GOKnee 3D
This Job Aid provides a short introduction of GOKnee 3D.
GoKnee 3D Job Aid GOKnee3D is a push-button, clinically validated, high-resolution 3D isotropic exam of the knee which takes 10 minutes (with MAGNETOM Skyra, total examination times will vary with system field strength with up to 11 minutes on MAGNETOM Aera). It provides essential clinical contrasts, PD-weighted and T2-weighted with fat suppression, and the 3D isotropic images can be reformatted to support image reading in all planes. Push-button functionality is enabled with AutoAlign Knee (available with the Large Joint Dot Engine), providing high consistency in imaging, helping to improve patient throughput and reduce costs per scan. By using CAIPIRINHA SPACE, GOKnee3D provides the following benefits: • CAIPI shift in the phase encode direction • Optimal use of coil sensitivity profile information • Improved parallel imaging reconstruction • Reduced aliasing artifacts and noise • High SNR with high acceleration You can find the GOKnee3D program in the Siemens tree by following the path knee > Knee Dot Engine > general 3D (see screenshot on the following page). Several 3D acceleration techniques including CAIPIRINHA SPACE sequence are available for multiple regions (hand, wrist, unilateral hip, foot, ankle, knee). CAIPIRINHA SPACE is Siemens unique and another viable option for fast MRCP scans in one single breath-hold. It enables significant 4-fold acceleration for 3D imaging. Dot Cockpit - Main ? O X Explorer Program Editor Browse Import Export Edit Simulate X SIEMENS SIEMENS » knee » Knee Dot Engine » general 3D Dot GOKnee3D @ Ortho Patient View Standard › neck soft tissue AAKnee_Scout_TxRx 00:14 AutoAlign Scout › thorax pd_space_sag_Iso 04:37 › heart MPR Assignment › breast t2_space_fs_sag_Iso 04:39 › abdomen O MPR Assignment > pelvis female MPR planning ... @ MPR Planning > pelvis male >tmj › shoulder › elbow › wrist › hand hip Knee Dot Engine general 20 general 30 lesion > library > clinical libraries › ankle › foot > whole body oncology > whole body diffusion > peripheral angiography spectroscopy Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 10 SEP 2020 | HOOD05162003113057 Healthineers Job Aid | GoKnee 3D Effective Date: 10 SEP 2020 | HOOD05162003113057 If you click on the second examination protocol of the program, a dialog box will open and show you the different parameters. When you select Protocol Parameters on the left side and the tab Resolution and Acceleration in the middle of the box, the Acceleration mode CAIPRINHA is selected with the Total factor 4. Dot Cockpit - Explorer Explorer Program Editor Browse Import Export Edit Simulate SIEMENS SIEMENS > knee > Knee Dot Engine > general 3D Dot GOKnee3D Ortho Patient View V Standard head AAKnee_Scout_TxRx 00:14 > c-spine AutoAlign Scout t-spine pd_space_sag_iso 04:37 I-spine MPR Assignment t2_space_fs_sag_iso 04:39 whole-spine ? X neck soft tissue SIEMENS >> knee >> Knee Dot Engine >> general 3D >> pd_space_sag_iso General 4:37 min 4 Auto @ 4 @ 0.5x0.5x0.5 mm3 1.00 >thorax Protocol Parameters Routine Contrast Resolution eometry System Physio Inline Sequence heart Voice Commands breast Execution Common Acceleration Filter abdomen Image Management Acceleration mode CAIPIRI ... pelvis female Auto Load CAIPIRINHA Phase Partial Fourier Off > pelvis male Copy References > tmj Preview Total Factor 4 - Slice Partial Fourier Off > shoulder eference Scans GRE/Sep ... elbow Acceleration Factor PE > wrist Reference Lines PE Elliptical Scanning M >hand Acceleration Factor 3D >hip 2 knee Reference Lines 3D 24 Knee Dot Engine Reordering Shift 3D general 2D general 3D lesion >library > clinical libraries Addin Configuration ... Close > ankle Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 10 SEP 2020 | HOOD05162003113057 Healthineers Page 2 of 4 Job Aid | GoKnee 3D Effective Date: 10 SEP 2020 | HOOD05162003113057 Independent from the GOKnee3D program, you can search in the Siemens tree for dedicated CAIPIRINHA SPACE protocols. In our example below, we search for Caipi Space – all relevant programs and examination protocols will be highlighted in yellow. Dot Cockpit - Explorer 2 0 x Explorer Program Editor Browse Import Export Simulate X SIEMENS .. > head >> library > 3D Q Caipi Space t1_space_sag_p2_iso 05:36 head [1] t1_space_sag_cs4_iso 03:27 Brain Dot Engine clinical libraries advanced applications libraries t2_space_sag_p3_iso 05:57 GOBrain library [1] t2_space_sag_p2_iso 03:49 localizer T1 t2_space_sag_cs4_iso 02:32 T2 PD+T2 3D [1] t2_space_dark-fluid_sag_p2_ns-t2p ... 05:52 diffusion perfusion t2_space_dark-fluid_sag_caipi4 04:21 BOLD t2_space_dark-fluid_sag_cs6_iso 03:46 BLADE SWI t2_space_dark-fluid_sag_cs5_highres 04:21 flow Head32 t1_space_ir_cor_p2_iso 05:30 QUIET StarVIBE SyMR dir_space_sag_p2_iso 06:24 MRF 06:32 angiography dir_space_sag_p2_1.2mm angiography ce dir_space_sag_cs7_1mm_iso 05:24 > c-spine >t-spine Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 10 SEP 2020 | HOOD05162003113057 Healthineers Page 3 of 4 Job Aid | GoKnee 3D Effective Date: 10 SEP 2020 | HOOD05162003113057 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively ‘Operator Manual’) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest versi on of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively ‘Functionality’) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 05 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 10 SEP 2020 | HOOD05162003113057 Healthineers Page 4 of 4
- go
- knee
- knee 3D
- go 3D
- mr 3D
- mr knee
- mr caipi
- caipi space
- mr space
- knee caipi
- knee space
- caipi 3D