How to Access and Adjust Dose Curves in CARE Dose 4D
How to Access and Adjust Dose Curves in CARE Dose 4D step by step
How to Access and Adjust Dose Curves in CARE Dose4D Computed Tomography Siemens' CARE Dose4D automatically adapts radiation dose to the size and shape of each individual patient. However, image quality is subjective, and as such the user/Radiologist may wish to further modulate dose for a particular body part or patient size population. The CARE Dose4D configuration curves allow the user more control over the mAs adaptation strength. 1. Access the CARE Dose4D configuration via Options > Configuration > Examination. Optons System Help Version License .... Life Card print number File Browser ... Switch to External Simulator Hide Simulation Taskcard Maintenance ... Configuration Service Notes DICOM X LTT Patient Patient Transfer Conversion Auto Delete Browser Registration Search Expert-4 Image Text Scan Protocol E-Logbook Examination Bolus Edtor Assistant Configuration Tracking Respiratory HeartView Intervention 30 Viewing Filming Study Layout Life cm Firming Filming Report DynEva CT Volume CT Update Layout Editor Configuration + . Audit Tra Software Add Printer Date and Regional and SR Viewer Dieenbution Time Examination CAP 2. Select the Dose tab. The CARE Dose4D configuration table can be seen on the right. Examination Configuration Patient Dose Workflow Processing Contrast Display Options CARE Dose4D configuration: mAs adaptation to patient size Dose notification CARE Profile Organ characteristics Chad Adult slim Adult obese Brain Average Average Average Exposed range Neck Average Average Average Shoulder Average Average Average Dose Report Thorax Average Average Average Abdomen Average Average Average Activate Dose Report Auto transfer Pelvis Average Average Average Additional transfer None Spine Average Average Average Osteo Average Average Average Dose Alert Head/Vascular Head Average Average Average Child Vascular Body Average Average Average Adult Runoff Average Average Average CTDIvol 1000 mGy 1000 mGy Cardio Average Average Average mGy cm Respiratory Average Average Average DLP mGy cm OK Apply Default Settings Cancel Help SIEMENS siemens.com/healthineers Healthineers . Job Aid | How to Access and Adjust Dose Curves in CARE Dose4D Effective Date: 5/15/2016 | Quality 334 3. CARE Dose4D dose adaptation strength can be set individually for the various organ characteristics ... Examination Configuration Patient Dose Workflow Topogram Processing Contrast Display Options CARE Dose4D configuration: mAs adaptation to patient size Dose notification CARE Profile Organ characteristics Child Adult slim Adult obese Brain Average Average Average Exposed range MI Neck Average Average Average Shoulder Average Average Average Dose Report Thorax Average Average Average Abdomen Average Average Average Activate Dose Report Auto transfer Pelvis Average Average Average Additional transfer None Spine Average Average Average Osteo Average Average Average Average Average Average Dose Alert Head/Vascular Head Child Vascular Body Average Average Average Adult Runoff Average Average Average CTDIvol 10002 mGy 1000mGy Cardio Average Average Average Average Average DLP mGy cm mGy*cm Respiratory Average OK Apply Default Settings Cancel Help ... or various patient sizes (Child, Adult slim, Adult obese). Examination Configuration Patient Dose Workflow Topogram Processing Contrast Display Options CARE Dose4D configuration: mAs adaptation to patient size Dose notification M CARE Profile Organ characteristics Child Adult slim Adult obese Brain Average Average Average Exposed range Neck Average Average Average Shoulder Average Average Average Dose Report Thorax Average Average Average Abdomen Average Average Average Activate Dose Report Auto transfer Pelvis Average Average Average Additional transfer None Spine Average Average Average Osteo Average Average Average Head/Vascular Head Average Average Average Dose Alert Child Vascular Body Average Average Average Adult Runoff Average Average Average CTDIvol 1000 mGy 1000 mGy Cardio Average Average Average mGy*cm mGy*cm Respiratory Average Average Average DLP OK Apply Default Settings Cancel Help 4. In the selection list, select a CARE Dose4D adaptation strength. You can choose from Very Weak, Weak, Average, Strong and Very Strong. The setting of the adaptation strength is effective for all protocols with CARE Dose4D. Examination Configuration Patient Dose Workflow Topogram Processing Contrast Display Options CARE Dose4D configuration: mAs adaptation to patient size Dose notification CARE Profile Organ characteristics Child Adult slim Adult obese Brain Average Average Average Exposed range VI Neck Average Average Average Shoulder Average Average Average Dose Report Thorax Average Average Average Abdomen Average Average Average Activate Dose Report v Auto transfer Pelvis Average Very weak Average Spine Average Weak Additional transfer None Average Average Osteo Average Strong Average Head/Vascular Head Average Very strong Average Dose Alert Vascular Body Average Average Average Adult Child Runoff Average Average Average CTDIvol 1000 mGy 1000 mGy Cardio Average Average Average Average DLP mGy*cm mGy cm Respiratory Average Average Apply Default Settings Cancel Help QK Siemens Healthineers Services Page 2 of 4 Job Aid | How to Access and Adjust Dose Curves in CARE Dose4D Effective Date: 5/15/2016 | Quality 334 5. The adaptation curves govern how aggressively CARE Dose4D modulates the dose away from/towards Average based on an individual patient's size. Tube current (eff. mAs) t very strong strong average weak very weak Quality ref. mAs Reference point (adult) + Attenuation Reference patient (70-80 kg) EXAMPLE: If all abdominal images of obese patients are too noisy, select a stronger CARE Dose4D curve in the Adult obese column for the Abdomen Organ Characteristic. This will enable CARE Dose4D to modulate stronger/more (increasing the dose) for abdomens on obese patients. EXAMPLE: If all abdominal images of children are too noisy, select a weaker CARE Dose4D curve in the Child column for the Abdomen Organ Characteristic. This will enable CARE Dose4D to modulate weaker/less (increasing the dose) for abdomens on child patients. Siemens Healthineers Services Page 3 of 4 Job Aid | How to Access and Adjust Dose Curves in CARE Dose4D Effective Date: 5/15/2016 | Quality 334 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 4 of 4
- truepoint
- mct
- mct 20 excel
- as
- flash. symbia T