How to Create ROI Findings and Save Results in View&GO
This job aid guides you through the process of creating ROI findings and saving the results in View&Go.
How to create ROI findings and save results in View&GO Somaris X; SOMATOM go. or SOMATOM X. scanners 1. From the Patient Browser, load desired series into View&GO by right mouse button clicking on the series from the menu, choosing Open with, and then CT View&GO. This can also be done by clicking on the View&GO icon in the tool bar to the upper right. Patient Browser Local Data + arch by Name, ID. Date, Description and Modality (Guter)| Q More Filters Fin DICOU 14 IT Results (14 results, 6:20:39 PM) Series Patient Modality Study Date and T ... Y Study Descript ... Exported Study Archived ACR Testing *11/18/1858. O 2021.05.10-17 42:58-DST-1.3.12.2.1107 5.1.7 Open View as Read-Only Open with Favorites View as Read Only with Suggested Set Delete Protection state CT CaScoring Set Archive state CT Dental Correct CT Dual Energy ... x Cut CT Neuro Perfusion Paste CT View&GO Delete Del MM RT Image Suite › More Instances Manage Raw Data 2. From the Favorite Tools menu or right upper segment menu of the image, select ROI Cir- cle and draw ROI via left mouse button. CT View&GO Distance Line ROI Cde O ACR Testing 2021.05.10-17:42:58-DST-1.3.12.2.1107.5.1.7 Prcel Lers "11/18/1858, O, 162Y NOW CURRENT 5/10/2021 Marker Abdomen 5.00 Br40 A3 [1] Argle #AC_6c3c06666ddc4 Text 6.17:38.73 PM HA SPI 100 1 IMA 19 SP F720.0 Favorite Tools 3D 10cm Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/04/2021 | HOOD05162003194967 Healthineers Job Aid | Create ROI findings & save results in View&GO Effective Date: 06/04/2021 | HOOD05162003194967 Note: To duplicate ROIs for size consistency, right mouse button click on ROI. Select Copy Measurement. Next, place mouse cursor over desired location for new ROI. Right mouse but- ton click and select Paste to the cursor position. Min/ Man: - 1024 HLV- 1024 HIJ O ROI Cicle Mean /3D -1024 HUNO HU Area: 2.43 cm2 30 Reference Point Distance Line is Marker OPaste to the cursor position Delete Measurement opy Measurement Show in 30 3. After ROIs are created, save results from Favorite Tools by clicking on icon Save as Series. This can also be done by clicking in the upper left segment menu of the image. CT View&GO Zoom/Pan Windowing Rotate 242.58-DST-13:12.2.110 Scroll 0. 162Y DH Movie 30 Reference Poor [ 1] Min / Maxc O HUYO HU Meany/SD. 0 HUNO HU Area: 3.34 cm2 Ranges: 36ddc4 Save as Series Fit to Segment Save as Series Series Name images with ROls Image Comment Accept Cancel Favorite Tools C Min / Max O HUND HU 3D Mean/SD 0 HUVO HU Area: 21.49 cm2 Snapshot Export 50 4. Export series from the Favorite Tools by choosing icon, or by right mouse button click on right hand menu under series navigator and choosing Export Series. Abdomen 5.00 Br41 Export Data LAC_<3<00668k 6 17:38.73 PM CDOVO SPI 100 1 IVA 19 Espon Series SP F720.0 Congresa Create DOOM Favorite Tools O Area 21:49 5m2 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 4 Job Aid | Create ROI findings & save results in View&GO Effective Date: 06/04/2021 | HOOD05162003194967 5. To save and populate results on the Patient Browser, select Save and Send or Save option. This can be done by selecting the icons on the left panel in the CT View&Go tab, or by closing the patient from View&GO. Close Patient ? × How would you like to close the patent Meyer, Lea? Save ard Send R Tools X Save ard Pause 3D x Descard Changes Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 4 Job Aid | Create ROI findings & save results in View&GO Effective Date: 06/04/2021 | HOOD05162003194967 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquar- ters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 4
- acr
- somatom go
- roi