader has a card slot for inserting test cards. Within the card slot is a card entry switch, a barcode scanner, an electrical contact for contacting the test card sensory module upon insertion and a thermal subsystem for heating the cards measurement region to 37° C during the test. epoc Reader epoc_hardware_reader.mp3 The epoc® Reader is a simple-to-use raw signal acquisition peripheral. The Reader has a card slot for accepting a Test Card and an Electro-Mechanical Actuation Assembly for engaging the Test Card after it is inserted into the card slot. Select the markers on the left to learn more about the epoc® Reader. ? epoc Host The epoc NXS Host is a dedicated use mobile computer with the epoc Host software application installed. The epoc Host can communicate with the epoc Reader wirelessly via Bluetooth, can calculate analytical values from sensor data sent by the epoc Reader and displays test results. Select the numbered steps below to learn more about the epoc NXS Host. 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 epoc Host epoc_hardware_host.mp3 The epoc NSX Host is a dedicated use mobile computer with the epoc Host software application installed. The epoc Host can communicate with the epoc Reader wirelessly via Bluetooth, can calculate analytical values from sensor data sent by the epoc Reader and displays test results. Select the numbered steps below to learn more about the epoc NSX Host. epoc_hardware_battery.mp3 Rechargeable Battery Layer: The epoc Host contains a Lithium Ion rechargeable battery that is located inside the host. In order to charge the battery, the Host Cradle Blade, located on the bottom of the Host, must be inserted into the Docking Pivot located on the Reader. An LED charging indicator located on the top right corner of the Host shows when charging is in progress and when complete. Several hours may be required to fully recharge the battery. The Host can be operated normally while charging. epoc_hardware_barcodescanner.mp3 Barcode Scanner Layer: The Barcode Scanner allows the user to scan text, such as a patient ID, directly into the Host. It is located at the top of the Host and is activated by Barcode buttons on the sides of the Host. epoc_hardware_touchscreen.mp3 Touchscreen Layer: The epoc Host Application has a simple, intuitive user interface, similar to that of a smartphone. Navigate the epoc Host Application software as you would any touch screen device: • Tap on an item to select it. • Scroll down or up by swiping your finger along the screen. epoc_hardware_softreset.mp3 Soft Reset Layer: For a soft reset, press and hold the Power button for more than 2 seconds until a menu appears. Next, select Restart. The soft reset can be used to restart the Host application if the epoc Host stops functioning and/or responding. epoc_hardware_hardreset.mp3 Hard Reset Layer: If a soft reset does not help, you will need to perform a hard reset. To perform a hard reset, press and hold the Power button for more than 10 seconds until the device reboots. Hard Reset If a soft reset does not help, you will need to perform a hard reset. To perform a hard reset, press and hold the Power button for more than ten seconds until the device reboots. 5 Soft Reset For a soft reset, press and hold the Power button for more than two seconds until a menu appears. Next, select Restart. The soft reset can be used to restart the Host application if the epoc Host stops functioning and/or responding. 4 Touchscreen The epoc Host Application has a simple, intuitive user interface, similar to that of a smartphone. Navigate the epoc Host Application software as you would any touch screen device: Tap on an item to select it Scroll down or up by swiping your finger along the screen 3 Barcode Scanner The Barcode Scanner allows the user to scan text, such as a patient ID, directly into the Host. It is located at the top of the Host and is activated by Barcode buttons on the sides of the Host. 2 Rechargeable Battery The epoc Host contains a Lithium Ion rechargeable battery that is located inside the host. In order to charge the battery, the Host Cradle Blade, located on the bottom of the Host, must be inserted into the Docking Pivot located on the Reader. An LED charging indicator located on the top right corner of the Host shows when charging is in progress and when complete. Several hours may be required to fully recharge the battery. The Host can be operated normally while charging. 1 ? epoc Test Card The epoc single-use Test Card is comprised of an array of sensors on a sensor module mounted in a credit-card sized fluidic housing with a sample entry port and a sealed calibrator fluid reservoir. Select the tab arrows to learn more about the epoc single-use test card. Front of the epoc Test Card Back of the epoc Test Card Test Card Packaging Test Cards epoc_hardware_testcard.mp3 Base layer: The epoc single-use Test Card is comprised of an array of sensors on a sensor module mounted in a credit-card sized fluidic housing with a sample entry port and a sealed calibrator fluid reservoir. Select the tab arrows to learn more about the epoc single-use test card. epoc_hardware_frontofcard.mp3 Front of card layer: The front of the epoc single-use Test Card is comprised of four main components: Sensor module, test panel type, barcode and test card expiration date. Hover over the markers to identify the different parts of the front of the epoc single-use test card. epoc_hardware_backofcard.mp3 Back of card layer: The back of the single-use Test Card has six main components: measurement region, sensor surface, a sealed valve that is punctured once the card is entered into the card slot properly, a blood waste chamber, a sealed calibrator reservoir and a sample entry port. Hover over the markers to identify the different parts of the back of the epoc single-use test card. epoc_hardware_packaging.mp3 Packaging layer: Each single-use Test Card is packaged by the manufacturer into a card pouch which also contains one (1) strip of desiccant. A tear notch is used to open the pouch. Twenty-five (25) card pouches are packed into boxes of 25 cards. Quantities of 50 Card Boxes are packed into larger shipping cartons. epoc Test Card Packaging Each single-use Test Card is packaged by the manufacturer into a card pouch which also contains one (1) strip of desiccant. A tear notch is used to open the pouch. Twenty-five (25) card pouches are packed into boxes of 25 cards. Quantities of 50 Card Boxes are packed into larger shipping cartons. NOTE: Test cards with green labeling are packaged into a card pouch. Fifty (50) card pouches are packed into boxes of 50 cards. Quantities of 50 Card Boxes are packed into larger shipping cartons. Back of epoc Test Card The back of the single-use Test Card has six main components: Measurement region Sensor surface Sealed valve that is punctured once the card is entered into the card slot properly Blood waste chamber Sealed calibrator reservoir Sample entry port Select the markers on the right to learn more about the back of the epoc single-use Test Card. Measurement Region Sensor Surface Blood Waste Chamber Sealed Calibrator Reservoir Sealed Valve Sample Entry Port Front of epoc Test Card The front of the epoc single-use Test Card is comprised of four main components: Sensor module Test panel type Barcode Test Card expiration date Select the markers on the right to learn more about the front of the epoc single-use Test Card. Sensor module Barcode Test Card Expiration Date Test Panel Type ? Course Review Congratulations. You have completed the epoc® with NXS Host Hardware Overview online training course. Select the numbered buttons below to review the material before proceeding to the final assessment. Describe the components of the Test Card Identify the major components of the Host Identify the major components of the Reader 1 1 1 3 3 3 2 2 2 Course Review Major Components of The Test Card Front of the Test Card- sensor module, test panel type, barcode, expiration date Back of the Test Card- measurement region, sensor surface, sealed valve, blood waste chamber, sealed calibrator reservoir, sample entry port Test Card Packaging- Each single-use Test Card is packaged by the manufacturer into a card pouch which also contains one (1) strip of desiccant. A tear notch is used to open the pouch. Fifty (50) card pouches are packed into boxes of 50 cards. Quantities of 50 Card Boxes are packed into larger shipping cartons Major Components of The Host Rechargeable Battery- The epoc Host contains a Lithium Ion rechargeable battery that is located inside the host. In order to charge the battery, the Host Cradle Blade, located on the bottom of the Host, must be inserted into the Docking Pivot located on the Reader Barcode Scanner- The Barcode Scanner allows the user to scan text, such as a patient ID, directly into the Host. It is located at the top of the Host and is activated by Barcode buttons on the sides of the Host Touchscreen- The epoc Host Application has a simple, intuitive user interface, similar to that of a smartphone. Navigate the epoc Host Application software as you would any touch screen device: Tap on an item to select it, scroll down or up by swiping your finger along the screen Soft/Hard Reset- The epoc NXS Host can be reset by either choosing a soft or hard reset. Soft- press the power button for two seconds, next select Restart. Hard- press the power button for ten seconds until the Host reboots Major Components of The Reader Test Card Slot- Houses a card entry switch, barcode scanner, electrical contact for contacting the test card sensory module upon insertion. Also houses a thermal subsystem that heats the test cards measurement region to 37° C during a test Battery Status Indicator- Battery is fully charged when the indicator light is lit up a solid amber color. Battery is charging and powered on when the indicator light is flashing amber Test Status Indicator- Solid green indicates the Reader is ready to process a test card. Flashing green indicates the Reader is processing a test. Solid red indicates the Reader shows an error which needs to be resolved before processing any tests Power button- Lights up solid green when the Reader is powered on Docking Pivot- Provides a physical link between the epoc® Reader and Host. A pocket in the Docking Pivot accepts the blade section of the Host Cradle Disclaimer Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com ? Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start ? Assessment Select the best answer. ? Question 1 of 5 Which parts comprise the front of the Test Card? Sensor module, test panel type, barcode, expiration date Test panel type, barcode, expiration date, sensor surface Sensor module, expiration date, measurement region, barcode Multiple Choice Incorrect The measurement region is located on the back of the Test Card. Incorrect The sensor surface is located on the back of the Test Card. Incorrect Select the best answer. ? Question 2 of 5 How do you perform a soft reset on the NXS Host? Hold the power button for two seconds then select Restart Hold the power button for ten seconds until the Host reboots Power down the system, remove and re-install the battery, then power up the Host Multiple Choice Incorrect The battery cannot be removed from the NXS Host. Incorrect The power button does not need to be held for ten seconds in order to perform a soft reset. Incorrect Select the best answer. ? Question 3 of 5 What temperature does the thermal subsystem heat the Test Cards to? 37° C 28° C 41° C Multiple Choice Incorrect The thermal subsystem does not heat the Test Cards to 41° C. Incorrect The thermal subsystem does not heat the Test Cards to 28° C. Incorrect Select the best answer. ? Question 4 of 5 Which of the following is a component of the Test Card slot on the epoc Reader? Barcode Scanner Rechargeable Battery Docking Pivot Multiple Choice Incorrect The Docking Pivot is located on the back end of the epoc Reader. Incorrect The battery is not housed in the Test Card slot. Incorrect Select the applicable image. ? Where do you dock the epoc NXS Host? Question 5 of 5 Pick One Incorrect Incorrect The Reader is powered on and off by pressing the power button. Incorrect The Test Card is inserted into the card slot. Assessment Results YOUR SCORE: PASSING SCORE: Review Retry Retry Continue Continue Continue %Results.ScorePercent%% %Results.PassPercent%% ? Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the epoc® with NXS Host Hardware Overview Online Training. Completion Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the CC icon to display closed captioning (subtitles). Click Next to continue. Next Caption Icon add subtitles Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 HOOD05162003194495 | Effective Date: 07-JUN-2021 1.1 Welcome 1.2 epoc Reader 1.3 epoc Host 1.4 Test Cards 1.5 Course Review 1.6 Disclaimer 1.7 Assessment 1.14 Completion
- epoc
- nxs
- host
- reader
- hardware
- overview