How to Configure Limits for CARE kV
How to Configure Limits for CARE kV Computed Tomography Siemens’ CARE kV automatically suggests a kV setting for each individual patient, specific to their size and the type of examination being performed, in order to optimize both dose and image quality. For individual scan ranges, certain kV values can be excluded if the CARE kV limits are set. These limits can be configured in the Scan Protocol Assistant. For example – kV limits could be applied if the user did not wish to have CARE kV use 140kV on vascular/CTA examinations or 80kV on head examinations. 1. Open the Scan Protocol Assistant from the Insert View Setup Image Options System Help Version top of the screen: Options > Configuration > License. Scan Protocol Assistant. File Browser SOMATOM LifeNet Maintenance Report Conversion e-Logbook Auto Expose Configuration Configuration Configuration Service Osteo CT Neuro PCT Scan Protocol Assistant Scan Protocol Assistant 2. Select Change Parameters and click the Next icon at the bottom. Select the protocols for which you wish to configure CARE kV limits. Scan Protocol Assistant X 2 3 4 5 What do you want to do? 2 4 5 W Select the scan protocols you want to change Scan protocols Manipulate scan protocols (cut / copy / paste / delete) O adult @ child . Change parameters Head Select all - Spine Selected Child Prot HeadRoutine - C-Spine Head HeadSeq Osteo Head Routine Import user scan protocols InnerEarHR SpineRoutine Head Seq InnerEarSeqHR SpineSeq InnerEarHR Dental Osteo InnerEarSecHR Dental Export scan protocols Vascular - Neck -Thorax protocol a Neck protocol a protocol a protocolb protocol a . Restore scan protocols to Siemens default protocol b protocol b protocol c protocol b Shoulder - protocol c protocol d Shoulder protocol d protocol e protocol a protocol a protocol b protocol b - Abdomen specials Arms protocol a protocol a protocol a Contrast protocols · Define contrast protocols Arms protocol b protocol b protocol b protocol a protocol c protocol c protocol b protocol d protocol d Legs protocol a List / import / export contrast protocols Legs protocol e protocol e protocol b protocol a - POMs Vascular protocol b protocol a protocol a protocol b protocol b protocol c protocol c protocol d Back Next > Qut Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 11/08/2018 | HOOD/HILS HOOD05162002966200 Job Aid | How to Configure Limits for CARE kV Effective Date: 11/08/2018 | HOOD/HILS HOOD05162002966200 3. On the Scan step, minimum and 2 3 4 5 maximum kV val- Change parameters ..... ues can be en- tered for each de- Protocol Topogram Scan Recon Auto tasking Trigger Intervention Contrast Including topogram sired acquisition Range name art art time | Bolus trigger level | CTDIvol tx-CARE| Uppe | LO. | Dose Notification CTDIVOI Dose Notification DLP max. kv min. KV CARE K for which CARE Abdomen / AbdMultiPhase (Adult) Topogram: 35mA, 512mm, AP, Craniocaudal kV is enabled. Non Cont ... itton 5.15 12.6396 Arterial ... itton 5.15 14.1685 20 25 140 140 80 On Venou ... 5.15 12.6396 140 888 M Select al Sequence scans Spiral scans Multiscans Interventional scans Adaptive 4D spiral scans i-Sequence i-Spiral i-Fluoro CARE Dose type CARE D4D FAST Adjust Dose modulation v Upper limit max. scan time 20.0 s CARE KV -On Lower limit max. mAs 25 % Quality ref. mAs 190 Dose Notification CTDIvol Eff. mA 190 Ref. kV 120 DLP kV 120 CARE KV min. kV -80 Dose saving optimized for: max. kV 140 Dose Parameter 4. Jump to Step 4 > Confirmation. Click the Yes icon to save the changes Scan Protocol Assistant X Do you want to save these changes? 2 3 4 5 Confirmation Yes Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 3 Job Aid | How to Configure Limits for CARE kV Effective Date: 11/08/2018 | HOOD/HILS HOOD05162002966200 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 3
- How to Configure Limits for CARE kV